Infiniti G37 Coupe. Manual — part 1057
SUNROOF DOES NOT OPERATE PROPERLY
RF-53
< SYMPTOM DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
RF
N
O
P
SYMPTOM DIAGNOSIS
SUNROOF DOES NOT OPERATE PROPERLY
Diagnosis Procedure
INFOID:0000000001693841
1.
CHECK BCM POWER SUPPLY AND GROUND CIRCUIT
Check BCM power supply and ground circuit.
Refer to
RF-9, "BCM : Diagnosis Procedure"
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace the malfunctioning parts.
2.
CHECK SUNROOF MOTOR ASSEMBLY POWER SUPPLY AND GROUND CIRCUIT
Check sunroof motor assembly power supply and ground circuit.
Refer to
RF-9, "SUNROOF MOTOR ASSEMBLY : Diagnosis Procedure"
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair or replace the malfunctioning parts.
3.
CHECK SUNROOF SWITCH
Check sunroof switch.
Refer to
RF-12, "Component Function Check"
.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace the malfunctioning parts.
4.
CONFIRM THE OPERATION
Confirm the operation again.
Is the result normal?
YES
>> Check intermittent incident. Refer to
GI-38, "Intermittent Incident"
.
NO
>> GO TO 1.
RF-54
< SYMPTOM DIAGNOSIS >
AUTO OPERATION DOES NOT OPERATE
AUTO OPERATION DOES NOT OPERATE
Diagnosis Procedure
INFOID:0000000001693842
1.
PERFORM INITIALIZATION PROCEDURE
Initialization procedure is executed and operation is confirmed.
Refer to
RF-4, "ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Special Repair Requirement"
.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> GO TO 2.
2.
CONFIRM THE OPERATION
Confirm the operation again.
Is the result normal?
YES
>> Check intermittent incident. Refer to
GI-38, "Intermittent Incident"
.
NO
>> GO TO 1.
DOES NOT STOP FULLY-OPEN OR FULLY-CLOSED POSITION
RF-55
< SYMPTOM DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
RF
N
O
P
DOES NOT STOP FULLY-OPEN OR FULLY-CLOSED POSITION
Diagnosis Procedure
INFOID:0000000001693843
1.
PERFORM INITIALIZATION PROCEDURE
Initialization procedure is executed and operation is confirmed.
Refer to
RF-4, "ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Special Repair Requirement"
.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> GO TO 2.
2.
CONFIRM THE OPERATION
Confirm the operation again.
Is the result normal?
YES
>> Check intermittent incident. Refer to
GI-38, "Intermittent Incident"
.
NO
>> GO TO 1.
RF-56
< SYMPTOM DIAGNOSIS >
RETAINED POWER OPERATION DOES NOT OPERATE PROPERLY
RETAINED POWER OPERATION DOES NOT OPERATE PROPERLY
Diagnosis Procedure
INFOID:0000000001693844
1.
CHECK DOOR SWITCH
Check door switch.
Refer to
RF-14, "Component Function Check"
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace the malfunctioning parts.
2.
CONFIRM THE OPERATION
Confirm the operation again.
Is the result normal?
YES
>> Check intermittent incident. Refer to
GI-38, "Intermittent Incident"
.
NO
>> GO TO 1.