Mitsubishi Evolution X. Manual — part 439

DIAGNOSIS <TC-SST>

TSB Revision

TWIN CLUTCH- SPORTRONIC SHIFT TRANSMISSION (TC-SST)

22C-213

STEP 2. Check whether the DTC is reset.
Q: Is DTC No. P186C set?

YES : Replace the TC-SST assembly. (Refer to

P.22C-341

.)

NO : Intermittent malfunction. (Refer to GROUP 00

− How

to Cope with Intermittent Malfunction

P.00-15

.)

DTC P186D: High side 1 system (Voltage low range out)

CAUTION

If there is any problem in the CAN bus lines,

an incorrect diagnostic trouble code may be
set. Prior to this diagnosis, diagnose the CAN
bus lines.

Whenever the ECU is replaced, ensure that

the CAN bus lines are normal.

.

DIAGNOSTIC FUNCTION

TC-SST-ECU checks that the high side 1 circuit is
normal.

.

DESCRIPTIONS OF MONITOR METHODS

The voltage of the high side 1 circuit is determined to
be too low.

.

MONITOR EXECUTION

• Continuous

.

MONITOR EXECUTION CONDITIONS
(OTHER MONITOR AND SENSOR)

Other Monitor (There is no temporary DTC stored

in memory for the item monitored below)

• P0758: Shift select solenoid 2 system (Open cir-

cuit)

• P0976: Shift select solenoid 2 system (Short to

ground)

• P0977: Shift select solenoid 2 system (Short to

power supply)

• P0746: Line pressure solenoid system (Drive cur-

rent range out)

• P0960: Line pressure solenoid system (Open cir-

cuit)

• P0961: Line pressure solenoid system (Overvolt-

age)

• P0962: Line pressure solenoid system (Short to

ground)

• P0963: Line pressure solenoid system (Short to

power supply)

• P0968: Shift/cooling switching solenoid system

(Open circuit)

• P0970: Shift/cooling switching solenoid system

(Short to ground)

• P0971: Shift/cooling switching solenoid system

(Short to power supply)

Sensor (The sensor below is determined to be

normal)

• Shift select solenoid 2

• Line pressure solenoid

• Shift/cooling switching solenoid

.

DIAGNOSIS <TC-SST>

TSB Revision

TWIN CLUTCH- SPORTRONIC SHIFT TRANSMISSION (TC-SST)

22C-214

LOGIC FLOW CHARTS (Monitor Sequence)

.

DTC SET CONDITIONS

Check Conditions

• Voltage of battery: 8 V or more.

• Voltage of battery: 16.5 V or less.

• Engine speed: 500 r/min or more.

• Time since above engine condition: 400 millisec-

ond or more.

• FET (Field Effect Transistor) of high side 1:

Switched off.

JUDGMENT CRITERIA

• FET output: 100 mV or less. (5 seconds)

.

OBD-II DRIVE CYCLE PATTERN

The FET channel output remains 100 mV or more for
5 seconds.

.

PROBABLE CAUSES

• Malfunction of TC-SST-ECU

DIAGNOSTIC PROCEDURE

STEP 1. Scan tool CAN bus diagnostics
Using scan tool MB991958, diagnose the CAN bus lines.
Q: Is the check result normal?

YES : Go to Step 2.
NO : Repair the CAN bus lines. (Refer to GROUP 54C

Troubleshooting

P.54C-14

.) After repairing the CAN

bus line, go to Step 2.

AC710728

START

No

Good

Malfunction

END

Continuous failure
for 5 sec

No

Yes

Yes

Monitoring condition met

Yes

No

FET* output < 100 mV

*FET : Field Effect Transistor

DIAGNOSIS <TC-SST>

TSB Revision

TWIN CLUTCH- SPORTRONIC SHIFT TRANSMISSION (TC-SST)

22C-215

STEP 2. Check whether the DTC is reset.
Q: Is DTC No. P186D set?

YES : Replace the TC-SST assembly. (Refer to

P.22C-341

.)

NO : Intermittent malfunction. (Refer to GROUP 00

− How

to Cope with Intermittent Malfunction

P.00-15

.)

DTC P186E: High side 2 system (Voltage low range out)

CAUTION

If there is any problem in the CAN bus lines,

an incorrect diagnostic trouble code may be
set. Prior to this diagnosis, diagnose the CAN
bus lines.

Whenever the ECU is replaced, ensure that

the CAN bus lines are normal.

.

DIAGNOSTIC FUNCTION

TC-SST-ECU checks that the high side 2 circuit is
normal.

.

DESCRIPTIONS OF MONITOR METHODS

The voltage of the high side 2 circuit is determined to
be too low.

.

MONITOR EXECUTION

• Continuous

.

MONITOR EXECUTION CONDITIONS
(OTHER MONITOR AND SENSOR)

Other Monitor (There is no temporary DTC stored

in memory for the item monitored below)

• P0776: Clutch cooling flow solenoid system

(Drive current range out)

• P0777: Clutch cooling flow solenoid system

(Stuck)

• P0964: Clutch cooling flow solenoid system

(Open circuit)

• P0965: Clutch cooling flow solenoid system

(Overvoltage)

• P0966: Clutch cooling flow solenoid system

(Short to ground)

• P0967: Clutch cooling flow solenoid system

(Short to power supply)

• P2718: Clutch/shift pressure solenoid 1 system

(Open circuit)

• P2719: Clutch/shift pressure solenoid 1 system

(Overcurrent)

• P2720: Clutch/shift pressure solenoid 1 system

(Short to ground)

• P2721: Clutch/shift pressure solenoid 1 system

(Short to power supply)

• P2733: Clutch/shift switching solenoid 1, spool

stuck

• P2736: Clutch/shift switching solenoid 1 system

(Open circuit)

• P2738: Clutch/shift switching solenoid 1 system

(Short to ground)

• P2739: Clutch/shift switching solenoid 1 system

(Short to power supply)

• P181B: Clutch 1 (Pressure low range out)

• P181C: Clutch 1 (Pressure high range out)

• P1859: Disengagement too late with clutch 1

Sensor (The sensor below is determined to be

normal)

• Clutch cooling flow solenoid

• Clutch/shift pressure solenoid 1

• Clutch/shift switching solenoid 1

.

DIAGNOSIS <TC-SST>

TSB Revision

TWIN CLUTCH- SPORTRONIC SHIFT TRANSMISSION (TC-SST)

22C-216

LOGIC FLOW CHARTS (Monitor Sequence)

.

DTC SET CONDITIONS

Check Conditions

• Voltage of battery: 8 V or more.

• Voltage of battery: 16.5 V or less.

• Engine speed: 500 r/min or more.

• Time since above engine condition: 400 millisec-

ond or more.

• FET (Field Effect Transistor) of high side 2:

Switched off.

JUDGMENT CRITERIA

• FET output: 100 mV or less. (5 seconds)

.

OBD-II DRIVE CYCLE PATTERN

The FET channel output remains 100 mV or more for
5 seconds.

.

PROBABLE CAUSES

• Malfunction of TC-SST-ECU

DIAGNOSTIC PROCEDURE

STEP 1. Scan tool CAN bus diagnostics
Using scan tool MB991958, diagnose the CAN bus lines.
Q: Is the check result normal?

YES : Go to Step 2.
NO : Repair the CAN bus lines. (Refer to GROUP 54C

Troubleshooting

P.54C-14

.) After repairing the CAN

bus line, go to Step 2.

AC710728

START

No

Good

Malfunction

END

Continuous failure
for 5 sec

No

Yes

Yes

Monitoring condition met

Yes

No

FET* output < 100 mV

*FET : Field Effect Transistor

Была ли эта страница вам полезна?
Да!Нет
Большое спасибо!
Ваше мнение очень важно для нас.

Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.

Текст

Политика конфиденциальности