Infiniti M45 (Y34). Manual — part 217
REMOTE KEYLESS ENTRY SYSTEM
BL-93
C
D
E
F
G
H
J
K
L
M
A
B
BL
Check Hazard Reminder Operation
AIS001E5
1.
CHECK BCM OUTPUT SIGNAL
1.
Remove electronic key from ignition key cylinder.
2.
Disconnect flasher unit connector.
3.
Check voltage between flasher unit connector M91 terminal 6 (W/L) and ground.
OK or NG
OK
>> Check flasher unit. Refer to
LT-89, "TURN SIGNAL AND HAZARD WARNING LAMPS"
.
NG
>> GO TO 2.
2.
CHECK COMBINATION FLASHER UNIT CIRCUIT
1.
Disconnect BCM and combination flasher unit connector.
2.
Check continuity between BCM connector M4 terminal 7 (W/
L) and combination flasher unit connector M91 terminal 6 (W/L).
3.
Check continuity between BCM connector M4 terminal 7 (W/L)
and ground.
OK or NG
OK
>> Replace BCM.
NG
>> Repair or replace harness.
Terminal
(Wire color)
Condition
Voltage
6 (W/L) – Ground
LOCK switch ON
with electronic key
UNLOCK switch ON
with electronic key*
*: In the state that haz-
ard reminder oper-
ates.
PIIA2832E
PIIA2487J
PIIA2486J
7 (W/L) – 6 (W/L)
: Continuity should exist.
7 (W/L) – Ground
: Continuity should not exist.
PIIA2831E
BL-94
REMOTE KEYLESS ENTRY SYSTEM
Check Remote Keyless Entry Receiver
AIS001E6
1.
CHECK REMOTE KEYLESS ENTRY RECEIVER POWER SUPPLY CIRCUIT
1.
Remove electronic key from ignition key cylinder.
2.
Disconnect remote keyless entry receiver connector.
3.
Check the voltage between remote keyless entry receiver connector B26 terminal 4 (L) and ground.
OK or NG
OK
>> GO TO 2.
NG
>> GO TO 5.
2.
CHECK REMOTE KEYLESS ENTRY RECEIVER OUTPUT SIGNAL
1.
Connect remote keyless entry receiver connector.
2.
Check the voltage between remote keyless entry receiver connector B26 terminal 2 (BR/W) and ground.
OK or NG
OK
>> GO TO 3.
NG
>> GO TO 4.
Terminal
(Wire color)
Condition
Voltage
4 (L) – Ground
Stand
−
by
PIIA2835E
OCC3881D
Terminal
(Wire color)
Condition
Voltage
2 (BR/W) – Ground
Stand
−
by
Press any of the
electronic key
switches
PIIA2836E
OCC3879D
OCC3880D
REMOTE KEYLESS ENTRY SYSTEM
BL-95
C
D
E
F
G
H
J
K
L
M
A
B
BL
3.
CHECK REMOTE KEYLESS ENTRY RECEIVER HARNESS
1.
Disconnect BCM and remote keyless entry receiver connector.
2.
Check continuity between BCM connector M4 terminal 44 (Y) and remote keyless entry receiver connec-
tor B26 terminal 1 (Y).
3.
Check continuity between BCM connector M4 terminal 44 (Y)
and ground.
OK or NG
OK
>> Remote keyless entry receiver circuit is OK.
NG
>> Repair or replace harness.
4.
CHECK REMOTE KEYLESS ENTRY RECEIVER HARNESS
1.
Disconnect BCM and remote keyless entry receiver connector.
2.
Check continuity between BCM connector M4 terminal 27 (BR/W) and remote keyless entry receiver con-
nector B26 terminal 2 (BR/W).
3.
Check continuity between BCM connector M4 terminal 27 (BR/
W) and ground.
OK or NG
OK
>> Replace remote keyless entry receiver.
NG
>> Repair or replace harness.
5.
CHECK REMOTE KEYLESS ENTRY RECEIVER HARNESS
1.
Disconnect BCM and remote keyless entry receiver connector.
2.
Check continuity between BCM connector M4 terminal 28 (L) and remote keyless entry receiver connec-
tor B26 terminal 4 (L).
3.
Check continuity between BCM connector M4 terminal 28 (L)
and ground.
OK or NG
OK
>> Replace BCM.
NG
>> Repair or replace harness.
44 (Y) – 1 (Y)
: Continuity should exist.
44 (Y) – Ground
: Continuity should not exist.
PIIA3081E
27 (BR/W) – 2 (BR/W)
: Continuity should exist.
27 (BR/W) – Ground
: Continuity should not exist.
PIIA3082E
28 (L) – 4 (L)
: Continuity should exist.
28 (L) – Ground
: Continuity should not exist.
PIIA3083E
BL-96
REMOTE KEYLESS ENTRY SYSTEM
Check Door Lock and Unlock Switch
AIS002J5
1.
CHECK DOOR LOCK AND UNLOCK SWITCH
With CONSULT-II
See “DOOR LK SW-LK and UN” in DATA MONITOR mode with CONSULT-II.
●
When door lock and unlock switch is turned to lock:
●
When lock and unlock switch is turned to unlock:
Without CONSULT-II
Check door lock and unlock switch operation in “SWITCH MONITOR” mode. Refer to
.
OK or NG
OK
>> Door lock and unlock switch is OK.
NG
>> Replace door lock and unlock switch.
Check Hazard Function
AIS002BT
1.
CHECK HAZARD FUNCTION
Does hazard flash with hazard switch?
YES or NO
Yes
>> Hazard function circuit is OK.
No
>> Check hazard circuit. Refer to
LT-89, "TURN SIGNAL AND HAZARD WARNING LAMPS"
Check Headlamp Function
AIS001PZ
1.
CHECK HEADLAMP FUNCTION
Does headlamp come on when turning lighting switch “ON”?
YES or NO
Yes
>> Headlamp function circuit is OK.
No
>> Check headlamp system. Refer to
CANADA) - DAYTIME LIGHT SYSTEM -"
.
Check Power Window Function
AIS002EQ
1.
CHECK POWER WINDOW FUNCTION
Does power window operate with power window switch?
YES or NO
Yes
>> Power window function circuit is OK.
No
>> Check power window system. Refer to
DOOK LK SW-LK
: OFF
→
ON
DOOK LK SW-UN
: OFF
→
ON
SEL561W
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.