Infiniti QX56 (Z62). Manual — part 768
COMPONENT PARTS
HA-13
< SYSTEM DESCRIPTION >
C
D
E
F
G
H
J
K
L
M
A
B
HA
N
O
P
SYSTEM DESCRIPTION
COMPONENT PARTS
Component Parts Location
INFOID:0000000006276144
Component Description
INFOID:0000000006276145
JMIIA0920ZZ
1.
Condenser
2.
Refrigerant pressure sensor
3.
Liquid tank
4.
Compressor
5.
Front evaporator
6.
Front expansion valve
7.
Rear evaporator
8.
Rear expansion valve
A.
Built-in heater & cooling unit assem-
bly
B.
Built-in rear coolier unit assembly
Component
Description
Evaporator
The mist form liquid refrigerant transforms to gas by evaporation by the air conveyed from blower
motor. The air is cooled by the heat by evaporation.
Condenser
Cools refrigerant discharged from compressor, and transforms it to liquid refrigerant.
Compressor
Intakes, compresses, and discharges refrigerant, to circulate refrigerant inside the refrigerant cycle.
Refrigerant pressure sensor
Refer to
EC-32, "Refrigerant Pressure Sensor"
.
Liquid tank
Eliminates foreign matter in refrigerant, and stores temporarily liquid refrigerant.
Expansion valve
Transforms high-pressure liquid refrigerant to mist form low-pressure liquid refrigerant by drawing
function.
HA-14
< SYSTEM DESCRIPTION >
SYSTEM
SYSTEM
System Diagram
INFOID:0000000006276146
System Description
INFOID:0000000006276147
REFRIGERANT CYCLE
Refrigerant Flow
JMIIA0921GB
SYSTEM
HA-15
< SYSTEM DESCRIPTION >
C
D
E
F
G
H
J
K
L
M
A
B
HA
N
O
P
The refrigerant from the compressor, frows the condenser with liquid tank, the evaporator, and returns to the
compressor. The refrigerant evaporation in the evaporator is controlled by an expansion valve.
Freeze Protection
Automatic air conditioner
• When intake sensor detects that evaporator surface temperature is 2.5
°
C (37
°
F) or less, A/C auto amp.
requests BCM to turn the compressor OFF.
• BCM requests ECM to turn the compressor to OFF by the signal from A/C auto amp., and ECM makes A/C
relay to OFF, and stops the compressor.
REFRIGERANT SYSTEM PROTECTION
Refrigerant Pressure Sensor
• The refrigerant system is protected against excessively high- or low-pressures by the refrigerant pressure
sensor, installed at the condenser exit. The refrigerant pressure sensor detects the pressure inside the
refrigerant line and sends the voltage signal to the ECM if the system pressure rises above, or falls below
the specifications.
• ECM turns the A/C relay to OFF and stops the compressor when the high-pressure side detected by refriger-
ant pressure sensor is following conditions;
- Approximately 3,120 kPa (31.8 kg/cm
2
, 452 psi) or more (Engine speed is less than 1,500 rpm.)
- Approximately 2,740 kPa (27.9 kg/cm
2
, 397 psi) or more (Engine speed is 1,500 rpm or more.)
- Approximately 140 kPa (1.4 kg/cm
2
, 20 psi) or less
Pressure Relief Valve
The refrigerant system is also protected by a pressure relief valve, located in the rear head of the compressor.
The release port on the pressure relief valve automatically opens and releases refrigerant into the atmosphere
when the pressure of refrigerant in the system increases to an unusual level [more than 3,800 kPa (38.8 kg/
cm
2
, 551 psi)].
HA-16
< BASIC INSPECTION >
DIAGNOSIS AND REPAIR WORKFLOW
BASIC INSPECTION
DIAGNOSIS AND REPAIR WORKFLOW
Work Flow
INFOID:0000000006276148
OVERALL SEQUENCE
DETAILED FLOW
1.
INTERVIEW FOR MALFUNCTION
Interview the symptom to the customer.
NNIIA0143GB
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст