Mitsubishi Montero (2004+). Manual — part 1149
WATER PUMP
TSB Revision
ENGINE COOLING
14-15
2. Check that the amount of valve lift is at the standard value
when the water is at the full-opening temperature.
NOTE: Measure the valve height when the thermostat is
fully closed, and use this measurement to compare the
valve height when the thermostat is fully open.
Standard value:
Full-opening temperature: 95
°C (203°F)
Amount of valve lift: 10 mm (0.39 inch) or more
WATER PUMP
REMOVAL AND INSTALLATION
M1141002700528
ACX00401AB
VALVE LIFT
Pre-removal and Post-installation Operation
• Engine Coolant Draining and Refilling (Refer to
• Timing Belt Removal and Installation (Refer to GROUP
11A, Timing Belt
• Camshaft Sprocket Removal and Installation (Refer to
GROUP 11A, Camshaft and Valve stem seal
AC204068
Bolt specifications
Thread diameter × length mm (in)
8 × 25
(0.3 × 1.0)
8 × 22
(0.3 × 0.9)
11
14 ± 1 N·m
120 ± 13 in-lb
12 ± 1 N·m
102 ± 13 in-lb
12 ± 1 N·m
102 ± 13 in-lb
9.0 ± 1.0 N·m
80 ± 9 in-lb
24 ± 3 N·m
18 ± 2 ft-lb
1
5
3
4
2
6
12
13
11
10
7
8
9
N
N
N
N
N
N
AB
14
15
16
17
13 ± 2 N·m
111 ± 22 in-lb
14 ± 1 N·m
120 ± 13 in-lb
WATER PUMP
TSB Revision
ENGINE COOLING
14-16
REMOVAL SERVICE POINT
.
<<A>> RADIATOR UPPER HOSE DISCONNECTION
After making mating marks on the radiator hose and hose
clamp, disconnect the radiator hose.
INSTALLATION SERVICE POINTS
.
>>A<< O-RING INSTALLATION
Fit the O rings into the groove of the water pipe ends, and apply
water to the circumference of the O ring and the pipe bores to
insert the pipe assembly.
.
REMOVAL STEPS
1.
ENGINE COOLANT
TEMPERATURE SENSOR
CONNECTOR
2.
ENGINE COOLANT
TEMPERATURE GAUGE UNIT
CONNECTOR
3.
SPARK PLUG CABLE SUPPORT
<<A>> >>B<<
4.
RADIATOR UPPER HOSE
CONNECTION
5.
WATER HOSE
6.
WATER HOSE
7.
WATER OUTLET FITTING
BRACKET
8.
WATER OUTLET FITTING
>>A<<
9.
O-RING
10. GASKET
11. WATER PUMP ASSEMBLY
12. GASKET
>>A<<
13. O-RING
14. FITTING
15. GASKET
16. THERMOSTAT CASE
17. GASKET
REMOVAL STEPS (Continued)
AC200641AB
MATING MARKS
AC200644 AB
O-RING
WATER PIPE
WATER HOSE AND WATER PIPE
TSB Revision
ENGINE COOLING
14-17
>>B<< RADIATOR UPPER HOSE CONNECTION
1. Insert each hose as far as the projection of the water outlet
fitting.
2. Align the mating marks on the radiator hose and hose
clamp, and then connect the radiator hose.
WATER HOSE AND WATER PIPE
REMOVAL AND INSTALLATION
M1141003300288
AC200642
MATING
MARKS
PROJECTION
WATER OUTLET
FITTING
AB
Pre-removal and Post-installation Operation
• Engine Coolant Draining and Supplying (Refer to
.)
• Intake Manifold Removal and Installation (Refer to
GROUP 15, Intake Manifold
• Thermostat Removal and Installation (Refer to
AC204094
1
2
3
4
5
6
7
8
8
9
10
11
10
12
13
14
15
16
14 ± 1 N·m
120 ± 13 in-lb
14 ± 1 N·m
120 ± 13 in-lb
14 ± 1 N·m
120 ± 13 in-lb
12 ± 1 N·m
102 ± 13 in-lb
9.0 ± 1.0 N·m
80 ± 9 in-lb
19 ± 1 N·m
14 ± 1 ft-lb
AB
N
N
N
N
N
N
REMOVAL STEPS
<<A>> >>D<<
1.
RADIATOR UPPER HOSE
CONNECTION
2.
WATER HOSE
3.
WATER HOSE
4.
WATER OUTLET FITTING AND
THERMOSTAT CASE
REMOVAL STEPS (Continued)
WATER HOSE AND WATER PIPE
TSB Revision
ENGINE COOLING
14-18
REMOVAL SERVICE POINT
.
<<A>> RADIATOR UPPER HOSE DISCONNECTION
After making mating marks on the radiator hose and hose
clamp, disconnect the radiator hose.
INSTALLATION SERVICE POINTS
.
>>A<< GASKET INSTALLATION
Bend over the tabs to secure the gasket to the water passage
assembly.
.
>>B<< WATER HOSE CONNECTION
To reuse the water hose, align the mating marks that were
made during removal, and then install the hose clamp.
.
5.
GASKET
6.
FITTING
7.
GASKET
8.
WATER HOSE
9.
WATER OUTLET PIPE
ASSEMBLY
>>C<<
10. O-RING
11. HEATER HOSE CONNECTION
12. WATER PIPE ASSEMBLY
>>C<<
13. O-RING
>>B<<
14. HEATER HOSE CONNECTION
15. WATER PASSAGE ASSEMBLY
>>A<<
16. GASKET
REMOVAL STEPS (Continued)
AC200641AB
MATING MARKS
ACX01830
GASKET
TAB
WATER PASSAGE ASSEMBLY
AB