Infiniti F50. Manual — part 12
LASER BEAM AIMING ADJUSTMENT
ACS-41
[ICC]
C
D
E
F
G
H
I
J
L
M
A
B
ACS
5.
Pivot the edge of the target board 20
°
to either side.
NOTE:
50 mm(2 in) shift rates the 20
°
movement.
6.
Do not place anything in the space shown in the figure (view from top).
NOTE:
In case the space shown in the illustration is not available, make space by covering the side of the target
board with a 400 mm(15.75 in)-size frosted black board or black cloth.
Aiming Adjustment
EKS003OZ
CAUTION:
Complete all necessary work for laser beam adjustment until the adjustment completes as shown in
the procedure. If the procedure does not complete, the ICC system is inoperable.
1.
Turn ignition switch OFF.
2.
Connect CONSULT-II and CONSULT-ll CONVERTER on the
data link connector.
SKIA1214E
SKIA1215E
SKIA1216E
SHIA0179E
ACS-42
[ICC]
LASER BEAM AIMING ADJUSTMENT
3.
Start the engine, wait for at least 10 sec., and touch
“START(NISSAN BASED VHCL)”
4.
Touch “ICC”.
If “ICC” is not indicated, go to
5.
Touch “WORK SUPPORT”.
6.
Touch “LASER BEAM ADJUST”.
7.
Touch “START”.
CAUTION:
If the adjustment screen does not appear on CONSULT-II 10
sec. After touching “LASER BEAM ADJUST” screen, the
following causes may be considered:
●
Target is not set accurately.
●
There is not enough space beside the target.
●
Deformation of vehicle or the surrounding equipment
unit, bracket, or the surrounding equipment is causing
inappropriate installation of sensor and aiming may be
set out of the adjustable range.
SKIA3098E
SKIA1217E
SKIA1218E
SKIA1219E
SKIA1220E
LASER BEAM AIMING ADJUSTMENT
ACS-43
[ICC]
C
D
E
F
G
H
I
J
L
M
A
B
ACS
●
The area is not suitable for the adjustment work.
●
ICC sensor is not clean.
8.
After the CONSULT-II displays “ADJUST THE VERTICAL OF
LASER” turn the up-down direction adjustment screw until “U/D
CORRECT” value is set in the range of
±
4.
CAUTION:
Turn the screw slowly. The value change on display is
slower than actual movement of the ICC sensor. Wait for 2
seconds every time the screw is turned half a rotation.
NOTE:
Turning the screw to the right lowers the aiming and to the left
lifts the aiming.
9.
When “U/D CORRECT” value indicates
±
4, confirm that the margin of value remains within
±
4 at least for
2 seconds with no equipment or hand touching the ICC sensor.
When “COMPLETED THE VERTICAL AIMING OF LASER
BEAM” appears on screen, touch “END”.
CAUTION:
Be sure that the margin of “U/D CORRECT” is within
±
4 with
ICC sensor unit is untouched.
10. Confirm that “ADJUSTING AUTOMATIC HORIZONTAL LASER
BEAM AIMING” is on screen and wait for a while (maximum: 10
sec).
SKIA1221E
PKIA2299E
SKIA1223E
SKIA1224E
ACS-44
[ICC]
LASER BEAM AIMING ADJUSTMENT
11. Confirm that “NORMALLY COMPLETED” is displayed on CON-
SULT-II and close the aiming adjustment procedure by touching
“END”.
CAUTION:
Complete all the procedures once “LASER BEAM ADJUST”
mode is entered in CONSULT-II. When the procedure is dis-
continued, the ICC system is inoperable.
CHECK AFTER THE ADJUSTMENT
Test the ICC system operation by running test. Refer to
ACS-37, "ICC system running test"