Infiniti QX56 (Z62). Manual — part 421
DLK-150
< DTC/CIRCUIT DIAGNOSIS >
AUTOMATIC BACK DOOR CLOSE SWITCH
AUTOMATIC BACK DOOR CLOSE SWITCH
Component Function Check
INFOID:0000000006225971
1.
CHECK FUNCTION
1.
Select “AUTOMATIC BACK DOOR CONTROL UNIT” using CONSULT-III.
2.
Select “BK DOOR CL SW” in “DATA MONITOR” mode.
3.
Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Automatic back door close switch is OK.
NO
>> Refer to
DLK-150, "Diagnosis Procedure"
.
Diagnosis Procedure
INFOID:0000000006225972
1.
CHECK AUTOMATIC BACK DOOR CLOSE SWITCH INPUT SIGNAL
1.
Turn ignition switch OFF.
2.
Disconnect automatic back door close switch connector.
3.
Check voltage between automatic back door close switch harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK AUTOMATIC BACK DOOR CLOSE SWITCH CIRCUIT
1.
Disconnect automatic back door control module connector.
2.
Check continuity between automatic back door control module harness connector and automatic back
door close switch harness connector.
3.
Check continuity between automatic back door control module harness connector and ground.
Is the inspection result normal?
YES
>> Replace automatic back door control module. Refer to
DLK-262, "Removal and Installation"
.
NO
>> Repair or replace harness.
3.
CHECK AUTOMATIC BACK DOOR CLOSE SWITCH GROUND CIRCUIT
Check continuity between automatic back door close switch harness connector and ground.
Monitor item
Condition
Status
BK DOOR CL SW
Automatic back door close switch
Pressed
ON
Released
OFF
(+)
(–)
Voltage
(Approx.)
Automatic back door close switch
Connector
Terminal
D158
1
Ground
Battery voltage
Automatic back door control module
Automatic back door close switch
Continuity
Connector
Terminal
Connector
Terminal
B26
4
D158
1
Existed
Automatic back door control module
Ground
Continuity
Connector
Terminal
B26
4
Not existed
AUTOMATIC BACK DOOR CLOSE SWITCH
DLK-151
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK AUTOMATIC BACK DOOR CLOSE SWITCH
DLK-151, "Component Inspection"
.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace automatic back door close switch.
5.
CHECK INTERMITTENT INCIDENT
GI-40, "Intermittent Incident"
.
>> INSPECTION END
Component Inspection
INFOID:0000000006225973
1.
CHECK AUTOMATIC BACK DOOR CLOSE SWITCH
1.
Turn ignition switch OFF.
2.
Disconnect automatic back door close switch connector.
3.
Check continuity between automatic back door close switch terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace automatic back door close switch.
Automatic back door close switch
Ground
Continuity
Connector
Terminal
D158
2
Existed
Automatic back door close switch
Condition
Continuity
Terminal
1
2
Automatic back door
close switch
Pressed
Existed
Released
Not existed
DLK-152
< DTC/CIRCUIT DIAGNOSIS >
AUTOMATIC BACK DOOR MAIN SWITCH
AUTOMATIC BACK DOOR MAIN SWITCH
Component Function Check
INFOID:0000000006225974
1.
CHECK FUNCTION
1.
Select “AUTOMATIC BACK DOOR CONTROL UNIT” using CONSULT-III.
2.
Select “MAIN SW” in “DATA MONITOR” mode.
3.
Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Automatic back door main switch is OK.
NO
>> Refer to
DLK-152, "Diagnosis Procedure"
.
Diagnosis Procedure
INFOID:0000000006225975
1.
CHECK AUTOMATIC BACK DOOR MAIN SWITCH INPUT SIGNAL
1.
Turn ignition switch OFF.
2.
Disconnect automatic back door main switch connector.
3.
Check voltage between automatic back door main switch harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK AUTOMATIC BACK DOOR MAIN SWITCH CIRCUIT
1.
Disconnect automatic back door control module connector.
2.
Check continuity between automatic back door control module harness connector and automatic back
door main switch harness connector.
3.
Check continuity between automatic back door control module connector and ground.
Is the inspection result normal?
YES
>> Replace automatic back door control module. Refer to
DLK-262, "Removal and Installation"
.
NO
>> Repair or replace harness.
3.
CHECK AUTOMATIC BACK DOOR MAIN SWITCH GROUND CIRCUIT
Check continuity between automatic back door main switch connector and ground.
Monitor item
Condition
Status
MAIN SW
Automatic back door main switch
ON
ON
OFF
OFF
(+)
(–)
Voltage
(Approx.)
Automatic back door main switch
Connector
Terminal
M110
1
Ground
Battery voltage
Automatic back door control module
Automatic back door main switch
Continuity
Connector
Terminal
Connector
Terminal
B26
17
M110
1
Existed
Automatic back door control module
Ground
Continuity
Connector
Terminal
B26
17
Not existed
AUTOMATIC BACK DOOR MAIN SWITCH
DLK-153
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK AUTOMATIC BACK DOOR MAIN SWITCH
DLK-153, "Component Inspection"
.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace automatic back door main switch.
5.
CHECK INTERMITTENT INCIDENT
GI-40, "Intermittent Incident"
.
>> INSPECTION END
Component Inspection
INFOID:0000000006225976
1.
CHECK AUTOMATIC BACK DOOR MAIN SWITCH
1.
Turn ignition switch OFF.
2.
Disconnect automatic back door switch connector.
3.
Check continuity between automatic back door main switch terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace automatic back door main switch.
Automatic back door main switch
Ground
Continuity
Connector
Terminal
M110
3
Existed
Automatic back door main switch
Condition
Continuity
Terminal
1
3
Automatic back door
main switch
ON
Existed
OFF
Not existed