Infiniti QX56 (Z62). Manual — part 957
MWI-82
< SYMPTOM DIAGNOSIS >
THE DOOR OPEN WARNING CONTINUES DISPLAYING, OR DOES NOT DIS-
PLAY
THE DOOR OPEN WARNING CONTINUES DISPLAYING, OR DOES NOT
DISPLAY
Description
INFOID:0000000006221771
• The door open warning is displayed even though all of the doors are closed.
• The door open warning is not displayed even though a door is ajar.
Diagnosis Procedure
INFOID:0000000006221772
1.
CHECK BCM INPUT/OUTPUT SIGNAL
Connect CONSULT-III and check the BCM input signals. Refer to
DLK-117, "Component Function Check"
.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> GO TO 3.
2.
CHECK COMBINATION METER INPUT SIGNAL
Select the “Data Monitor” for the “METER/M&A” and check the “DOOR W/L” monitor value.
Is the inspection result normal?
YES
>> Replace combination meter. Refer to
MWI-85, "Removal and Installation"
NO
>> Replace BCM. Refer to
BCS-81, "Removal and Installation"
3.
CHECK DOOR SWITCH SIGNAL CIRCUIT
Check the door switch signal circuit. Refer to
DLK-117, "Diagnosis Procedure"
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair harness or connector.
4.
CHECK DOOR SWITCH
Perform a unit check for the door switch. Refer to
DLK-119, "Component Inspection"
Is the inspection result normal?
YES
>> Replace combination meter. Refer to
MWI-85, "Removal and Installation"
NO
>> Replace applicable door switch. Refer to
DLK-254, "Removal and Installation"
.
“DOOR W/L”
Door open
: On
Door closed
: Off
MWI
THE AMBIENT TEMPERATURE DISPLAY IS INCORRECT
MWI-83
< SYMPTOM DIAGNOSIS >
C
D
E
F
G
H
I
J
K
L
M
B
A
O
P
THE AMBIENT TEMPERATURE DISPLAY IS INCORRECT
Description
INFOID:0000000006221773
• The displayed ambient air temperature is higher than the actual temperature.
• The displayed ambient air temperature is lower than the actual temperature.
Diagnosis Procedure
INFOID:0000000006221774
NOTE:
Check that the symptom is not applicable to the normal operating condition before starting diagnosis. Refer to
MWI-84, "INFORMATION DISPLAY : Description"
1.
CHECK AMBIENT SENSOR SIGNAL CIRCUIT
Check the ambient sensor signal circuit. Refer to
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair harness or connector.
2.
CHECK A/C AUTO AMP. CONNECTION RECOGNITION SIGNAL CIRCUIT
Check the A/C auto amp. connection recognition signal circuit. Refer to
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair harness or connector.
3.
CHECK AMBIENT SENSOR
Perform the part check for the ambient sensor. Refer to
HAC-78, "Component Inspection"
.
Is the inspection result normal?
YES
>> Replace combination meter. Refer to
MWI-85, "Removal and Installation"
NO
>> Replace ambient sensor. Refer to
MWI-84
< SYMPTOM DIAGNOSIS >
NORMAL OPERATING CONDITION
NORMAL OPERATING CONDITION
INFORMATION DISPLAY
INFORMATION DISPLAY : Description
INFOID:0000000006221775
AMBIENT AIR TEMPERATURE
The displayed ambient air temperature on the information display may differ from the actual temperature
because it is a corrected value calculated from the ambient sensor signal by the combination meter. Refer to
MWI-20, "INFORMATION DISPLAY : System Description"
for details on the correction process.
DISTANCE TO EMPTY
The calculated distance to empty may differ from the actual distance to empty if the refueling amount is
approximately 15 (4 US gal, 3-1/4 Imp gal) or less. This is because the refuel control (moves the fuel gauge
needle quicker than normal judging that the driver is refueling the vehicle) is not performing.
MWI
COMBINATION METER
MWI-85
< REMOVAL AND INSTALLATION >
C
D
E
F
G
H
I
J
K
L
M
B
A
O
P
REMOVAL AND INSTALLATION
COMBINATION METER
Exploded View
INFOID:0000000006221776
REMOVAL
.
DISASSEMBLY
Removal and Installation
INFOID:0000000006221777
REMOVAL
1.
Remove the cluster lid A. Refer to
IP-14, "Removal and Installation"
.
2.
Remove screws and connector, and then remove combination meter.
INSTALLATION
Install in the reverse order of removal.
Disassembly and Assembly
INFOID:0000000006221778
DISASSEMBLY
1.
Remove screws.
2.
Disengage the tabs to separate front cover.
ASSEMBLY
Assemble in the reverse order of disassembly.
1.
Front cover
2.
Unified meter control unit
JSNIA3014ZZ