Mitsubishi Evolution X. Manual — part 586
DIAGNOSIS
TSB Revision
KEYLESS OPERATION SYSTEM (KOS)
42B-251
STEP 3. Using scan tool MB991958, check pulse check.
Check the signals related to the keyless entry system opera-
tion.
CAUTION
To prevent damage to scan tool MB991958, always turn the
ignition switch to the "LOCK" (OFF) position before con-
necting or disconnecting scan tool MB991958.
(1) Connect scan tool MB991958. Refer to "How to connect the
Scan Tool (M.U.T.-III)
(2) Confirm the ETACS pulse check.
• Remove the ignition key from the ignition key cylinder.
OK: The scan tool (M.U.T.-III) tone alarm sounds.
Q: Is the check result normal?
YES : Go to Step 4.
NO : Refer to "Signals from transmitter switches are not
received
."
STEP 4. Check trunk lid latch connector F-19 and
ETACS-ECU connector C-311 for loose, corroded or
damaged terminals, or terminals pushed back in the
connector.
Q: Is trunk lid latch connector F-19 and ETACS-ECU
connector C-311 in good condition?
YES : Go to Step 5.
NO : Repair or replace the damaged component(s). Refer
to GROUP 00E, Harness Connector Inspection
Item name
Conditions
Transmitter switch
Turn the switch ON/OFF.
AC608435
Data link connector
MB991827
MB991824
MB991910
AB
DIAGNOSIS
TSB Revision
KEYLESS OPERATION SYSTEM (KOS)
42B-252
STEP 5. Check the trunk lid latch assembly.
Remove the trunk lid latch assembly. Refer to GROUP 42A,
Trunk lid removal and installation
Q: Is the trunk lid actuator normal?
YES : Go to Step 6.
NO : Replace the trunk lid latch assembly.
STEP 6. Check the ground circuit to the trunk lid lock
actuator. Measure the resistance at trunk lid lock actuator
connector F-19.
(1) Disconnect trunk lid lock actuator connector F-19 and
measure the resistance available at the wiring harness side
of the connector.
(2) Measure the resistance value between terminal 2 and
ground.
• The resistance should be 2 ohms or less.
Q: Is the measured resistance 2 ohms or less?
YES : Go to Step 9.
NO : Go to Step 7.
Lever position
Battery
connection
Lever operation
At the "OFF"
position
• Connect
terminal No.2
and the
negative
battery
terminal.
• Connect
terminal No.3
and the
positive battery
terminal.
The lever moves
from the "OFF"
position to the
"OPEN" position.
AC609215
AB
Off
Lever
Open
AC209731
Connector F-19
(harness side)
AC208731CD
DIAGNOSIS
TSB Revision
KEYLESS OPERATION SYSTEM (KOS)
42B-253
STEP 7. Check the wiring harness between the trunk lid
latch connector F-19 (terminal No. 2) and the ground for
open circuit.
(1) Disconnect trunk lid latch connector F-19 and ground, and
check the wiring harness.
(2) Check the wiring harness between trunk lid latch connector
F-19 (terminal No. 2) and ground.
OK: Continuity exists (2
Ω or less)
Q: Is the wiring harness between trunk lid latch connector
F-19 (terminal No. 2) and ground in good condition?
YES : Go to Step 8.
NO (trunk lid latch connector F-19 terminal No. 2
−
ground.) : Repair the wiring harness between trunk lid latch
connector F-19 (terminal No. 2) and ground.
STEP 8. Check the wiring harness between the trunk lid
latch connector F-19 (terminal No. 2) and the ground for
short circuit.
(1) Disconnect unlock sensor (front door: RH) connector E-05,
and check the wiring harness.
(2) Check the wiring harness between trunk lid latch connector
F-19 (terminal No. 2) and ground
OK: No continuity
Q: Is the wiring harness between trunk lid latch connector
F-19 (terminal No. 2) and the ground in good condition?
YES : Go to Step 11.
NO (trunk lid latch connector F-19 terminal No. 2
−
ground.) : Repair the wiring harness between trunk lid latch
connector F-19 (terminal No. 2) and ground.
STEP 9. Check the wiring harness between the trunk lid
latch connector F-19 (terminal No. 3) and the ETACS-ECU
connector C-311 (terminal No. 1) for open circuit.
(1) Disconnect trunk lid latch connector F-19 and ETACS-ECU
connector C-311, and check the wiring harness.
(2) Check the wiring harness between trunk lid latch connector
F-19 (terminal No. 3) and ETACS-ECU connector C-311
(terminal No. 1).
OK: Continuity exists (2
Ω or less)
Q: Is the wiring harness between trunk lid latch connector
F-19 (terminal No. 3) and ETACS-ECU connector C-311
(terminal No. 1) in good condition?
YES : Go to Step 10.
NO (trunk lid latch connector F-19 terminal No. 3
−
ETACS-ECU connector C-311 terminal No. 1.) : Repair
the wiring harness between trunk lid latch connector
F-19 (terminal No. 3) and ETACS-ECU connector
C-311 (terminal No. 1).
AC209731
Connector F-19
(harness side)
AC208731CD
AC209731
Connector F-19
(harness side)
AC208731CD
AC709707HP
Harness side: F-19
Harness side: C-311
DIAGNOSIS
TSB Revision
KEYLESS OPERATION SYSTEM (KOS)
42B-254
STEP 10. Check the wiring harness between the trunk lid
latch connector F-19 (terminal No. 3) and the ground for
short circuit.
(1) Disconnect trunk lid latch connector F-19, and check the
wiring harness.
(2) Check the wiring harness between trunk lid latch connector
F-19 (terminal No. 3) and ground
OK: No continuity
Q: Is the wiring harness between trunk lid latch connector
F-19 (terminal No. 3) and the ground in good condition?
YES : Go to Step 11.
NO (trunk lid latch connector F-19 terminal No. 3
−
ground.) : Repair the wiring harness between trunk lid latch
connector F-19 (terminal No. 3) and ground.
STEP 11. Check of the troubles
Operate the transmitter and check that the trunk lid can be
opened.
Q: Is the check result normal?
YES : The diagnosis is complete.
NO : Replace the ETACS-ECU. When the ETACS-ECU is
replaced, register the keyless ID. Refer to
The trunk lid can be opened by means of the
transmitter.
AC209731
Connector F-19
(harness side)
AC208731CK