Infiniti QX56 (Z62). Manual — part 976
PCS-60
< DTC/CIRCUIT DIAGNOSIS >
[POWER DISTRIBUTION SYSTEM]
B2615 BLOWER RELAY CIRCUIT
YES
>> GO TO 6.
NO
>> Repair or replace harness.
3.
CHECK BLOWER RELAY GROUND CIRCUIT
1.
Turn ignition switch OFF.
2.
Check continuity between blower relay harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair blower relay ground circuit.
4.
CHECK BLOWER RELAY POWER SUPPLY CIRCUIT-2
1.
Turn ignition switch ON or ACC.
2.
Check voltage between blower relay harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Check continuity open or short between blower relay and battery.
5.
CHECK BLOWER RELAY
PCS-60, "Component Inspection"
.
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> Replace blower relay.
6.
CHECK INTERMITTENT INCIDENT
GI-40, "Intermittent Incident"
>> INSPECTION END
Component Inspection
INFOID:0000000006220208
1.
CHECK BLOWER RELAY
1.
Turn ignition switch OFF.
2.
Remove blower relay.
3.
Check the continuity between blower relay terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace blower relay
Blower relay
Ground
Continuity
Terminal
2
Existed
(+)
(–)
Voltage (V)
(Approx.)
Blower relay
Terminal
5
Ground
Battery voltage
Terminals
Condition
Continuity
3 and 5
12 V direct current supply between terminals 1 and 2
Existed
No current supply
Not existed
PBIB0098E
PCS
B2616 IGNITION RELAY CIRCUIT
PCS-61
< DTC/CIRCUIT DIAGNOSIS >
[POWER DISTRIBUTION SYSTEM]
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
B2616 IGNITION RELAY CIRCUIT
DTC Logic
INFOID:0000000006220209
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
PERFORM DTC CONFIRMATION PROCEDURE
1.
Turn ignition switch ON under the following conditions, and wait for 1 second or more.
-
Selector lever is in the P position
-
Do not depress brake pedal
2.
Check “Self-diagnosis result” of BCM with CONSULT-III.
Is DTC detected?
YES
>> Go to
NO
>> INSPECTION END
Diagnosis Procedure
INFOID:0000000006220210
1.
CHECK IGNITION RELAY-1 POWER SUPPLY
1.
Turn ignition switch OFF.
2.
Disconnect ignition relay-1.
3.
Check voltage between ignition relay-1 harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK IGNITION RELAY-1 POWER SUPPLY CIRCUIT
1.
Turn ignition switch OFF.
2.
Disconnect BCM connector.
3.
Check continuity between ignition relay-1 harness connector and BCM harness connector.
4.
Check continuity between ignition relay-1 harness connector and ground.
Is the inspection result normal?
DTC No.
Trouble diagnosis
name
DTC detecting condition
Possible cause
B2616
BCM
An immediate operation of ignition relay-1 is re-
quested by BCM, but there is no response for more
than 1 second
• Harness or connectors
(Ignition relay-1 circuit is open or
shorted)
• BCM
• Ignition relay-1
(+)
(–)
Condition
Voltage (V)
(Approx.)
Ignition relay-1
Terminal
2
Ground
Ignition switch
OFF or ACC
0
ON
12
Ignition relay-1
BCM
Continuity
Terminal
Connector
Terminal
2
M71
99
Existed
Ignition relay-1
Ground
Continuity
Terminal
2
Not existed
PCS-62
< DTC/CIRCUIT DIAGNOSIS >
[POWER DISTRIBUTION SYSTEM]
B2616 IGNITION RELAY CIRCUIT
YES
>> Replace BCM. Refer to
BCS-81, "Removal and Installation"
NO
>> Repair or replace harness.
3.
CHECK IGNITION RELAY-1 GROUND CIRCUIT
1.
Turn ignition switch OFF.
2.
Check continuity between ignition relay-1 harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair ignition relay-1 ground circuit.
4.
CHECK IGNITION RELAY-1 POWER SUPPLY CIRCUIT-2
1.
Turn ignition switch ON.
2.
Check voltage between ignition relay-1 harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Check continuity open or short between ignition relay-1 and battery.
5.
CHECK IGNITION RELAY-1
PCS-62, "Component Inspection"
.
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> Replace ignition relay-1.
6.
CHECK INTERMITTENT INCIDENT
GI-40, "Intermittent Incident"
>> INSPECTION END
Component Inspection
INFOID:0000000006220211
1.
CHECK IGNITION RELAY-1
1.
Turn ignition switch OFF.
2.
Remove ignition relay-1.
3.
Check the continuity between ignition relay-1 terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace Ignition relay-1.
Ignition relay-1
Ground
Continuity
Terminal
1
Existed
(+)
(–)
Voltage (V)
(Approx.)
Ignition relay-1
Terminal
5
Ground
Battery voltage
Terminals
Condition
Continuity
3 and 5
12 V direct current supply between terminals 1 and 2
Existed
No current supply
Not existed
PBIB0098E
PCS
B2618 BCM
PCS-63
< DTC/CIRCUIT DIAGNOSIS >
[POWER DISTRIBUTION SYSTEM]
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
B2618 BCM
DTC Logic
INFOID:0000000006220212
DTC DETECTION LOGIC
NOTE:
• If DTC B2618 is displayed with DTC U1000, first perform the trouble diagnosis for DTC U1000. Refer to
• If DTC B2618 is displayed with DTC U1010, first perform the trouble diagnosis for DTC U1010. Refer to
DTC CONFIRMATION PROCEDURE
1.
PERFORM DTC CONFIRMATION PROCEDURE
1.
Turn ignition switch ON under the following conditions, and wait for 1 second or more.
-
Selector lever is in the P or N position
-
Do not depress brake pedal
2.
Check “Self-diagnosis result” of BCM with CONSULT-III.
Is DTC detected?
YES
>> Go to
NO
>> INSPECTION END
Diagnosis Procedure
INFOID:0000000006220213
1.
INSPECTION START
1.
Turn ignition switch ON.
2.
Select “Self-diagnosis result” of BCM with CONSULT-III.
3.
Touch “ERASE”.
4.
Perform DTC Confirmation Procedure.
See
.
Is the 1st trip DTC B2618 displayed again?
YES
>> Replace BCM. Refer to
BCS-81, "Removal and Installation"
NO
>> INSPECTION END
DTC No.
Trouble diagnosis
name
DTC detecting condition
Possible cause
B2618
BCM
An immediate operation of ignition relay (IPDM E/R) is re-
quested by BCM, but there is no response for more than
1 second
BCM