Mitsubishi Outlander GS45X. Manual — part 1627
DIAGNOSIS
TSB Revision
CVT
23A-65
DTC P0741: Abnormality in Lock-up Function
.
DIAGNOSTIC FUNCTION
Abnormality is detected by the TCM when the torque
converter slip speed is high during lockup control.
.
DESCRIPTIONS OF MONITOR METHODS
• The status with the high torque converter slip
speed continues for 30 seconds during lockup
control [Primary pulley speed and engine speed
are normal, and lockup differential pressure is 0.2
MPa (29 psi) or more].
.
MONITOR EXECUTION
• Transmission range: D
• Throttle valve opening : 1/8 or more
• Engine speed : 450 r/min or more
• CVT fluid temperature : from 20 to 180°C
(68~356
°F)
.
MONITOR EXECUTION CONDITIONS
(OTHER MONITOR AND SENSOR)
Other Monitor (There is no temporary DTC stored
in memory for the item monitored below)
• P0746: Abnormality in hydraulic control system
function
• P0841: Abnormality in line pressure sensor func-
tion
• P0868: Secondary pressure drop
Sensor (The sensor below is determined to be
normal)
• Not applicable
.
DIAGNOSIS
TSB Revision
CVT
23A-66
LOGIC FLOW CHARTS (Monitor Sequence)
.
DTC SET CONDITIONS
Check Conditions
• Transmission range switch position: D.
• Throttle position sensor voltage: 1.37 volts or
more.
• Engine speed: 450 r/min or more.
• Transmission fluid temperature: 20°C (68°F) or
more.
• Transmission fluid temperature: 180°C (356°F) or
less.
• Voltage of battery: 9 volts or more.
• Voltage of battery: 16 volts or less.
JUDGMENT CRITERIA
• Lock-up pressure: 0.2 MPa (29 psi) or more. (30
seconds)
• Torque converter slip revolution: 40+(vehicle
speed/2) or more. (30 seconds)
.
OBD-II DRIVE CYCLE PATTERN
Transmission range: D (Drive the vehicle for 30 sec-
onds or more while the accelerator opening angle is
20% or more)
.
PROBABLE CAUSES
• Abnormal line pressure
• Malfunction of TCM
AC710013
START
Lockup pressure 0.2 MPa (29 psi)
Yes
No
Yes
No
Good
Malfunction
END
Yes
No
Yes
No
Torque convertor slip revolution
Continuous failure for 30 secs.
40 + (Vehicle speed/2)
All secondary parameters
are in the enable condition.
DIAGNOSIS
TSB Revision
CVT
23A-67
DIAGNOSTIC PROCEDURE
STEP 1. Check other diagnostic trouble codes.
Q: Are other diagnostic trouble codes set?
YES : Carry out the appropriate troubleshooting.
NO : Go to Step 2.
STEP 2. M.U.T.-III data list
• Item 7: Primary speed
• Item 9: Engine revolution
OK: No considerable difference is observed between
the primary pulley speed and the engine speed.
Q: Is the check result normal?
YES : Intermittent malfunction
NO : Go to Step 3.
STEP 3. Line Pressure Check
Carry out "hydraulic test"(Refer to
Q: Is the check result normal?
YES : Go to Step 4.
NO : Repair according to the hydraulic pressure test
diagnosis table.
STEP 4. Symptom recheck after erasing diagnostic trouble
code
Q: Is the check result normal?
YES : Intermittent malfunction
NO : Replace TCM.
DTC P0745: Malfunction of Line Pressure Solenoid Valve
.
SOLENOID VALVE SYSTEM CIRCUIT
Refer to
.
DIAGNOSTIC FUNCTION
TCM determines malfunction by detecting the abnor-
mality in the line pressure solenoid valve.
.
DESCRIPTIONS OF MONITOR METHODS
• Specified amount of current is not flown to the
line pressure solenoid valve because of an open
or short circuit.
.
MONITOR EXECUTION
• Continuous
.
MONITOR EXECUTION CONDITIONS
(OTHER MONITOR AND SENSOR)
Other Monitor (There is no temporary DTC stored
in memory for the item monitored below)
• P0741: Abnormality in lockup function
• P0746: Abnormality in hydraulic control system
function
• P0841: Abnormality in line pressure sensor func-
tion
• P0868: Secondary pressure drop
Sensor (The sensor below is determined to be
normal)
• Not applicable
.
DIAGNOSIS
TSB Revision
CVT
23A-68
LOGIC FLOW CHARTS (Monitor Sequence)
.
DTC SET CONDITIONS
JUDGMENT CRITERIA
• Monitored current [target current: 750 mA or
more]: 400 mA or less. (5 seconds)
• Monitored current: 1.34 A or more. (1 second)
.
OBD-II DRIVE CYCLE PATTERN
Ignition switch : ON (start the engine and keep it for
10 seconds or more)
.
PROBABLE CAUSES
• Malfunction of valve body assembly (Faulty line
pressure solenoid valve)
• Damaged wiring harness and connectors
• Malfunction of TCM
AC609280
START
Yes
Yes
No
Continuous failure for 5 sec
No
No
Yes
Good
Malfunction
END
Yes
Yes
No
No
PU solenoid circuit is ground short
Target current 750 mA
Monitored current 400 mA
Continuous failure for 1 sec
Monitored current 1.34 A
AC