Infiniti Q45. Manual — part 414
DTC P0138, P0158 HO2S2
EC-295
C
D
E
F
G
H
I
J
K
L
M
A
EC
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic Procedure
NBS001UU
PROCEDURE FOR MALFUNCTION A
1.
CHECK GROUND CONNECTIONS
1.
Turn ignition switch OFF.
2.
Loosen and retighten three ground screws on the body.
Refer to
OK or NG
OK
>> GO TO 2.
NG
>> Repair or replace ground connections.
TER-
MINAL
NO.
WIRE
COLOR
ITEM
CONDITION
DATA (DC Voltage)
25
G
Heated oxygen sensor 2
heater (bank 2)
[Engine is running]
●
Engine speed: Below 3,600 rpm after the
following conditions are met
–
Engine: After warming up
–
Keeping the engine speed between 3,500
and 4,000 rpm for 1 minute and at idle for 1
minute under no load
0 - 1.0V
[Ignition switch: ON]
●
Engine stopped
[Engine is running]
●
Engine speed: Above 3,600 rpm
BATTERY VOLTAGE
(11 - 14V)
74
B
Heated oxygen sensor 2
(bank 2)
[Engine is running]
●
Revving engine from idle to 3,000 rpm
quickly after the following conditions are met
–
Engine: After warming up
–
After keeping the engine speed between
3,500 and 4,000 rpm for 1 minute and at idle
for 1 minute under no load
0 - Approximately 1.0V
78
OR
Sensor ground
(Heated oxygen sensor 2)
[Engine is running]
●
Warm-up condition
●
Idle speed
Approximately 0V
PBIB2417E
EC-296
DTC P0138, P0158 HO2S2
2.
CHECK HO2S2 GROUND CIRCUIT FOR OPEN AND SHORT
1.
Disconnect heated oxygen sensor 2 harness connector.
2.
Disconnect ECM harness connector.
3.
Check harness continuity between HO2S2 terminal 4 and ECM terminal 78.
Refer to Wiring Diagram.
4.
Also check harness for short to ground or short to power.
OK or NG
OK
>> GO TO 4.
NG
>> GO TO 3.
3.
DETECT MALFUNCTIONING PART
Check the following.
●
Harness connectors E315, F5
●
Harness for open or short between heated oxygen sensor 2 and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
Continuity should exist.
PBIB0018E
DTC P0138, P0158 HO2S2
EC-297
C
D
E
F
G
H
I
J
K
L
M
A
EC
4.
CHECK HO2S2 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1.
Check harness continuity between ECM terminal and HO2S2 terminal as follows.
Refer to Wiring Diagram.
2.
Check harness continuity between the following terminals and ground.
Refer to Wiring Diagram.
3.
Also check harness for short to ground and short to power.
OK or NG
OK
>> GO TO 6.
NG
>> GO TO 5.
5.
DETECT MALFUNCTIONING PART
Check the following.
●
Harness connectors E315, F5
●
Harness for open or short between heated oxygen sensor 2 and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
6.
CHECK HO2S2 CONNECTOR FOR WATER
1.
Turn ignition switch OFF.
2.
Disconnect heated oxygen sensor 2 harness connector.
3.
Check connectors for water.
OK or NG
OK
>> GO TO 7.
NG
>> Repair or replace harness or connectors.
7.
CHECK HEATED OXYGEN SENSOR 2
Refer to
EC-302, "Component Inspection"
OK or NG
OK
>> GO TO 8.
NG
>> Replace malfunctioning heated oxygen sensor 2.
DTC
Terminals
Bank
ECM
Sensor
P0138
55
1
1
P0158
74
1
2
Continuity should exist.
DTC
Terminals
Bank
ECM
Sensor
P0138
55
1
1
P0158
74
1
2
Continuity should not exist.
Water should not exist.
EC-298
DTC P0138, P0158 HO2S2
8.
CHECK INTERMITTENT INCIDENT
Refer to
EC-145, "TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT"
.
>> INSPECTION END
PROCEDURE FOR MALFUNCTION A
1.
CHECK GROUND CONNECTIONS
1.
Turn ignition switch OFF.
2.
Loosen and retighten three ground screws on the body.
Refer to
OK or NG
OK
>> GO TO 2.
NG
>> Repair or replace ground connections.
PBIB2417E
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.