Infiniti QX4 (R50). Manual — part 293
SEF029Z
Description
NBEC0636
The refrigerant pressure sensor is installed at the liquid tank of the
air conditioner system. The sensor uses an electrostatic volume
pressure transducer to convert refrigerant pressure to voltage. The
voltage signal is sent to ECM, and ECM controls cooling fan sys-
tem.
SEF099XA
ECM Terminals and Reference Value
NBEC0689
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM’s transistor. Use a ground other than ECM terminals, such as the ground.
TERMI-
NAL
NO.
WIRE
COLOR
ITEM
CONDITION
DATA (DC Voltage)
58
B/P
Sensors’ ground
[Engine is running]
I
Warm-up condition
I
Idle speed
Approximately 0V
81
W/PU
Refrigerant pressure
sensor
[Engine is running]
I
Warm-up condition
I
Both A/C switch and blower switch are “ON”.
(Compressor operates.)
1.0 - 4.0V
111
P/B
Sensors’ power supply
[Ignition switch “ON”]
Approximately 5V
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
REFRIGERANT PRESSURE SENSOR
Description
EC-639
Wiring Diagram
NBEC0637
MEC982C
REFRIGERANT PRESSURE SENSOR
Wiring Diagram
EC-640
Diagnostic Procedure
NBEC0638
1
CHECK REFRIGERANT PRESSURE SENSOR OVERALL FUNCTION
1. Start engine and warm it up to normal operating temperature.
2. Turn A/C switch and blower switch “ON”.
3. Check voltage between ECM terminal 81 and ground with CONSULT-II or tester.
SEF617XA
OK or NG
OK
©
INSPECTION END
NG
©
GO TO 2.
2
CHECK REFRIGERANT PRESSURE SENSOR POWER SUPPLY CIRCUIT
1. Turn A/C switch and blower switch “OFF”.
2. Stop engine.
3. Disconnect refrigerant pressure sensor harness connector.
SEF029Z
4. Turn ignition switch “ON”.
5. Check voltage between refrigerant pressure sensor terminal 1 and ground with CONSULT-II or tester.
SEF030Z
OK or NG
OK
©
GO TO 4.
NG
©
GO TO 3.
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
REFRIGERANT PRESSURE SENSOR
Diagnostic Procedure
EC-641
3
DETECT MALFUNCTIONING PART
Check the following.
I
Harness connectors E1, M1
I
Harness for open or short between ECM and refrigerant pressure sensor
©
Repair harness or connectors.
4
CHECK REFRIGERANT PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch “OFF”.
2. Check harness continuity between refrigerant pressure sensor terminal 1 and engine ground. Refer to Wiring Diagram.
Continuity should exist.
3. Also check harness for short to power.
OK or NG
OK
©
GO TO 6.
NG
©
GO TO 5.
5
DETECT MALFUNCTIONING PART
Check the following.
I
Harness connectors E1, M1 and M33, F22
I
Harness connectors F23, M32
I
Harness for open between ECM and refrigerant pressure sensor
I
Harness for open between TCM (Transmission control module) and refrigerant pressure sensor
©
Repair open circuit or short to power in harness or connectors.
6
CHECK REFRIGERANT PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Disconnect ECM harness connector.
2. Check harness continuity between ECM terminal 81 and refrigerant pressure sensor terminal 2. Refer to Wiring Dia-
gram.
Continuity should exist.
3. Also check harness for short to ground and short to power.
OK or NG
OK
©
GO TO 8.
NG
©
GO TO 7.
7
DETECT MALFUNCTIONING PART
Check the following.
I
Harness connectors E1, M1 and M94, F27
I
Harness for open or short between ECM and refrigerant pressure sensor
©
Repair open circuit or short to ground or short to power in harness or connectors.
8
CHECK REFRIGERANT PRESSURE SENSOR
Refer to HA-14, “Refrigerant pressure sensor”.
OK or NG
OK
©
GO TO 9.
NG
©
Replace refrigerant pressure sensor.
9
CHECK INTERMITTENT INCIDENT
Refer to “TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT”, EC-140.
©
INSPECTION END
REFRIGERANT PRESSURE SENSOR
Diagnostic Procedure (Cont’d)
EC-642
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.