Infiniti M35/M45 Y50. Manual — part 740
VIAS
EC-1433
[VK45DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
Diagnostic Procedure
NBS005PN
1.
CHECK OVERALL FUNCTION
With CONSULT-II
1.
Start engine and warm it up to normal operating temperature.
2.
Perform “VIAS SOL VALVE” in “ACTIVE TEST” mode with CON-
SULT-II.
3.
Turn VIAS control solenoid valve ON and OFF, and make sure
that power valve actuator (1) rod moves.
Without CONSULT-II
1.
Lift up the vehicle.
2.
Start engine and warm it up to normal operating temperature.
3.
Make sure that power valve actuator (1) rod moves when chang-
ing the gear position to N and D alternately.
OK or NG
OK
>> INSPECTION END
NG (With CONSULT-II)>>GO TO 2.
NG (Without CONSULT-II)>>GO TO 3.
PBIB0844E
PBIB2725E
PBIB2725E
EC-1434
[VK45DE]
VIAS
2.
CHECK VACUUM EXISTENCE
With CONSULT-II
1.
Stop engine and disconnect vacuum hose connected to power valve actuator.
2.
Start engine and let it idle.
3.
Perform “VIAS SOL VALVE” in “ACTIVE TEST” mode with CON-
SULT-II.
4.
Turn VIAS control solenoid valve ON and OFF, and check vac-
uum existence under the following conditions.
OK or NG
OK
>> Repair or replace power valve actuator.
NG
>> GO TO 4.
3.
CHECK VACUUM EXISTENCE
Without CONSULT-II
1.
Stop engine and disconnect vacuum hose connected to power valve actuator.
2.
Disconnect VIAS control solenoid valve (1) harness connector.
–
: Vehicle front
3.
Start engine and let it idle.
4.
Apply 12V of direct current between VIAS control solenoid valve
terminals 1 and 2.
5.
Check vacuum existence under the following conditions.
OK or NG
OK
>> Repair or replace power valve actuator.
NG
>> GO TO 4.
VIAS SOL VALVE
Vacuum
ON
Should exist.
OFF
Should not exist.
PBIB0844E
PBIB2694E
Condition
Vacuum
12V direct current supply
Should exist.
No supply
Should not exist.
PBIB0845E
VIAS
EC-1435
[VK45DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
4.
CHECK VACUUM HOSE
1.
Stop engine.
2.
Check hoses and tubes between intake manifold and power
valve actuator for crack, clogging, improper connection or dis-
connection. Refer to
.
OK or NG
OK
>> GO TO 5.
NG
>> Repair hoses or tubes.
5.
CHECK VACUUM TANK
Refer to
EC-1436, "Component Inspection"
.
OK or NG
OK
>> GO TO 6.
NG
>> Replace vacuum tank.
6.
CHECK VIAS CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
1.
Turn ignition switch OFF.
2.
Disconnect VIAS control solenoid valve (1) harness connector.
–
: Vehicle front
3.
Turn ignition switch ON.
4.
Check voltage between terminal 1 and ground with CONSULT-II
or tester.
OK or NG
OK
>> GO TO 8.
NG
>> GO TO 7.
7.
DETECT MALFUNCTIONING PART
Check the following.
●
Harness connectors E12, F3
●
Harness continuity between IPDM E/R and VIAS control solenoid valve
>> Repair open circuit or short to ground or short to power in harness or connectors.
SEF109L
PBIB2694E
Voltage: Battery voltage
PBIB0173E
EC-1436
[VK45DE]
VIAS
8.
CHECK VIAS CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1.
Turn ignition switch OFF.
2.
Disconnect ECM harness connector.
3.
Check harness continuity between ECM terminal 29 and VIAS control solenoid valve terminal 2.
Refer to Wiring Diagram.
4.
Also check harness for short to ground and short to power.
OK or NG
OK
>> GO TO 9.
NG
>> Repair open circuit or short to ground or short to power in harness or connectors.
9.
CHECK VIAS CONTROL SOLENOID VALVE
Refer to
EC-1436, "Component Inspection"
OK or NG
OK
>> GO TO 10.
NG
>> Replace VIAS control solenoid valve.
10.
CHECK INTERMITTENT INCIDENT
Refer to
EC-857, "TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT"
.
>> INSPECTION END
Component Inspection
NBS005PO
VIAS CONTROL SOLENOID VALVE
With CONSULT-II
1.
Reconnect harness connectors disconnected.
2.
Turn ignition switch ON.
3.
Perform “VIAS SOL VALVE” in “ACTIVE TEST” mode.
4.
Check air passage continuity and operation delay time under the
following conditions.
Operation takes less than 1 second.
Without CONSULT-II
Check air passage continuity and operation delay time under the fol-
lowing conditions.
Operation takes less than 1 second.
Continuity should exist.
Condition
VIAS SOL VALVE
Air passage continuity
between (A) and (B)
Air passage continuity
between (A) and (C)
ON
Yes
No
OFF
No
Yes
PBIB0177E
Condition
Air passage continuity
between (A) and (B)
Air passage continuity
between (A) and (C)
12V direct current supply
between terminals 1 and 2
Yes
No
No supply
No
Yes
SEF313Q
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.