Infiniti QX56 (Z62). Manual — part 1021
PG-162
< BASIC INSPECTION >
FUSE INSPECTION
FUSE INSPECTION
How To Check
INFOID:0000000006275774
• If fuse is blown, be sure to eliminate cause of malfunction before
installing new fuse.
• Use fuse of specified rating. Never use fuse of more than specified
rating.
• Do not partially install fuse; always insert it into fuse holder prop-
erly.
• Remove fuse for “ELECTRICAL PARTS (BAT)” if vehicle is not
used for a long period of time.
CEL083
PG
FUSIBLE LINK INSPECTION
PG-163
< BASIC INSPECTION >
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
FUSIBLE LINK INSPECTION
How To Check
INFOID:0000000006275775
A melted fusible link can be detected either by visual inspection or by feeling with finger tip. If its condition is
questionable, use circuit tester or test lamp.
CAUTION:
• If fusible link should melt, it is possible that critical circuit (power supply or large current carrying
circuit) is shorted. In such a case, carefully check and eliminate cause of malfunction.
• Never wrap outside of fusible link with vinyl tape. Important: Never let fusible link touch any other
wiring harness, vinyl or rubber parts.
1.
Fusible link
JSMIA0237ZZ
PG-164
< REMOVAL AND INSTALLATION >
BATTERY
REMOVAL AND INSTALLATION
BATTERY
Exploded View
INFOID:0000000006275779
Removal and Installation
INFOID:0000000006275780
REMOVAL
1.
Remove cover of battery positive terminal.
2.
Loosen battery terminal nuts, and disconnect both battery cables from battery terminals.
CAUTION:
When disconnecting, disconnect the battery cable from the negative terminal first.
3.
Remove battery fix frame mounting nuts and battery fix frame.
4.
Remove battery.
INSTALLATION
Install in the reverse order of removal.
CAUTION:
When connecting, connect the battery cable to the positive terminal first.
Reset electronic systems as necessary. Refer to
GI-65, "ADDITIONAL SERVICE WHEN REMOVING BAT-
TERY NEGATIVE TERMINAL : Required Procedure After Battery Disconnection"
1
: Battery fix frame
for symbols in the figure.
JSMIA0238GB
PG
BATTERY TERMINAL WITH FUSIBLE LINK
PG-165
< REMOVAL AND INSTALLATION >
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
BATTERY TERMINAL WITH FUSIBLE LINK
Exploded View
INFOID:0000000006275781
Removal and Installation
INFOID:0000000006275782
REMOVAL
1.
Disconnect the battery cable from the negative terminal.
2.
Remove cover of battery positive terminal.
3.
Remove harness mounting nut and battery terminal with fusible link mounting nut.
4.
Disconnect harness connector and remove battery terminal with fusible link.
INSTALLATION
Install in the reverse order of removal.
1
: Battery terminal with fusible link
2
: Harness connector
for symbols in the figure.
JSMIA0239GB