Mitsubishi Outlander XL. Manual — part 308
ZK603636 AA00
Knock sensor 2
B-20 (B)
Connector: B-20
ZK603591
ECM
B-10 (GR)
Connector: B-10
AA00
CIRCUIT OPERATION
⦆
The knock sensor (terminal No. 1) sends a signal
voltage to the ECM (terminal No. 28).
⦆
The ground terminal (terminal No. 2) is grounded
with ECM (terminal No. 29).
TECHNICAL DESCRIPTION
⦆
The ECM applies 5 V from the ground terminal side
to judge a malfunction in the knock sensor circuit.
⦆
The ECM judges whether the knock sensor signal
circuit has a short circuit to the ground or an open
circuit by checking the input voltage from the knock
sensor.
⦆
When the knock sensor output voltage is below the
reference voltage, it is judged that a malfunction
exists.
DTC SET CONDITIONS
Check Condition
⦆
2 seconds or more have passed since the engine
starting sequence was completed.
Judgement Criterion
⦆
Knock sensor 2 output voltage has continued to be
lower than 0.5 volt for 2 seconds.
TROUBLESHOOTING HINTS (The most likely
causes for this code to be set are:)
⦆
Knock sensor 2 failed.
⦆
Harness damage.
⦆
Connector damage.
⦆
ECM failed.
DIAGNOSIS
Required Special Tools:
⦆
MB991958: Scan Tool (M.U.T.-III Sub Assembly)
⦆
MB991824: V.C.I.
⦆
MB991827: USB Cable
⦆
MB991910: Main Harness A
STEP 1. Check harness connector B-20 at the knock sensor
2 and harness connector B-10 at ECM for damage.
Q:Is the harness connector in good condition?
MULTIPORT INJECTION SYSTEM (MFI) <DIAGNOSIS>
13Ab-427
DIAGNOSTIC TROUBLE CODE PROCEDURES
YES:
Go to Step 2.
NO:
Repair or replace it. Refer to GROUP 00E, Harness
Connector Inspection P.00E-2. Then go to Step 4.
STEP 2. Check for short circuit to ground between knock
sensor 2 connector B-20 and ECM connector B-10.
ZK604050
B-20 harness
connector:
component side
AA00
1
2
(1)
Disconnect the connector B-20 and B-10 measure at the
harness side.
(2)
Check for the continuity between connector B-20 (terminal
No. 1) and ground.
⦆
Not continuity.
Q:Is the harness wire in good condition?
YES:
Go to Step 3.
NO:
Repair it. Then go to Step 4.
STEP 3. Replace the knock sensor 2.
ZC501967
AC404789
ZC5019680000
MB991824
MB991827
MB991910
Data link
connector
(1)
Replace the knock sensor 2.
To prevent damage to scan tool MB991958, always turn
the ignition switch to the "LOCK" (OFF) position before
connecting or disconnecting scan tool MB991958.
(2)
Connect scan tool MB991958 to the data link connector.
(3)
Turn the ignition switch to the "ON" position.
(4)
Erase the DTC.
(5)
Start the engine, and leave it idling for more than 2 seconds.
Then stop the engine.
(6)
After completing the test drive, read the DTC.
(7)
Turn the ignition switch to the "LOCK" (OFF) position.
Q:Is DTC P0332 set?
YES:
Replace the ECM. When the ECM is replaced, register
the ID code. Refer to GROUP 42B, ID Code Registration
Judgment Table <Vehicles with KOS> P.42B-12or GROUP
42C, ID Code Registration Judgment Table <Vehicles with
WCM> P.42C-8.
NO:
The inspection is complete.
STEP 4. Using scan tool MB991958, read the diagnostic
trouble code (DTC).
(1)
Turn the ignition switch to the "ON" position.
(2)
Start the engine, and leave it idling for more than 2 seconds.
Then stop the engine.
(3)
After completing the test drive, read the DTC.
(4)
Turn the ignition switch to the "LOCK" (OFF) position.
Q:Is DTC P0332 set?
YES:
Retry the troubleshooting.
NO:
The inspection is complete.
13Ab-428
MULTIPORT INJECTION SYSTEM (MFI) <DIAGNOSIS>
DIAGNOSTIC TROUBLE CODE PROCEDURES
DTC DTC P0333: Knock Sensor Circuit High (Bank 2)
M11310100372USA0000010000
ZK602867
1
2
3 4 5 6 7 8 9 10 11 12 13 14 15 16
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64
2
1
KNOCK SENSOR 2 CIRCUIT
KNOCK SENSOR 2
B-10
28
WHITE
BL
A
C
K
29
1
2
ENGINE
CONT RO L
MODULE
AA00
B-20
MU802601
MULTIPORT INJECTION SYSTEM (MFI) <DIAGNOSIS>
13Ab-429
DIAGNOSTIC TROUBLE CODE PROCEDURES
ZK603636 AA00
Knock sensor 2
B-20 (B)
Connector: B-20
ZK603591
ECM
B-10 (GR)
Connector: B-10
AA00
CIRCUIT OPERATION
⦆
The knock sensor (terminal No. 1) sends a signal
voltage to the ECM (terminal No. 28).
⦆
The ground terminal (terminal No. 2) is grounded
with ECM (terminal No. 29).
TECHNICAL DESCRIPTION
⦆
The ECM applies 5 V from the ground terminal side
to judge a malfunction in the knock sensor circuit.
⦆
The ECM judges whether the knock sensor signal
circuit has a short circuit to the ground or an open
circuit by checking the input voltage from the knock
sensor.
⦆
When the knock sensor output voltage is below the
reference voltage, it is judged that a malfunction
exists.
DTC SET CONDITIONS
Check Conditions
⦆
2 seconds or more have passed since the engine
starting sequence was completed.
Judgement Criterion
⦆
Knock sensor 2 output voltage has continued to be
higher than 2.25 volts for 2 seconds.
TROUBLESHOOTING HINTS (The most likely
causes for this code to be set are:)
⦆
Knock sensor 2 failed.
⦆
Harness damage.
⦆
Connector damage.
⦆
ECM failed.
13Ab-430
MULTIPORT INJECTION SYSTEM (MFI) <DIAGNOSIS>
DIAGNOSTIC TROUBLE CODE PROCEDURES
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.