Mitsubishi Space Star. Manual — part 92
ENGINE COOLING – Radiator <F9Q1>
14-11
REMOVAL SERVICE POINT
A
RADIATOR UPPER HOSE/RADIATOR LOWER
HOSE DISCONNECTION
After making mating marks on the radiator hose and the hose
clamp, disconnect the radiator hose.
INSTALLATION SERVICE POINT
A
RADIATOR LOWER HOSE/RADIATOR UPPER
HOSE CONNECTION
1.
Insert each hose as far as the projection of the water
inlet fitting.
2.
Align the mating marks on the radiator hose and hose
clamp, and then connect the radiator hose.
NOTES
15-1
CONTENTS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Waste Gate Actuator Check
2
. . . . . . . . . . . . . . . . . . .
Turbocharger Waste Gate Solenoid Check
3
. . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
INTAKE MANIFOLD AND EXHAUST MANIFOLD
<F9Q1>
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INTAKE AND EXHAUST –
General/Service Specification/
Special Tool/On-vehicle Service <F9Q1>
15-2
GENERAL
OUTLINE OF CHANGES
The service procedures have been established due to the adoption of the intake manifold made of
resin for the 4G93-GDI engine and the change of the exhaust pipe.
The service procedures have been established due to the adoption of the intake manifold made of
steel pipe for the 4G13-MPI engine and the exhaust manifold incorporated with the catalytic converter.
The service procedures have been established due to the introduction of the F9Q1 diesel engine.
Other service procedures are the same as before.
SERVICE SPECIFICATION
Item
Standard value
Turbocharger waste gate solenoid coil resistance
Ω
(at 25
C)
15.5 – 17.5
SPECIAL TOOL
Tool
Number
Name
Use
MD998770
Oxygen sensor
wrench
Removal/Installation of oxygen sensor
ON-VEHICLE SERVICE <F9Q1>
WASTE GATE ACTUATOR CHECK
1.
Disconnect the vacuum hose from the waste gate actuator
nipple.
2.
Connect a hand vacuum pump to the nipple.
3.
Check the rod for smooth movement as vacuum pressure
is gradually applied.