Infiniti G37 Coupe. Manual — part 1205
SRC-70
< COMPONENT DIAGNOSIS >
B1083 PRE-TEN FRONT RH
>> GO TO 2.
2.
CHECK AIR BAG WARNING LAMP
Check the warning lamp status.
Is malfunctioning part detected?
YES
>> Refer to
.
NO
>> INSPECTION END.
Diagnosis Procedure (Component diagnosis)
INFOID:0000000001694556
With CONSULT-lll
WARNING:
• Before servicing, turn ignition switch OFF, disconnect both battery terminals and wait at least 3 min-
utes. (To discharge backup capacitor.)
• Do not use unspecified tester or other measuring device.
DIAGNOSTIC PROCEDURE
1.
CHECK HARNESS CONNECTOR
Check the connection of harness connector.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace harness connector.
2.
CHECK WIRING HARNESS
Check the wiring harness externals.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair or replace wiring harness.
3.
CHECK FRONT SEAT BELT PRE-TENSIONER
1.
Replace front RH seat belt pre-tensioner.
2.
Check the screen of CONSULT-lll.
Is the inspection result normal?
YES
>> INSPECTION END.
NO
>> Check the intermittent incident. Refer to
GI-38, "Intermittent Incident"
.
B1084 PRE-TEN FRONT RH
SRC-71
< COMPONENT DIAGNOSIS >
C
D
E
F
G
I
J
K
L
M
A
B
SRC
N
O
P
B1084 PRE-TEN FRONT RH
Description
INFOID:0000000001694557
DTC B1084 [SHORT] PRE-TEN FRONT RH
For front RH seat belt pre-tensioner, crash is judged by main “G” sensor output signal and sub “G” sensor in
front direction.
OPERATION
In the case of a frontal collision that exceeds specified impact level, the diagnosis sensor unit detects the
deceleration caused by collision. If restrains the passenger with seat belt easing the stress on passengers
chest with load limiter.
STRUCTURE
The restraint system for front seat occupant consists of the pre-tensioner mechanism and load limiter mecha-
nism.
INSTALLATION
Front RH seat belt pre-tensioner is installed on the underside of center pillar with fixed nuts.
DTC Logic
INFOID:0000000001694558
DTC DETECTION LOGIC
With CONSULT-lll
DTC No. Index (“SELF-DIAG [CURRENT]”), (“SELF-DIAG [PAST]” or “TROUBLE DIAG RECORD”)
DTC CONFIRMATION PROCEDURE (With CONSULT-lll)
1.
INSPECTION START
Turn ignition switch ON.
>> GO TO 2.
2.
CHECK SELF-DIAG RESULT
Check the screen of CONSULT-lll.
Is malfunctioning part detected?
YES
>> Refer to
SRC-72, "Diagnosis Procedure (Component diagnosis)"
NO
>> INSPECTION END.
DTC CONFIRMATION PROCEDURE (Without CONSULT-lll)
NOTE:
• SRS will not enter diagnosis mode if no malfunction is detected in user mode.
1.
INSPECTION START
Turn ignition switch ON.
DTC No.
Trouble diagnosis name
DTC detecting condition
Possible cause
B1084
PRE-TEN FRONT RH
[SHORT]
Front RH seat belt pre-tensioner circuit
are shorted to each other.
• Disconnection of wiring harness and
short.
• Internal breakdown in front RH seat
belt pre-tensioner.
• Internal breakdown in diagnosis sen-
sor unit (ACU).
SRC-72
< COMPONENT DIAGNOSIS >
B1084 PRE-TEN FRONT RH
>> GO TO 2.
2.
CHECK AIR BAG WARNING LAMP
Check the warning lamp status.
Is malfunctioning part detected?
YES
>> Refer to
.
NO
>> INSPECTION END.
Diagnosis Procedure (Component diagnosis)
INFOID:0000000001694559
With CONSULT-lll
WARNING:
• Before servicing, turn ignition switch OFF, disconnect both battery terminals and wait at least 3 min-
utes. (To discharge backup capacitor.)
• Do not use unspecified tester or other measuring device.
DIAGNOSTIC PROCEDURE
1.
CHECK HARNESS CONNECTOR
Check the connection of harness connector.
Is the inspectiion result normal?
YES
>> GO TO 2.
NO
>> Repair or replace harness connector.
2.
CHECK WIRING HARNESS
Check the wiring harness externals.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair or replace wiring harness.
3.
CHECK FRONT SEAT BELT PRE-TENSIONER
1.
Replace front RH seat belt pre-tensioner.
2.
Check the screen of CONSULT-lll.
Is the inspection result normal?
YES
>> INSPECTION END.
NO
>> Check the intermittent incident. Refer to
GI-38, "Intermittent Incident"
.
B1086 PRE-TEN FRONT LH
SRC-73
< COMPONENT DIAGNOSIS >
C
D
E
F
G
I
J
K
L
M
A
B
SRC
N
O
P
B1086 PRE-TEN FRONT LH
Description
INFOID:0000000001694560
DTC B1086 [OPEN] PRE-TEN FRONT LH
For front LH seat belt pre-tensioner, crash is judged by main “G” sensor output signal and sub “G” sensor in
front direction.
OPERATION
In the case of a frontal collision that exceeds specified impact level, the diagnosis sensor unit detects the
deceleration caused by collision. If restrains the passenger with seat belt easing the stress on passengers
chest with load limiter.
STRUCTURE
The restraint system for front seat occupant consists of the pre-tensioner mechanism and load limiter mecha-
nism.
INSTALLATION
Front LH seat belt pre-tensioner is installed on the underside of center pillar with fixed nuts.
DTC Logic
INFOID:0000000001694561
DTC DETECTION LOGIC
With CONSULT-lll
DTC No. Index (“SELF-DIAG [CURRENT]”), (“SELF-DIAG [PAST]” or “TROUBLE DIAG RECORD”)
DTC CONFIRMATION PROCEDURE (With CONSULT-lll)
1.
INSPECTION START
Turn ignition switch ON.
>> GO TO 2.
2.
CHECK SELF-DIAG RESULT
Check the screen of CONSULT-lll.
Is malfunctioning part detected?
YES
>> Refer to
SRC-74, "Diagnosis Procedure (Component diagnosis)"
NO
>> INSPECTION END.
DTC CONFIRMATION PROCEDURE (Without CONSULT-lll)
NOTE:
• SRS will not enter diagnosis mode if no malfunction is detected in user mode.
1.
INSPECTION START
Turn ignition switch ON.
DTC No.
Trouble diagnosis name
DTC detecting condition
Possible cause
B1086
PRE-TEN FRONT LH
[OPEN]
Front LH seat belt pre-tensioner circuit
is open.
• Disconnection of wiring harness and
open.
• Internal breakdown in front LH seat
belt pre-tensioner.
• Internal breakdown in diagnosis sen-
sor unit (ACU).