Mitsubishi Montero (2004+). Manual — part 301
MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI)
13A-691
STEP 3. Measure the power supply voltage at throttle
actuator control motor relay harness side connector B-23X
(1) Disconnect the connector B-23X and measure at the
harness side.
(2) Measure the voltage between terminal No. 3 and ground.
• Voltage should be battery positive voltage.
Q: Is battery positive voltage (approximately 12 volts)
present?
YES : Go to Step 4.
NO : Check harness connector A-03 at intermediate
connector for damage, and repair or replace as
required. Refer to GROUP 00E, Harness Connector
Inspection
. If intermediate connector A-03 is
in good condition, repair it because of open circuit or
short circuit to ground between fusible link (5) and
throttle actuator control motor relay connector B-23X
(terminal No. 3). Then go to Step 14.
STEP 4. Measure the power supply voltage at throttle
actuator control motor relay harness side connector
B-23X.
(1) Disconnect the connector B-23X and measure at the
harness side.
(2) Turn the ignition switch to the "ON" position.
(3) Measure the voltage between terminal No. 4 and ground.
• Voltage should be battery positive voltage.
(4) Turn the ignition switch to the "LOCK"(OFF) position.
Q: Is battery positive voltage (approximately 12 volts)
present?
YES : Go to Step 6.
NO : Go to Step 5.
AK201172
2 1
3
4
B-23X
AB
CONNECTOR: B-23X
HARNESS
CONNECTOR:
COMPONENT SIDE
2 1
3
4
AK201382AC
B-23X HARNESS
CONNECTOR:
COMPONFNT SIDE
AK201172
2 1
3
4
B-23X
AB
CONNECTOR: B-23X
HARNESS
CONNECTOR:
COMPONENT SIDE
2 1
3
4
AK201383
B-23X HARNESS
CONNECTOR:
COMPONFNT SIDE
AC
MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI)
13A-692
STEP 5. Check connector B-22X at MFI relay for damage.
Q: Is the connector in good condition?
YES : Repair harness wire between MFI relay connector
B-22X (terminal No. 1) and throttle actuator control
motor relay connector B-23X (terminal No. 4)
because of open circuit or short circuit to ground.
Then go to Step 14.
NO : Repair or replace it. Refer to GROUP 00E, Harness
Connector Inspection
. Then go to Step 14.
STEP 6. Measure the power supply voltage at PCM harness
side connector D-132.
(1) Disconnect the connector D-132 and measure at the
harness side.
(2) Turn the ignition switch to the "ON" position.
(3) Measure the voltage between terminal No. 15 and ground.
• Voltage should be battery positive voltage.
(4) Turn the ignition switch to the "LOCK"(OFF) position.
Q: Is battery positive voltage (approximately 12 volts)
present?
YES : Go to Step 7.
NO : Repair harness wire between throttle actuator control
motor relay connector B-23X (terminal No. 2) and
PCM connector D-132 (terminal No. 15) because of
open circuit or short circuit to ground. Then go to Step
14.
AK200951
2 1
3
4
B-22X
AB
CONNECTOR: B-22X
HARNESS
CONNECTOR:
COMPONENT SIDE
AK200938
2
3
4
5
6
7
8
9
1
10
14
15
16
17
18
19
20
21
22
23
24
25
26
27
11
12
13
AB
CONNECTOR: D-132
HARNESS CONNECTOR:
COMPONENT SIDE
PCM
D-132(GR)
2
3
4
5
6
7
8
9
1
10
14
15
16
17
18
19
20
21
22
23
24
25
26
27
11
12
13
AK201447
D-132 HARNESS
CONNECTOR:
COMPONENT SIDE
AB
MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI)
13A-693
STEP 7. Measure the power supply voltage at PCM harness
side connector D-136.
(1) Disconnect the connector D-136 and measure at the
harness side.
(2) Turn the ignition switch to the "ON" position.
(3) Measure the voltage between terminal No. 132 and ground.
• Voltage should be battery positive voltage.
(4) Turn the ignition switch to the "LOCK"(OFF) position.
Q: Is battery positive voltage (approximately 12 volts)
present?
YES : Go to Step 10.
NO : Go to Step 8.
AK201170
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
CONNECTOR: D-136
PCM
D-136(GR)
HARNESS CONNECTOR:
COMPONENT SIDE
AB
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
AK201448
AB
D-136 HARNESS
CONNECTOR:
COMPONENT SIDE
MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI)
13A-694
STEP 8. Check for open circuit and short circuit to ground
between throttle actuator control motor relay connector
B-23X (terminal No. 1) and PCM connector D-136 (terminal
No. 132).
Q: Is the harness wire in good condition?
YES : Go to Step 9.
NO : Repair it. Then go to Step 14.
AK201172
2 1
3
4
B-23X
AB
CONNECTOR: B-23X
HARNESS
CONNECTOR:
COMPONENT SIDE
AK201170
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
CONNECTOR: D-136
PCM
D-136(GR)
HARNESS CONNECTOR:
COMPONENT SIDE
AB