Infiniti QX56 (Z62). Manual — part 676
EX-2
< PRECAUTION >
PRECAUTIONS
PRECAUTION
PRECAUTIONS
Removal and Installation
INFOID:0000000006289691
CAUTION:
• Be sure to use genuine exhaust system parts or equivalents which are specially designed for heat
resistance, corrosion resistance, and shape.
• Perform the operation with the exhaust system fully cooled down because the system will be hot
just after engine stops.
• Be careful not to cut your hand on the heat insulator edge.
PREPARATION
EX-3
< PREPARATION >
C
D
E
F
G
H
I
J
K
L
M
A
EX
N
P
O
PREPARATION
PREPARATION
Special Service Tool
INFOID:0000000006289692
Commercial Service Tool
INFOID:0000000006289693
Tool number
(Kent-Moore No.)
Tool name
Description
KV10114400
(J-38365)
Heated oxygen sensor wrench
Loosening or tightening heated oxygen sen-
sor 2
For 22 mm (0.87 in) (a) width hexagon nut
S-NT636
Tool name
Description
Power tool
Loosening bolts and nuts
PBIC0190E
EX-4
< PERIODIC MAINTENANCE >
EXHAUST SYSTEM
PERIODIC MAINTENANCE
EXHAUST SYSTEM
Inspection
INFOID:0000000006289694
Check exhaust pipes, muffler and mounting for improper attachment,
leakage, cracks, damage or deterioration.
• If damage is found, repair or replace damaged parts.
SMA211A
EXHAUST SYSTEM
EX-5
< REMOVAL AND INSTALLATION >
C
D
E
F
G
H
I
J
K
L
M
A
EX
N
P
O
REMOVAL AND INSTALLATION
EXHAUST SYSTEM
Exploded View
INFOID:0000000006289695
Removal and Installation
INFOID:0000000006289696
REMOVAL
• Disconnect each joint and mounting using power tool.
• Remove heated oxygen sensor 2, as follows:.
1.
Mounting rubber
2.
Mounting bracket
3.
Rear mufller
4.
Dynamic damper
5.
Mounting rubber
6.
Mounting bracket
7.
Mounting rubber
8.
Gasket
9.
Main muffler
10. Mounting rubber
11. Mounting bracket
12. Mounting rubber
13. Gasket
14. Exhaust front tube (RH)
15. Exhaust front tube (LH)
16. Heated oxygen sensor 2 (bank 2)
17. Heated oxygen sensor 2 (bank 1)
18. Ring gasket
JPBIA3265GB