Infiniti QX4 (R50). Manual — part 367
HAZARD REMINDER CHECK
=NBEL0115S08
1
CHECK HAZARD INDICATOR
Check if hazard indicator flashes with hazard switch.
Does hazard indicator operate?
Yes
©
GO TO 2.
No
©
Check “hazard indicator” circuit.
2
CHECK HAZARD REMINDER OPERATION
1. Disconnect smart entrance control unit connector.
2. Apply ground to control unit terminal 7.
SEL325X
Refer to wiring diagram in EL-276.
OK or NG
OK
©
Replace smart entrance control unit.
NG
©
GO TO 3.
3
CHECK MULTI-REMOTE CONTROL RELAY
Check multi-remote control relay.
OK or NG
OK
©
GO TO 4.
NG
©
Replace.
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
IDX
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont’d)
EL-285
4
CHECK POWER SUPPLY FOR MULTI-REMOTE CONTROL RELAY
1. Disconnect multi-remote control relay connector.
2. Check voltage between terminal 1 and ground.
SEL326X
OK or NG
OK
©
GO TO 5.
NG
©
Check the following.
I
15A fuse [No. 20, located in fuse block (J/B)]
I
Harness for open or short between multi-remote control relay and fuse
5
CHECK MULTI-REMOTE CONTROL RELAY CIRCUIT
1. Disconnect multi-remote control relay connector.
2. Check voltage between terminals 3 and 5.
3. Check voltage between terminals 6 and 7.
SEL327X
OK or NG
OK
©
Check harness for open or short between smart entrance control unit and multi-remote
control relay.
NG
©
Check the following.
I
Harness for open or short between multi-remote control relay and fuse
I
Harness for open or short between multi-remote control relay and turn signal lamps
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont’d)
EL-286
HORN REMINDER CHECK
=NBEL0115S11
1
CHECK HORN
Check if horn sounds with horn switch.
Does horn operate?
Yes
©
GO TO 2.
No
©
Check horn circuit.
2
CHECK HORN REMINDER OPERATION
1. Disconnect smart entrance control unit connector.
2. Apply ground to smart entrance control unit terminal 19.
SEL328X
Refer to wiring diagram in EL-276.
OK or NG
OK
©
Replace smart entrance control unit.
NG
©
Check harness for open or short between smart entrance control unit and horn relay.
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
IDX
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont’d)
EL-287
INTERIOR ROOM LAMP OPERATION CHECK
=NBEL0115S09
1
CHECK INTERIOR ROOM LAMP
Check if the interior room lamp switch is in the “ON” position and the lamp illuminates.
Does interior room lamp illuminate?
Yes
©
GO TO 2.
No
©
Check the following.
I
Harness for open or short between smart entrance control unit and interior room lamp
I
Interior room lamp
2
CHECK INTERIOR ROOM LAMP CIRCUIT
When interior room lamp switch is “DOOR” position, check voltage across smart entrance control unit terminal 8 and
ground.
SEL329X
Refer to wiring diagram in EL-274.
OK or NG
OK
©
GO TO 3.
NG
©
Repair harness between smart entrance control unit and interior room lamp.
3
CHECK CONTROL UNIT OUTPUT
Push unlock button of remote controller with key removed and all doors closed, and check voltage across smart entrance
control unit terminal 8 and ground.
SEL330X
OK or NG
OK
©
Check system again.
NG
©
Replace smart entrance control unit.
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont’d)
EL-288