Infiniti M45 (Y34). Manual — part 212
REMOTE KEYLESS ENTRY SYSTEM
BL-73
C
D
E
F
G
H
J
K
L
M
A
B
BL
IVMS COMMUNICATION INSPECTION
IVMS contains the IVMS communication diagnosis and wake-up diagnosis.
IVMS Communication Diagnosis
●
IVMS communication diagnosis consists of the communication diagnosis, sleep diagnosis, and inactive
communication diagnosis between BCM and each local unit (LCU), and display the results on the CON-
SULT-II screen.
NOTE:
Sleep is a power saving function when a vehicle is stationary (all BCM related electrical equipment: OFF,
and the timer: OFF).
●
The function also stores the communication malfunction records and inactive communication records, and
displays the data on the CONSULT-II screen (Malfunction record diagnosis)
*: malfunctioning item record
Operation Procedure
1.
Touch “IVMS-COMM CHECK” on “SELECT TEST ITEM”.
2.
Touch “IVMS-COMM DIAGNOSIS” on “SELECT DIAG ITEM” screen.
3.
Touch “START” on “IVMS-COMM DIAGNOSIS” screen to start the diagnosis.
4.
After the diagnosis is completed, the malfunctioning system is displayed.
5.
When the malfunctioning items are displayed, touch “PRINT” to record.
6.
Touch “ERASE”.
7.
Perform the communication inspection again to make sure that any malfunctioning item is displayed.
8.
Check the displayed items.
Wake-Up Diagnosis
The wake-up diagnosis is carried out when BCM detects the wake-up signal from each local unit (LCU). When
the switch shown on the screen is operated as instructed, each local control unit (LCU) outputs the wake-up
signal. If BCM cannot detect a wake-up signal, it is judged malfunctioning. The malfunctioning local control
unit (LCU) is displayed on the screen.
NOTE:
If any unspecified switch is operated, “Switch data not match” is displayed as a malfunctioning system.
Operation Procedure
1.
Touch “IVMS-COMM CHECK” on “SELECT TEST ITEM” screen.
2.
Touch “WAKE-UP DIAGNOSIS” on “SELECT DIAG ITEM” screen.
3.
Touch “START” on “WAKE-UP DIAGNOSIS” screen to start the diagnosis.
4.
Touch “NEXT” to select the local control unit (LCU) to be diagnosed.
5.
Check that any malfunction is displayed. If necessary, touch “PRINT” to record.
6.
Preform the inspection to the malfunctioning item.
Malfunction description
CONSULT-II
display item
Description
Communication mal-
function
COMM DATA
Communicating with each LCU is judged sound when the communication is normally
completed and the transmitted data and received data are identically the same. In
other cases, it is judged malfunctioning. If the communication is inactive, no diagno-
sis result is displayed.
Inactive communication
NO RESPONSE
Communicating with each LCU is judged sound when at least one time communica-
tion is normally completed within three trials. In other cases, it is judged malfunction-
ing.
Sleep malfunction
SLEEP
Make sure that each LCU enters sleep mode.
Communication mal-
function*
PAST COMM
DATA
The records when communication signal malfunctions were continuously detected
while the communication was normal are displayed. Or the records when a malfunc-
tion is detected during the past sleep mode are displayed.
Inactive communication*
PAST NO
RESPONSE
The records when inactive communications were continuously detected while the
communication was normal are displayed.
BL-74
REMOTE KEYLESS ENTRY SYSTEM
Malfunction Code Table
NOTE:
●
For a specific local control unit (LCU), either “PAST COMM DATA” or “PAST NO RESPONSE” may be displayed instead of the
above results. This is caused by the data record, so erase the records.
(The display only shows the incident records, they are not malfunctions caused during the diagnosis. One possible cause is that an
reproducible incident occurred.)
●
Follow the steps below to erase the memory
Perform either disconnect BCM battery power supply or erase memory with CONSULT-II.
●
With the battery connected, if the local control unit (LCU) connector is disconnected and left for approximately 1 minute, the BCM
stores “NO RESPONSE” record.
Malfunctioning item
Display unit
CONSULT-II IVMS communication diag-
nosis content
Self-diagnosis
trouble code
No.
Malfunctioning system and
reference
COMM DATA
One LCU is dis-
played.
POWER WINDOW C/U-DR
“COMM DATA”
24
Replace the displayed
LCU.
DOOR MIRROR C/U-RH
“COMM DATA”
27
DOOR MIRROR C/U-LH
“COMM DATA”
37
POWER SEAT C/U-DR
“COMM DATA”
47
Multiple LCUs
are displayed.
BCM
“COMM FAIL1”, “COMM FAIL2”
Displays in
order of 24
→
27
→
37
→
47
→
and cycles
from 24.
Communication system A:
Refer to
.
NO
RESPONSE
One LCU is dis-
played.
POWER WINDOW C/U-DR
“NO RESPONSE”
25
Communication system B:
Refer to
.
DOOR MIRROR C/U-RH
“NO RESPONSE”
28
DOOR MIRROR C/U-LH
“NO RESPONSE”
38
POWER SEAT C/U-DR
“NO RESPONSE”
48
Multiple LCUs
are displayed.
BCM/HARNESS
Displays in
order of
25
→
28
→
38
→
4
8 and cycles
from 25.
Communication system C:
Refer to
SLEEP malfunction
One LCU is dis-
played.
POWER WINDOW C/U-DR
“SLEEP”
No self-diagno-
sis function
Replace the displayed
LCU.
DOOR MIRROR C/U-RH
“SLEEP”
DOOR MIRROR C/U-LH
“SLEEP”
POWER SEAT C/U-DR
“SLEEP”
Multiple LCUs
are displayed.
All the above control units are displayed.
No self-diagno-
sis function
Communication system A:
Refer to
.
REMOTE KEYLESS ENTRY SYSTEM
BL-75
C
D
E
F
G
H
J
K
L
M
A
B
BL
DATA MONITOR
Remote Keyless Entry Item
Trunk Lid Opener Item
ACTIVE TEST
Remote Keyless Entry Test Item
Trunk Lid Opener Test Item
WORK SUPPORT
Work Support Item
Monitored item
Description
IGN KEY SW
Indicates [ON/OFF] condition of ignition key switch.
IGN ACC SW
Indicates [ON/OFF] condition of ignition switch in ACC position.
DOOR SW-DR
Indicates [ON/OFF] condition of front door switch LH.
DOOR SW-AS
Indicates [ON/OFF] condition of front door switch RH.
DOOR SW-RR
Indicates [ON/OFF] condition of rear door switch RH.
DOOR SW-RL
Indicates [ON/OFF] condition of rear door switch LH.
LOCK SIG-DR
Indicates [ON/OFF] condition of driver door unlock signal from door unlock sensor.
LOCK SIG-AS
Indicates [ON/OFF] condition of passenger door unlock signal from door unlock sensor.
LOCK SIG-RR/RH
Indicates [ON/OFF] condition of rear RH door unlock signal from door unlock sensor.
LOCK SIG-RR/LH
Indicates [ON/OFF] condition of rear LH door unlock signal from door unlock sensor.
LOCK BUTTON
Indicates [ON/OFF] condition of lock signal from electronic key.
UNLOCK BUTTON
Indicates [ON/OFF] condition of unlock signal from electronic key.
PANIC BTN
Indicates [ON/OFF] condition of panic signal from electronic key.
TRUNK BTN-CON
Indicates [ON/OFF] condition of trunk open signal from electronic key.
Monitored item
Description
TRUNK OPNR SW
Indicates [ON/OFF] condition of trunk open signal from trunk open switch.
TEST ITEM
DESCRIPTION
TRUNK OPEN S/V
This test is able to check trunk lid opener actuator operation.
The trunk is unlocked when “ON” on CONSULT-II screen is touched.
HAZARD
This test is able to check hazard reminder operation.
The hazard lamp turns on when “ON” on CONSULT-II screen is touched.
HORN
This test is able to check panic alarm and horn reminder operations.
The horn turns on when “ON” on CONSULT-II screen is touched.
TEST ITEM
DESCRIPTION
TRUNK OPEN S/V
This test is able to check trunk lid opener actuator operation.
The trunk is unlocked when “ON” on CONSULT-II screen is touched.
WORK ITEM
DESCRIPTION
KYLS OP CONF SET
Hazard and horn reminder mode can be changed in this mode. (NORMAL or MODE1)
KYLS ID P/W SET
Keyless power window down (open) operation mode can be changed in this mode. (ON or OFF)
REMO CONT ID CONFIR
It can be checked whether electronic key ID code is registered or not in this mode.
REMO CONT ID REG
electronic key ID code can be registered in this mode.
REMO CONT ID ERASUR
electronic key ID code can be erased in this mode.
BL-76
REMOTE KEYLESS ENTRY SYSTEM
Hazard and Horn Reminder Mode
*: These modes are not supported.
On Board Diagnosis
AIS001DX
ON BOARD DIAGNOSTIC RESULTS INDICATOR LAMP
●
Map lamps and step lamps (all seats) act as the indicators for the on board diagnosis.
DIAGNOSIS ITEM
COMMUNICATION DIAGNOSIS
Check the communication between BCM and local control unit (LCU).
How to Perform Communication Diagnosis
Description
In this mode, a malfunction code is indicated by the number of flashes from the map lamps and step lamps as
shown below:
NORMAL
MODE1
MODE2*
MODE3*
MODE4*
MODE5*
Electronic key operation
Lock
Unlock
Lock
Unlock
—
—
—
—
Hazard warning lamp flash
Twice
Once
Twice
–
Horn sound
Once
–
–
–
Diagnosis item.
Content
IVMS communication diagnosis
Diagnosing any abnormality or inability of communication between BCM and LCU
(DATA LINE A-3).
Switch monitor
Monitoring conditions of switches connected to BCM, LCU and Door control unit.
PIIA2871E
SIIA0410E
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.