Infiniti QX56 (Z62). Manual — part 1026
PWC-16
< ECU DIAGNOSIS INFORMATION >
FRONT POWER WINDOW SWITCH (PASSENGER SIDE)
FRONT POWER WINDOW SWITCH (PASSENGER SIDE)
Reference Value
INFOID:0000000006217274
TERMINAL LAYOUT
PHYSICAL VALUES
FRONT POWER WINDOW SWITCH
JMKIA3330ZZ
Terminal No.
(wire color)
Description
Condition
Voltage [V]
(Approx.)
+
-
Signal name
Input/
Output
3
(W/B)
Ground
Encoder ground
—
—
0
4
(G/R)
Ground
Encoder power supply
Output
When ignition switch ON or
power window timer operates
12
8
(L)
Ground
Power window motor
UP signal
Output
When power window motor is
operated UP
12
9
(G)
Ground
Power window motor
DOWN signal
Output
When power window motor is
operated DOWN
12
10
(W)
Ground
Battery power supply
Input
—
12
11
(B)
Ground
Ground
—
—
0
12
(G/Y)
Ground
Encoder pulse signal 1
Input
When power window motor
operates
JMKIA0070GB
FRONT POWER WINDOW SWITCH (PASSENGER SIDE)
PWC-17
< ECU DIAGNOSIS INFORMATION >
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
Fail-safe
INFOID:0000000006217275
FAIL-SAFE CONTROL
Switches to fail-safe control when malfunction is detected in encoder signal that detects up/down speed and
direction of door glass. Switches to fail-safe control when a signal that is out of the specified value is detected
between the fully closed position and the actual position of the glass.
If fail-safe control, the system changes to a non-initialized condition and the following function do not operate.
• Auto-up operation
• Anti-pinch function
• Retained power function
When fail-safe control is activated, perform initialization procedure to recover. If a malfunction is detected in
power window switch or more, fail-safe control is activated again.
15
(G/W)
Ground
Encoder pulse signal 2
Input
When power window motor
operates
16
(V)
Ground
Power window serial link
Input/
Output
When ignition switch ON or
power window timer operates
Terminal No.
(wire color)
Description
Condition
Voltage [V]
(Approx.)
+
-
Signal name
Input/
Output
JMKIA0070GB
JPMIA0013GB
Malfunction
Malfunction condition
Pulse sensor malfunction
When one pulse signal that is the specified value or more is detected continuously for the specified
time or more, while door glass is being operated UP or DOWN.
Both pulse sensors mal-
function
When both pulse signals are not detected continuously for the specified time or more, while door
glass is being operated UP or DOWN.
Pulse direction malfunc-
tion
When a pulse signal indicating that window is moving in the opposite direction against the power win-
dow motor is detected for the specified value or more, while door glass is being operated UP or
DOWN.
Glass recognition position
malfunction 1
When the actual door glass position that is out of specified value is detected compared to the door
glass fully closed position memorized in module, while door glass is being operated UP or DOWN.
Glass recognition position
malfunction 2
When pulse count that is out of the door glass full stroke value or more is detected, while door glass
is being operated UP or DOWN.
PWC-18
< ECU DIAGNOSIS INFORMATION >
REAR POWER WINDOW SWITCH LH
REAR POWER WINDOW SWITCH LH
Reference Value
INFOID:0000000006217276
TERMINAL LAYOUT
PHYSICAL VALUES
REAR POWER WINDOW SWITCH
JMKIA3330ZZ
Terminal No.
(wire color)
Description
Condition
Voltage [V]
(Approx.)
+
-
Signal name
Input/
Output
3
(SB)
Ground
Encoder ground
—
—
0
4
(LG)
Ground
Encoder power supply
Output
When ignition switch ON or pow-
er window timer operates
12
8
(Y)
Ground
Power window motor
UP signal
Output
When power window motor is
operated UP
12
9
(G)
Ground
Power window motor
DOWN signal
Output
When power window motor is
operated DOWN
12
10
(W)
Ground
Battery power supply
Input
—
12
11
(B)
Ground
Ground
—
—
0
12
(BR)
Ground
Encoder pulse signal 1
Input
When power window motor oper-
ates
JMKIA0070GB
REAR POWER WINDOW SWITCH LH
PWC-19
< ECU DIAGNOSIS INFORMATION >
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
Fail-safe
INFOID:0000000006217277
FAIL-SAFE CONTROL
Switches to fail-safe control when malfunction is detected in encoder signal that detects up/down speed and
direction of door glass. Switches to fail-safe control when a signal that is out of the specified value is detected
between the fully closed position and the actual position of the glass.
If fail-safe control, the system changes to a non-initialized condition and the following function do not operate.
• Auto-up operation
• Anti-pinch function
• Retained power function
When fail-safe control is activated, perform initialization procedure to recover. If a malfunction is detected in
power window switch or more, fail-safe control is activated again.
15
(L)
Ground
Encoder pulse signal 2
Input
When power window motor oper-
ates.
16
(V)
Ground
Power window serial link
Input/
Output
When ignition switch ON or pow-
er window timer operates
Terminal No.
(wire color)
Description
Condition
Voltage [V]
(Approx.)
+
-
Signal name
Input/
Output
JMKIA0070GB
JPMIA0013GB
Malfunction
Malfunction condition
Pulse sensor malfunction
When one pulse signal that is the specified value or more is detected continuously for the specified
time or more, while door glass is being operated UP or DOWN.
Both pulse sensors mal-
function
When both pulse signals are not detected continuously for the specified time or more, while door
glass is being operated UP or DOWN.
Pulse direction malfunc-
tion
When a pulse signal indicating that window is moving in the opposite direction against the power win-
dow motor is detected for the specified value or more, while door glass is being operated UP or
DOWN.
Glass recognition position
malfunction 1
When the actual door glass position that is out of specified value is detected compared to the door
glass fully closed position memorized in module, while door glass is being operated UP or DOWN.
Glass recognition position
malfunction 2
When pulse count that is out of the door glass full stroke value or more is detected, while door glass
is being operated UP or DOWN.
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.