Infiniti M35/M45 Y50. Manual — part 600



DTC P0011, P0021 IVT CONTROL

EC-873

[VK45DE]

C

D

E

F

G

H

I

J

K

L

M

A

EC

Wiring Diagram

NBS005BD

BANK 1

TBWT1012E

EC-874

[VK45DE]

DTC P0011, P0021 IVT CONTROL

Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.

CAUTION:

Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.

: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)

TER-

MINAL

NO.

WIRE

COLOR

ITEM

CONDITION

DATA (DC Voltage)

10

W/G

Intake valve timing control
solenoid valve (bank 1)

[Engine is running]

Warm-up condition

Idle speed

BATTERY VOLTAGE
(11 - 14V)

[Engine is running]

Warm-up condition

Engine speed: 2,000rpm

7 - 12V

72

L

Intake valve timing control
position sensor (bank 1)

[Engine is running]

Warm-up condition

Idle speed

0 - 1.0V

[Engine is running]

Engine speed: 2,000rpm

0 - 1.0V

111

SB

ECM relay
(Self shut-off)

[Engine is running]
[Ignition switch: OFF]

For a few seconds after turning ignition
switch OFF

0 - 1.5V

[Ignition switch: OFF]

More than a few seconds after turning igni-
tion switch OFF

BATTERY VOLTAGE
(11 - 14V)

119

120

R
R

Power supply for ECM

[Ignition switch: ON]

BATTERY VOLTAGE
(11 - 14V)

PBIB1790E

PBIB2734E

PBIB2735E

DTC P0011, P0021 IVT CONTROL

EC-875

[VK45DE]

C

D

E

F

G

H

I

J

K

L

M

A

EC

BANK 2

TBWT1013E

EC-876

[VK45DE]

DTC P0011, P0021 IVT CONTROL

Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.

CAUTION:

Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.

: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)

TER-

MINAL

NO.

WIRE

COLOR

ITEM

CONDITION

DATA (DC Voltage)

11

G/O

Intake valve timing control
solenoid valve (bank 2)

[Engine is running]

Warm-up condition

Idle speed

BATTERY VOLTAGE
(11 - 14V)

[Engine is running]

Warm-up condition

Engine speed: 2,000rpm

7 - 12V

53

LG

Intake valve timing control
position sensor (bank 2)

[Engine is running]

Warm-up condition

Idle speed

0 - 1.0V

[Engine is running]

Engine speed: 2,000 rpm

0 - 1.0V

111

SB

ECM relay
(Self shut-off)

[Engine is running]
[Ignition switch: OFF]

For a few seconds after turning ignition
switch OFF

0 - 1.5V

[Ignition switch: OFF]

More than a few seconds after turning igni-
tion switch OFF

BATTERY VOLTAGE
(11 - 14V)

119

120

R
R

Power supply for ECM

[Ignition switch: ON]

BATTERY VOLTAGE
(11 - 14V)

PBIB1790E