Mitsubishi Outlander XL. Manual — part 1341
GROUP 55
HEATER, AIR CONDITIONING AND
VENTILATION
CONTENTS
GENERAL DESCRIPTION. . . .
HEATER UNIT. . . . . .
HEATER CONTROL. . . . ..
A/C COMPRESSOR. . . . ..
A/C-ECU. . . . . . .
DUCT. . . . . . ...
VENTILATION SYSTEM. . . .
55-1
GENERAL DESCRIPTION
M25501000001USA0000010000
The blower, heater, and evaporator have been
integrated with the heater and A/C system to achieve
a greater fan power and noise reduction. Manual A/C
is installed on LS models; automatic A/C is installed
on XLS models.
FEATURES
IMPROVEMENTS IN COMFORT
⦆
The outside/inside air circulation switching, air
outlet, and outlet air temperature are automatically
controlled according to the ambient temperature,
solar radiation, and passenger compartment
temperature so that the optimum air conditioning
has been achieved. <Automatic A/C>
⦆
By the adoption of clean air filter, the air quality
inside the passenger compartment has been
improved.
IMPROVEMENTS IN OPERATION
PERFORMANCE
⦆
Operability has been improved by the adoption of
large triple dial.
⦆
Customize function has been added for the
improved convenience.
IMPROVEMENTS IN FUEL ECONOMY
⦆
The high efficiency compressor with a 2-step profile
oil separator has been installed, thus improving the
fuel economy.
⦆
The idle-up speed is controlled in two steps to
secure the air cooling performance during summer
and to improve the fuel economy in the seasons
with moderate temperature.
⦆
Improvement of fuel economy by the cooling fan
control depending on the refrigerant pressure and
vehicle speed.
GLOBAL ENVIRONMENT PROTECTION
⦆
New refrigerant system (HFC134a) has been
adopted.
⦆
By the optimization of A/C system, the refrigerant
charging amount has been reduced.
⦆
Clean air filter media and its cover are separated to
reduce waste materials.
IMPROVEMENTS IN SERVICE QUALITY
⦆
Reduction of refrigerant gas leakage and
improvement in serviceability by incorporating
condenser and receiver
⦆
Clean air filter is installed to the backside of glove
box to facilitate the filter replacement.
IMPROVEMENTS IN RESPONSIBILITY
Reliable information transmission is achieved by
connecting A/C-ECU and each ECU via CAN
communication.
SPECIFICATIONS
Item
Specification
Air conditioning switch type
Rotary type
Compressor type
MSC90CAS
Cooling output
5.5 kW
Heating output
5.7 kW
Refrigerant
Type
R134a (HFC-134a)
Charge quantity g (oz)
480 - 520 (16.9 - 18.3)
CONSTRUCTION DIAGRAM
55-2
HEATER, AIR CONDITIONING AND VENTILATION
GENERAL DESCRIPTION
ZC600369 0000
Interior temperature sensor
ZC6003700000
Ambient temperature sensor
ZC6003710000
A/C pressure sensor
ZC6003720000
Photo sensor
HEATER, AIR CONDITIONING AND VENTILATION
55-3
GENERAL DESCRIPTION
Heater unit
Liquid pipe
Suction pipe
Suction
flexible hose
Discharge
flexible hose
Condenser
A/C compressor
ZC6000210000
Low-pressure side valve
High-pressure
side valve
Receiver
HEATER UNIT
M25501000008USA0000010000
55-4
HEATER, AIR CONDITIONING AND VENTILATION
HEATER UNIT
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.