Infiniti EX35. Manual — part 1205

PWC-84

< ECU DIAGNOSIS >

POWER WINDOW MAIN SWITCH

JCKWM1096GB

POWER WINDOW MAIN SWITCH

PWC-85

< ECU DIAGNOSIS >

C

D

E

F

G

H

I

J

L

M

A

B

PWC

N

O

P

JCKWM1097GB

PWC-86

< ECU DIAGNOSIS >

POWER WINDOW MAIN SWITCH

Fail Safe

INFOID:0000000003573513

FAIL-SAFE CONTROL

Switches to fail-safe control when malfunction is detected in encoder signal that detects up/down speed and
direction of door glass. Switches to fail-safe control when error beyond regulation value is detected between
the fully closed position and the actual position of the glass.

JCKWM1098GB

POWER WINDOW MAIN SWITCH

PWC-87

< ECU DIAGNOSIS >

C

D

E

F

G

H

I

J

L

M

A

B

PWC

N

O

P

It changes to condition before initialization and the following functions do not operate when switched to fail-
safe control.
• Auto-up operation
• Anti-pinch function
• Retained power function

Perform initial operation to recover when switched to fail-safe mode. However, it switches back to fail-safe
control when malfunction is found in power window switch or front power window motor.

Error

Error condition

Pulse sensor malfunction

When only one side of pulse signal is being detected for more than the specified value.

Both pulse sensors mal-
function

When both pulse signals have not been detected for more than the specified value during glass open/
close operation.

Pulse direction malfunction

When the pulse signal that is detected during glass open/close operation detects the opposite condition
of power window motor operating direction.

Glass recognition position
malfunction 1

When it detects the error between glass fully closed position in power window switch memory and actual
fully closed position during glass open/close operation is more than the specified value.

Glass recognition position
malfunction 2

When it detects pulse count more than the value of glass full stroke during glass open/close operation.

Malfunction of not yet up-
dated closed position of
glass

When glass open/close operation is continuously performed without fully closing more than the specified
value (approximately 10 strokes).