Mitsubishi Outlander GS45X. Manual — part 1064
DOOR
TSB Revision
BODY
42A-59
STEP 13. Check the wiring harness between ETACS-ECU
connector C-311 (terminals No. 6 and 9) and rear door lock
actuator (RH) connector E-13 (terminals No. 6 and 4).
• Check the power supply line for open circuit and short cir-
cuit.
NOTE: Also check intermediate connector D-36 for loose, cor-
roded, or damaged terminals, or terminals pushed back in the
connector. If intermediate connector D-36 is damaged, repair or
replace the damaged component(s) as described in GROUP
00E, Harness Connector Inspection
Q: Is the wiring harness between ETACS-ECU connector
C-311 (terminals No. 6 and 9) and rear door lock
actuator (RH) connector E-13 (terminals No. 6 and 4) in
good condition?
YES : Go to Step 24.
NO : The wiring harness may be damaged or the
connector(s) may have loose, corroded or damaged
terminals, or terminals pushed back in the connector.
Repair the wiring harness as necessary. Verify that all
the doors and the liftgate can be locked and unlocked
normally.
STEP 14. Check rear door lock actuator (LH) connector
E-27 for loose, corroded or damaged terminals, or
terminals pushed back in the connector.
Q: Is rear door lock actuator (LH) connector E-27 in good
condition?
YES : Go to Step 15.
NO : Repair or check the connector. Refer to GROUP 00E,
Harness Connector Inspection
. Verify that all
the doors and the liftgate can be locked and unlocked
normally.
DOOR
TSB Revision
BODY
42A-60
STEP 15. Check the rear door lock actuator (LH).
Remove the rear door lock actuator (LH). The illustration shows
when the door lock actuator is viewed from inside the door.
Refer to
.
Q: Is the rear door lock actuator (LH) normal?
YES : Go to Step 16.
NO : Replace the rear door lock actuator (LH). Verify that
all the doors and the liftgate can be locked and
unlocked normally.
STEP 16. Check ETACS-ECU connector C-311 for loose,
corroded or damaged terminals, or terminals pushed back
in the connector.
Q: Is ETACS-ECU connector C-311 in good condition?
YES : Go to Step 17.
NO : Repair or replace the damaged component(s). Refer
to GROUP 00E, Harness Connector Inspection
. Verify that all the doors and the liftgate can
be locked and unlocked normally.
Lever
position
Battery
connection
Lever
operation
At the
"LOCK"
position
• Connect
terminal No.4 to
the negative
battery terminal.
• Connect
terminal No.6 to
the positive
battery terminal.
The lever moves
from the "LOCK"
position to the
"UNLOCK"
position.
At the
"UNLOCK"
position
• Connect
terminal No.6 to
the negative
battery terminal.
• Connect
terminal No.4 to
the positive
battery terminal.
The lever moves
from the
"UNLOCK"
position to the
"LOCK"
position.
4
2
5
3
6
1
AC702907
A
Lever
UNLOCK
LOCK
View A
AB
DOOR
TSB Revision
BODY
42A-61
STEP 17. Check the wiring harness between ETACS-ECU
connector C-311 (terminals No. 6 and 9) and rear door lock
actuator (LH) connector E-27 (terminals No. 6 and 4).
• Check the power supply line for open circuit and short cir-
cuit.
NOTE: Also check intermediate connector D-21 for loose, cor-
roded, or damaged terminals, or terminals pushed back in the
connector. If intermediate connector D-21 is damaged, repair or
replace the damaged component(s) as described in GROUP
00E, Harness Connector Inspection
Q: Is the wiring harness between ETACS-ECU connector
C-311 (terminals No. 6 and 9) and rear door lock
actuator (LH) connector E-27 (terminals No. 6 and 4) in
good condition?
YES : Go to Step 24.
NO : The wiring harness may be damaged or the
connector(s) may have loose, corroded or damaged
terminals, or terminals pushed back in the connector.
Repair the wiring harness as necessary. Verify that all
the doors and the liftgate can be locked and unlocked
normally.
STEP 18. Check liftgate lock actuator connector F-11 for
loose, corroded or damaged terminals, or terminals
pushed back in the connector.
Q: Is liftgate lock actuator connector F-11 in good
condition?
YES : Go to Step 19.
NO : Repair or check the connector. Refer to GROUP 00E,
Harness Connector Inspection
. Verify that all
the doors and the liftgate can be locked and unlocked
normally.
DOOR
TSB Revision
BODY
42A-62
STEP 19. Check the liftgate lock actuator.
Remove the liftgate lock actuator. The illustration shows when
the liftgate lock actuator is viewed from inside the liftgate. Refer
to GROUP 42A, Liftgate Handle and Latch
.
Q: Is the liftgate lock actuator normal?
YES : Go to Step 20.
NO : Replace the liftgate lock actuator. Verify that all the
doors and the liftgate can be locked and unlocked
normally.
STEP 20. Check the ground circuit to the liftgate lock
actuator. Measure the resistance at liftgate lock actuator
connector F-11.
(1) Disconnect liftgate lock actuator connector F-11 and
measure the resistance on the wiring harness side of the
connector.
(2) Measure the resistance value between terminal 2 and
ground.
• The resistance should be 2 ohms or less.
Q: Is the measured resistance 2 ohms or less?
YES : Go to Step 22.
NO : Go to Step 21.
Lever
position
Battery
connection
Lever operation
At the
"SET"
position
• Connect
terminal 2 to
negative battery
terminal.
• Connect
terminal 1 to
positive battery
terminal.
Lever moves
from "SET" to
"OPEN" position.
AC302760AG
Set
Lever
Open
AC702473
Connector F-11
AF
(harness side)
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.