Infiniti QX4 (R50). Manual — part 233
6
CLEAN EVAP PURGE LINE
Clean EVAP purge line (pipe and rubber tube) using air blower.
©
GO TO 7.
7
CHECK EVAP CANISTER VENT CONTROL VALVE, O-RING AND CIRCUIT
Refer to “DTC Confirmation Procedure”, EC-375.
OK or NG
OK
©
GO TO 8.
NG
©
Repair or replace EVAP canister vent control valve and O-ring or harness/connector.
8
INSTALL THE PRESSURE PUMP
To locate the EVAP leak, install EVAP service port adapter and pressure pump to EVAP service port securely.
SEF983Y
SEF916U
NOTE:
Improper installation of the EVAP service port adapter to the EVAP service port may cause leaking.
Models with CONSULT-II
©
GO TO 9.
Models without CON-
SULT-II
©
GO TO 10.
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0455 EVAP CONTROL SYSTEM (GROSS LEAK)
Diagnostic Procedure (Cont’d)
EC-399
9
CHECK FOR EVAP LEAK
With CONSULT-II
1. Turn ignition switch “ON”.
2. Select “EVAP SYSTEM CLOSE” of “WORK SUPPORT” mode with CONSULT-II.
3. Touch “START” and apply pressure into the EVAP line until the pressure indicator reaches the middle of the bar graph.
NOTE:
I
Never use compressed air or a high pressure pump.
I
Do not exceed 4.12 kPa (0.042 kg/cm
2
, 0.6 psi) of pressure in the system.
PEF917U
4. Using EVAP leak detector, locate the EVAP leak. For the leak detector, refer to the instruction manual for more details.
Refer to “EVAPORATIVE EMISSION LINE DRAWING”, EC-36.
SEF200U
OK or NG
OK
©
GO TO 11.
NG
©
Repair or replace.
DTC P0455 EVAP CONTROL SYSTEM (GROSS LEAK)
Diagnostic Procedure (Cont’d)
EC-400
10
CHECK FOR EVAP LEAK
Without CONSULT-II
1. Turn ignition switch “OFF”.
2. Apply 12 volts DC to EVAP canister vent control valve. The valve will close. (Continue to apply 12 volts until the end of
test.)
SEF598U
3. Apply 12 volts DC to vacuum cut valve bypass valve. The valve will open. (Continue to apply 12V until the end of test.)
SEF599U
4. Pressurize the EVAP line using pressure pump with 1.3 to 2.7 kPa (10 to 20 mmHg, 0.39 to 0.79 inHg), then remove
pump and EVAP service port adapter.
NOTE:
I
Never use compressed air or a high pressure pump.
I
Do not exceed 4.12 kPa (0.042 kg/cm
2
, 0.6 psi) of pressure in the system.
5. Using EVAP leak detector, locate the EVAP leak. For the leak detector, refer to the instruction manual for more details.
Refer to “EVAPORATIVE EMISSION LINE DRAWING”, EC-36.
SEF200U
OK or NG
OK
©
GO TO 12.
NG
©
Repair or replace.
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0455 EVAP CONTROL SYSTEM (GROSS LEAK)
Diagnostic Procedure (Cont’d)
EC-401
11
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
With CONSULT-II
1. Disconnect vacuum hose to EVAP canister purge volume control solenoid valve at EVAP service port.
2. Start engine.
3. Perform “PURG VOL CONT/V” in “ACTIVE TEST” mode.
4. Touch “Qu” on CONSULT-II screen to increase “PURG VOL CONT/V” opening to 100.0%.
5. Check vacuum hose for vacuum when revving engine up to 2,000 rpm.
SEF984Y
OK or NG
OK
©
GO TO 14.
NG
©
GO TO 13.
12
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
Without CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Stop engine.
3. Disconnect vacuum hose to EVAP canister purge volume control solenoid valve at EVAP service port.
4. Start engine and let it idle for at least 80 seconds.
5. Check vacuum hose for vacuum when revving engine up to 2,000 rpm.
Vacuum should exist.
OK or NG
OK
©
GO TO 15.
NG
©
GO TO 13.
13
CHECK VACUUM HOSE
Check vacuum hoses for clogging or disconnection. Refer to “Vacuum Hose Drawing”, EC-26.
OK or NG
OK (With CONSULT-II)
©
GO TO 14.
OK (Without CONSULT-
II)
©
GO TO 15.
NG
©
Repair or reconnect the hose.
DTC P0455 EVAP CONTROL SYSTEM (GROSS LEAK)
Diagnostic Procedure (Cont’d)
EC-402