Infiniti M35/M45 Y50. Manual — part 79
ON-VEHICLE SERVICE
AT-239
D
E
F
G
H
I
J
K
L
M
A
B
AT
13. Straighten terminal clip to free revolution sensor harness.
14. Remove bolts A, B and C from control valve with TCM.
15. Remove control valve with TCM from transmission case.
CAUTION:
When removing, be careful with the manual valve notch and
manual plate height. Remove it vertically.
16. Remove A/T fluid temperature sensor 2 with bracket from con-
trol valve with TCM.
17. Remove bracket from A/T fluid temperature sensor 2.
SCIA7525E
Bolt symbol
Length mm (in)
Number of bolts
A
42 (1.65)
5
B
55 (2.17)
6
C
40 (1.57)
1
SCIA5139E
SCIA5142E
SCIA5301E
SCIA5264E
AT-240
ON-VEHICLE SERVICE
18. Remove O-ring from A/T assembly harness connector.
19. Disconnect TCM connectors.
CAUTION:
Be careful not to damage connectors.
20. Remove A/T assembly harness connector from control valve
with TCM using flat-blade screwdriver.
21. Disconnect TCM connector and park/neutral position switch
connector
CAUTION:
Be careful not to damage connectors.
Installation
CAUTION:
After completing installation, check A/T fluid leakage and A/T fluid level. Refer to
SCIA5155E
SCIA5447E
SCIA5448E
SCIA5449E
ON-VEHICLE SERVICE
AT-241
D
E
F
G
H
I
J
K
L
M
A
B
AT
1.
Connect TCM connector and park/neutral position switch con-
nector.
2.
Install A/T assembly harness connector to control valve with
TCM.
3.
Connect TCM connectors.
4.
Install new O-ring in A/T assembly harness connector.
CAUTION:
●
Do not reuse O-ring.
●
Apply ATF to O-ring.
5.
Install A/T fluid temperature sensor 2 to bracket.
SCIA5449E
SCIA5450E
SCIA5447E
SCIA5155E
SCIA5264E
AT-242
ON-VEHICLE SERVICE
6.
Install A/T fluid temperature sensor 2 (with bracket) in control
valve with TCM. Tighten A/T fluid temperature sensor 2 bolt to
the specified torque. Refer to
.
CAUTION:
Adjust bolt hole of bracket to bolt hole of control valve with
TCM.
7.
Install control valve with TCM in transmission case.
CAUTION:
●
Make sure that turbine revolution sensor securely installs
turbine revolution sensor hole.
●
Hang down revolution sensor harness toward outside so
as not to disturb installation of control valve with TCM.
●
Adjust A/T assembly harness connector of control valve
with TCM to terminal hole of transmission case.
●
Assemble it so that manual valve cutout is engaged with
manual plate projection.
8.
Install bolts A, B and C in control valve with TCM.
SCIA5301E
SCIA5034E
SCIA5142E
Bolt symbol
Length mm (in)
Number of bolts
A
42 (1.65)
5
B
55 (2.17)
6
C
40 (1.57)
1
SCIA5139E