Mitsubishi Lancer Evolution IX. Manual — part 556
TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION
55-97
STEP 18. Check the wiring harness between
A-06X condenser fan relay (LO) connector
terminal No.3 and C-121 engine-ECU connector
terminal No.31.
NOTE:
Prior to the wiring harness inspection, check interme-
diate connector A-29 <LHD> or C-31 <RHD>, and
repair if necessary.
• Check the condenser fan relay (HI) earth line for
open or short circuit.
Q: Is the check result normal?
YES :
Go to Step 19.
NO :
Repair the wiring harness.
AC311017AC
Connector: A-06X
Relay box side
AC504617AB
Connector: C-121 <LHD>
C-121 (GR)
Harness side
AC504624AT
Connectors: C-31, C-121 <RHD>
C-121
Harness side
C-121 (GR)
C-31
C-31
AC310542
6
2
5
1
8
7
3 4
Connector: A-29 <LHD>
AB
A-29 (B)
TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION
55-98
STEP 19. Check the wiring harness between
A-06X condenser fan relay (LO) connector
terminal No.1 and A-34 condenser fan motor
connector terminal No.2.
• Check the condenser fan motor power supply line
for open circuit.
Q: Is the check result normal?
YES :
The trouble can be an intermittent
malfunction (Refer to GROUP 00, How to
Cope with Intermittent Malfunction
NO :
Repair the wiring harness.
STEP 20. Connector check: A-35 condenser fan
motor connector
Q: Is the check result normal?
YES :
Go to Step 21.
NO :
Repair the connector.
AC311017AC
Connector: A-06X
Relay box side
AC310431
Harness side
Connector: A-34 <LHD>
AG
A-34 (B)
AC310433
Harness side
Connector: A-34 <RHD>
AF
A-34 (B)
AC310431
A-35 (GR)
Connector: A-35 <LHD>
Harness side
AH
AC310433
A-35 (GR)
Connector: A-35 <RHD>
Harness side
AG
TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION
55-99
STEP 21. Resistance measurement at A-35
condenser fan motor connector.
(1) Disconnect the connector, and measure at the
wiring harness side.
(2) Measure the resistance value between terminal 1
and earth.
OK: 2 ohms or less
Q: Is the check result normal?
YES :
Replace the engine-ECU.
NO :
Go to Step 22.
STEP 22. Check the wiring harness between A-35
condenser fan motor connector terminal No.1
and earth.
• Check the condenser fan motor earth line for
open circuit.
Q: Is the check result normal?
YES :
The trouble can be an intermittent
malfunction (Refer to GROUP 00, How to
Cope with Intermittent Malfunction
NO :
Repair the wiring harness.
AC310431
A-35 (GR)
Connector: A-35 <LHD>
Harness side
AH
AC310433
A-35 (GR)
Connector: A-35 <RHD>
Harness side
AG
AC310506
AC310506AO
Connector: A-35
(Harness side)
AC310431
A-35 (GR)
Connector: A-35 <LHD>
Harness side
AH
AC310433
A-35 (GR)
Connector: A-35 <RHD>
Harness side
AG
TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION
55-100
DATA LIST REFERENCE TABLE
M1554005100341
Item No.
Check items
Inspection conditions
Normal condition
11
Interior temperature sensor Turn the ignition switch to
the ON position.
Room temperature is the
same as M.U.T.-II/III
displayed temperature.
13
Outside thermo sensor
Turn the ignition switch to
the ON position.
Outside temperature is the
same as M.U.T.-II/III
displayed temperature.
15
Heater water temperature
sensor
Turn the ignition switch to
the ON position.
Heater core wall surface
temperature is the same as
M.U.T.-II/III displayed
temperature.
21
Air thermo sensor
Turn the ignition switch to
the ON position.
Evaporator outlet temperate
is the same as M.U.T.-II/III
displayed temperature
25
Photo sensor
• Turn the ignition switch to
the ON position.
• Change the volume of
insolation.
The volume of insolation
takes inverse proportion with
the M.U.T.-II/III displayed
voltage.
31
Air mixing damper control
motor and potentiometer
• Turn the ignition switch to
the ON position.
• Door position: MAX HOT
Opening angle: approximately
100%
• Turn the ignition switch to
the ON position.
• Door position: MAX
COOL
Opening angle: approximately
0%
32
Mode selection damper
control motor and
potentiometer
• Turn the ignition switch to
the ON position.
• Damper position: FACE
Opening angle: approximately
0%
• Turn the ignition switch to
the ON position.
• Damper position: FOOT
Opening angle: approximately
60%
• Turn the ignition switch to
the ON position.
• Damper position:
FOOT/DEF
Opening angle: approximately
80%
• Turn the ignition switch to
the ON position.
• Damper position: DEF
Opening angle: approximately
100%
42
A/C pressure sensor
Turn the ignition switch to
the ON position.
A/C refrigerant pressure is the
same as M.U.T.-II/III
displayed pressure.
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.