Infiniti QX56 (Z62). Manual — part 407
DLK-94
< DTC/CIRCUIT DIAGNOSIS >
B2419 OPEN SWITCH
NO
>> Replace back door lock assembly.
B2420 CLOSE SWITCH
DLK-95
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
B2420 CLOSE SWITCH
DTC Logic
INFOID:0000000006225894
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
PERFORM DTC CONFIRMATION PROCEDURE
1.
Turn ignition switch ON.
2.
Check “Self Diagnostic Result” mode of “AUTOMATIC BACK DOOR CONTROL UNIT” using CONSULT-
III.
Is DTC detected?
YES
>> Refer to
.
NO
>> INSPECTION END
Diagnosis Procedure
INFOID:0000000006225895
1.
CHECK CLOSE SWITCH SIGNAL
1.
Select “AUTOMATIC BACK DOOR CONTROL UNIT” using CONSULT-III.
2.
Select “CLOSE SW” in “DATA MONITOR” mode.
3.
Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> GO TO 2.
2.
CHECK AUTOMATIC BACK DOOR CONTROL MODULE OUTPUT SIGNAL
1.
Turn ignition switch OFF.
2.
Disconnect back door lock assembly connector.
3.
Check voltage between back door lock assembly harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> GO TO 3.
3.
CHECK CLOSE SWITCH CIRCUIT
1.
Disconnect automatic back door control module connector.
2.
Check continuity between automatic back door control module harness connector and back door lock
assembly harness connector.
DTC
CONSULT-III display
description
DTC detecting condition
Possible cause
B2420
CLOSE SW
When the automatic back door control unit detects
any of the following conditions
• The change of close switch cannot be detected
for 3 second or more after starting the closure
close output for the 3rd time in a row
• Close switch
• Harness or connectors
(Close switch circuit is open or
shorted)
• Automatic back door control mod-
ule
Monitor item
Condition
Status
CLOSE SW
Back door
Open/Half latch
OFF
Fully closed
ON
(+)
(–)
Voltage
(Approx.)
Back door lock assembly
Connector
Terminal
D157
5
Ground
Battery voltage
DLK-96
< DTC/CIRCUIT DIAGNOSIS >
B2420 CLOSE SWITCH
3.
Check continuity between automatic back door control module harness connector and ground.
Is the inspection result normal?
YES
>> Replace automatic back door control module. Refer to
DLK-262, "Removal and Installation"
.
NO
>> Repair or replace harness.
4.
CHECK CLOSE SWITCH GROUND CIRCUIT
Check continuity between back door lock assembly harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Repair or replace harness.
5.
CHECK CLOSE SWITCH
.
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> Replace back door lock assembly.
6.
CHECK INTERMITTENT INCIDENT
GI-40, "Intermittent Incident"
>> INSPECTION END
Component Inspection
INFOID:0000000006225896
COMPONENT INSPECTION
1.
CHECK CLOSE SWITCH
1.
Turn ignition switch OFF.
2.
Disconnect back door lock assembly.
3.
Check continuity between back door lock assembly terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace back door lock assembly.
Automatic back door control module
Back door lock assembly
Continuity
Connector
Terminal
Connector
Terminal
B26
19
D157
5
Existed
Automatic back door control module
Ground
Continuity
Connector
Terminal
B26
19
Not existed
Back door lock assembly
Ground
Continuity
Connector
Terminal
D157
8
Existed
Back door lock assembly
Condition
Continuity
Terminal
5
8
Back door
Fully closed
Existed
Open/Half latch
Not existed
B2421 CLUTCH OPERATION TIME
DLK-97
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
B2421 CLUTCH OPERATION TIME
DTC Logic
INFOID:0000000006225897
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
PERFORM DTC CONFIRMATION PROCEDURE
1.
Turn ignition switch ON.
2.
Check “Self Diagnostic Result” mode of “AUTOMATIC BACK DOOR CONTROL UNIT” using CONSULT-
III.
Is DTC detected?
YES
>> Refer to
.
NO
>> INSPECTION END
Diagnosis Procedure
INFOID:0000000006225898
1.
CHECK AUTOMATIC BACK DOOR CONTROL MODULE POWER SUPPLY AND GROUND CIRCUIT
1.
Turn ignition switch OFF.
2.
Check automatic back door control module power supply and ground circuit.
Refer to
DLK-116, "AUTOMATIC BACK DOOR CONTROL UNIT : Diagnosis Procedure"
.
Is the inspection result normal?
YES
>> Replace automatic back door control module. Refer to
DLK-262, "Removal and Installation"
.
NO
>> Repair or replace the malfunctioning parts.
DTC
CONSULT-III display
description
DTC detecting condition
Possible cause
B2421
CLUTCH TIME OUT
When the automatic back door control unit detects
the power distribution to the clutch for 2 minutes or
more
• Automatic back door control mod-
ule
• Battery voltage (low voltage)
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.