TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT
PFP:00006
Description
ABS002E2
Intermittent incidents may occur. In many cases, the malfunction resolves itself (the part or circuit function
returns to normal without intervention). It is important to realize that the symptoms described in the customer's
complaint often do not recur on (1st trip) DTC visits. Realize also that the most frequent cause of I/I occur-
rences is poor electrical connections. Because of this, the conditions under which the incident occurred may
not be clear. Therefore, circuit checks made as part of the standard diagnostic procedure may not indicate the
specific malfunctioning area.
Common Intermittent Incidents Report Situations
Diagnostic Procedure
ABS002E3
1.
INSPECTION START
Erase (1st trip) DTCs. Refer to
EC-62, "HOW TO ERASE EMISSION-RELATED DIAGNOSTIC INFORMA-
.
>> GO TO 2.
2.
CHECK GROUND TERMINALS
Check ground terminals for corroding or loose connection.
Refer to
.
OK or NG
OK
>> GO TO 3.
NG
>> Repair or replace.
3.
SEARCH FOR ELECTRICAL INCIDENT
Perform
GI-26, "How to Perform Efficient Diagnosis for an Electrical Incident"
, “INCIDENT SIMULATION
TESTS”.
OK or NG
OK
>> GO TO 4.
NG
>> Repair or replace.
4.
CHECK CONNECTOR TERMINALS
Refer to
GI-23, "How to Check Terminal"
, “HOW TO PROBE CONNECTORS”, “How to Check Enlarged Con-
tact Spring of Terminal”.
OK or NG
OK
>> INSPECTION END
NG
>> Repair or replace connector.
STEP in Work Flow
Situation
II
The CONSULT-II is used. The SELF-DIAG RESULTS screen shows time data other than[0] or [1t].
III
The symptom described by the customer does not recur.
IV
(1st trip) DTC does not appear during the DTC Confirmation Procedure.
VI
The Diagnostic Procedure for PXXXX does not indicate the malfunctioning area.