Mitsubishi Lancer Evolution 7. Manual — part 112
CIRCUIT DIAGRAMS
B-179
HEATER AND MANUAL AIR CONDITIONER (See P.B-174,180.)
OPERATION
<Blower motor control>
D
When the ignition switch is turned “ON”, the
blower relay is energized. If the blower switch
is turned “ON” (LO, ML, MH, or HI position)
in this condition, the blower is activated through
the circuit via resistor at a speed corresponding
to the blower switch position.
TROUBLESHOOTING HINTS
<Blower motor control>
1. Blower motor is energized at one switch position
and not energized at another.
D
Check resistor.
D
Check blower switch.
2. Blower motor is energized only when switch
is positioned in HI.
D
Check resistor.
CIRCUIT DIAGRAMS
B-180
HEATER AND MANUAL AIR CONDITIONER
R.H. drive vehicles
CIRCUIT DIAGRAMS
B-181
CIRCUIT DIAGRAMS
B-182
HEATER AND MANUAL AIR CONDITIONER <R.H. drive vehicles> (CONTINUED)