DTC P0134, P0154 HO2S1
EC-241
C
D
E
F
G
H
I
J
K
L
M
A
EC
6.
Check the following.
●
“HO2S1 MNTR (B1)/(B2)” in “DATA MONITOR” mode
changes from “RICH” to “LEAN” to “RICH” more than 5 times
in 10 seconds.
5 times (cycles) are counted as shown at right.
●
“HO2S1 (B1)/(B2)” voltage goes above 0.6V at least once.
●
“HO2S1 (B1)/(B2)” voltage goes below 0.3V at least once.
●
“HO2S1 (B1)/(B2)” voltage never exceeds 1.0V.
CAUTION:
●
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7
in) onto a hard surface such as a concrete floor; use a new one.
●
Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread
Cleaner tool J-43897-18 or J-43897-12 and approved anti-seize lubricant.
Without CONSULT-II
1.
Start engine and warm it up to normal operating temperature.
2.
Set voltmeter probes between ECM terminal 114 [HO2S1 (B1) signal] or 115 [HO2S1 (B2) signal] and
engine ground.
3.
Check the following with engine speed held at 2,000 rpm con-
stant under no load.
●
The voltage fluctuates between 0 to 0.3V and 0.6 to 1.0V
more than 5 times within 10 seconds.
●
The maximum voltage is over 0.6V at least 1 time.
●
The minimum voltage is below 0.3V at least 1 time.
●
The voltage never exceeds 1.0V.
1 time: 0 - 0.3V
→
0.6 - 1.0V
→
0 - 0.3V
2 times: 0 - 0.3V
→
0.6 - 1.0V
→
0 - 0.3V
→
0.6 - 1.0V
→
0 -
0.3V
CAUTION:
●
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7
in) onto a hard surface such as a concrete floor; use a new one.
●
Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread
Cleaner tool J-43897-18 or J-43897-12 and approved anti-seize lubricant.
Removal and Installation
EBS00LZN
HEATED OXYGEN SENSOR 1
Refer to
EM-22, "EXHAUST MANIFOLD AND THREE WAY CATALYST"
SEF647Y
SEF648Y
PBIB0063E
EC-242
DTC P0138, P0158 HO2S2
DTC P0138, P0158 HO2S2
PFP:226A0
Component Description
EBS00LZO
The heated oxygen sensor 2, after three way catalyst (manifold),
monitors the oxygen level in the exhaust gas on each bank.
Even if switching characteristics of the heated oxygen sensor 1 are
shifted, the air-fuel ratio is controlled to stoichiometric, by the signal
from the heated oxygen sensor 2.
This sensor is made of ceramic zirconia. The zirconia generates volt-
age from approximately 1V in richer conditions to 0V in leaner condi-
tions.
Under normal conditions the heated oxygen sensor 2 is not used for
engine control operation.
CONSULT-II Reference Value in Data Monitor Mode
EBS00LZP
Specification data are reference values.
On Board Diagnosis Logic
EBS00LZQ
The heated oxygen sensor 2 has a much longer switching time
between rich and lean than the heated oxygen sensor 1. The oxygen
storage capacity before the three way catalyst (manifold) causes the
longer switching time. To judge the malfunctions of heated oxygen
sensor 2, ECM monitors whether the voltage is unusually high during
the various driving condition such as fuel-cut.
SEF327R
MONITOR ITEM
CONDITION
SPECIFICATION
HO2S2 (B1)
HO2S2 (B2)
●
Warm-up condition
●
After keeping the engine speed
between 3,500 and 4,000 rpm for 1
minute and at idle for 1 minute
under no load
Revving engine from idle up to
3,000 rpm quickly.
0 - 0.3V
←→
Approx. 0.6 - 1.0V
HO2S2 MNTR (B1)
HO2S2 MNTR (B2)
●
Warm-up condition
●
After keeping the engine speed
between 3,500 and 4,000 rpm for 1
minute and at idle for 1 minute
under no load
Revving engine from idle up to
3,000 rpm quickly.
LEAN
←→
RICH
SEF305UA
DTC No.
Trouble diagnosis name
DTC detecting condition
Possible cause
P0138
0138
(Bank 1)
Heated oxygen sensor 2
circuit high voltage
An excessively high voltage from the sensor
is sent to ECM.
●
Harness or connectors
(The sensor circuit is open or shorted)
●
Heated oxygen sensor 2
P0158
0158
(Bank 2)
DTC P0138, P0158 HO2S2
EC-243
C
D
E
F
G
H
I
J
K
L
M
A
EC
DTC Confirmation Procedure
EBS00LZR
CAUTION:
Always drive vehicle at a safe speed.
NOTE:
If “DTC Confirmation Procedure” has been previously conducted, always turn ignition switch “OFF” and wait at
least 10 seconds before conducting the next test.
WITH CONSULT-II
1.
Turn ignition switch “ON” and select “DATA MONITOR” mode
with CONSULT-II.
2.
Start engine and warm it up to the normal operating tempera-
ture.
3.
Turn ignition switch “OFF” and wait at least 10 seconds.
4.
Start engine and keep the engine speed between 3,500 and
4,000 rpm for at least 1 minute under no load.
5.
Let engine idle for 2 minutes.
6.
If 1st trip DTC is detected, go to
EC-247, "Diagnostic Procedure"
.
WITH GST
1.
Start engine and warm it up to the normal operating temperature.
2.
Turn ignition switch “OFF” and wait at least 10 seconds.
3.
Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least one minute under no
load.
4.
Let engine idle for one minutes.
5.
Turn ignition switch “OFF” and wait at least 10 seconds.
6.
Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1 minute under no load.
7.
Let engine idle for 2 minutes.
8.
Select “Mode 3” with GST.
9.
EC-247, "Diagnostic Procedure"
.
●
When using GST, “DTC Confirmation Procedure” should be performed twice as much as when
using CONSULT-II because GST cannot display MODE 7 (1st trip DTC) concerning this diagnosis.
Therefore, using CONSULT-II is recommended.
SEF174Y
EC-244
DTC P0138, P0158 HO2S2
Wiring Diagram
EBS00LZS
BANK 1
TBWM0147E
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст