Infiniti Q45. Manual — part 376
TROUBLE DIAGNOSIS - SPECIFICATION VALUE
EC-143
C
D
E
F
G
H
I
J
K
L
M
A
EC
25.
CHECK INTAKE SYSTEM
Check for the cause of uneven air flow through mass air flow sensor. Refer to the following.
●
Crushed air ducts
●
Malfunctioning seal of air cleaner element
●
Uneven dirt of air cleaner element
●
Improper specification of intake air system
OK or NG
OK
>> GO TO 27.
NG
>> Repair or replace malfunctioning part, and then GO TO 26.
26.
CHECK “B/FUEL SCHDL”
Select “B/FUEL SCHDL” in “DATA MONITOR (SPEC)” mode, and make sure that the indication is within the
SP value.
OK or NG
OK
>> INSPECTION END
NG (Less than the SP value)>>GO TO 27.
27.
CHECK “MAS A/F SE-B1”
Select “MAS A/F SE-B1” in “DATA MONITOR (SPEC)” mode, and
make sure that the indication is within the SP value.
OK or NG
OK
>> GO TO 28.
NG (Less than the SP value)>>Replace mass air flow sensor, and
then GO TO 30.
28.
CHECK INTAKE SYSTEM
Check for the cause of air leak after the mass air flow sensor. Refer to the following.
●
Disconnection, looseness, and cracks in air duct
●
Looseness of oil filler cap
●
Disconnection of oil level gauge
●
Open stuck, breakage, hose disconnection, or cracks of PCV valve
●
Disconnection or cracks of EVAP purge hose, open stuck of EVAP canister purge volume control solenoid
valve
●
Malfunctioning seal of rocker cover gasket
●
Disconnection, looseness, or cracks of hoses, such as vacuum hose, connecting to intake air system
parts
●
Malfunctioning seal of intake air system, etc.
>> GO TO 30.
29.
CHECK “A/F ALPHA-B1”, “A/F ALPHA-B2”, AND “B/FUEL SCHDL”
Select “A/F ALPHA-B1”, “A/F ALPHA-B2”, and “B/FUEL SCHDL” in “DATA MONITOR (SPEC)” mode, and
make sure that the each indication is within the SP value.
OK or NG
OK
>> INSPECTION END
NG
>> Detect malfunctioning part according to
PBIB2370E
EC-144
TROUBLE DIAGNOSIS - SPECIFICATION VALUE
30.
CHECK “B/FUEL SCHDL”
Select “B/FUEL SCHDL” in “DATA MONITOR (SPEC)” mode, and then make sure that the indication is within
the SP value.
OK or NG
OK
>> INSPECTION END
NG
>> Detect malfunctioning part according to
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT
EC-145
C
D
E
F
G
H
I
J
K
L
M
A
EC
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT
PFP:00006
Description
NBS001RG
Intermittent incidents may occur. In many cases, the malfunction resolves itself (the part or circuit function
returns to normal without intervention). It is important to realize that the symptoms described in the customer's
complaint often do not recur on (1st trip) DTC visits. Realize also that the most frequent cause of intermittent
incidents occurrences is poor electrical connections. Because of this, the conditions under which the incident
occurred may not be clear. Therefore, circuit checks made as part of the standard diagnostic procedure may
not indicate the specific malfunctioning area.
Common Intermittent Incidents Report Situations
Diagnostic Procedure
NBS001RH
1.
INSPECTION START
Erase (1st trip) DTCs. Refer to
EC-61, "HOW TO ERASE EMISSION-RELATED DIAGNOSTIC INFORMA-
>> GO TO 2.
2.
CHECK GROUND TERMINALS
Check ground terminals for corroding or loose connection.
Refer to
.
OK or NG
OK
>> GO TO 3.
NG
>> Repair or replace.
3.
SEARCH FOR ELECTRICAL INCIDENT
Perform
GI-26, "How to Perform Efficient Diagnosis for an Electrical Incident"
, “INCIDENT SIMULATION
TESTS”.
OK or NG
OK
>> GO TO 4.
NG
>> Repair or replace.
4.
CHECK CONNECTOR TERMINALS
Refer to
GI-23, "How to Check Terminal"
, “HOW TO PROBE CONNECTORS”, “How to Check Enlarged Con-
tact Spring of Terminal”.
OK or NG
OK
>> INSPECTION END
NG
>> Repair or replace connector.
STEP in Work Flow
Situation
2
The CONSULT-II is used. The SELF-DIAG RESULTS screen shows time data other than [0] or [1t].
3 or 4
The symptom described by the customer does not recur.
5
(1st trip) DTC does not appear during the DTC Confirmation Procedure.
10
The Diagnostic Procedure for PXXXX does not indicate the malfunctioning area.
EC-146
POWER SUPPLY AND GROUND CIRCUIT
POWER SUPPLY AND GROUND CIRCUIT
PFP:24110
Wiring Diagram
NBS001RI
TBWM1216E