Infiniti G35 (V35) Sedan. Manual — part 526
EC-250
< COMPONENT DIAGNOSIS >
[VQ35HR]
P0300, P0301, P0302, P0303, P0304, P0305, P0306 MISFIRE
Is the measurement value within the specification?
YES
>> GO TO 16.
NO
>> Check connectors for rusted terminals or loose connections in the mass air flow sensor circuit or
ground. Refer to
16.
CHECK SYMPTOM MATRIX CHART
Check items on the rough idle symptom in
.
Is the inspection result normal?
YES
>> GO TO 17.
NO
>> Repair or replace.
17.
ERASE THE 1ST TRIP DTC
Some tests may cause a 1st trip DTC to be set.
Erase the 1st trip DTC from the ECM memory after performing the tests. Refer to
.
>> GO TO 18.
18.
CHECK INTERMITTENT INCIDENT
GI-39, "Intermittent Incident"
>> INSPECTION END
2.0 - 6.0 g·m/sec:
at idling
7.0 - 20.0 g·m/sec:
at 2,500 rpm
P0327, P0328, P0332, P0333 KS
EC-251
< COMPONENT DIAGNOSIS >
[VQ35HR]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
P0327, P0328, P0332, P0333 KS
Description
INFOID:0000000000956638
The knock sensor is attached to the cylinder block. It senses engine knocking using a piezoelectric element. A
knocking vibration from the cylinder block is sensed as vibrational pressure. This pressure is converted into a
voltage signal and sent to the ECM.
DTC Logic
INFOID:0000000000956639
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is more than 10V at idle.
>> GO TO 2.
2.
PERFORM DTC CONFIRMATION PROCEDURE
1.
Start engine and run it for at least 5 seconds at idle speed.
2.
Check 1st trip DTC.
Is 1st trip DTC detected?
YES
>> Go to
NO
>> INSPECTION END
Diagnosis Procedure
INFOID:0000000000956640
1.
CHECK GROUND CONNECTION
1.
Turn ignition switch OFF.
2.
Check ground connection M95. Refer to Ground Inspection in
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace ground connection.
2.
CHECK KNOCK SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
1.
Disconnect knock sensor harness connector and ECM harness connector.
2.
Check the continuity between knock sensor harness connector and ECM harness connector.
DTC No.
Trouble diagnosis
name
DTC detected condition
Possible cause
P0327
Knock sensor (bank 1)
circuit low input
An excessively low voltage from the sensor is
sent to ECM.
• Harness or connectors
(The sensor circuit is open or shorted.)
• Knock sensor
P0328
Knock sensor (bank 1)
circuit high input
An excessively high voltage from the sensor
is sent to ECM.
P0332
Knock sensor (bank 2)
circuit low input
An excessively low voltage from the sensor is
sent to ECM.
P0333
Knock sensor (bank 2)
circuit high input
An excessively high voltage from the sensor
is sent to ECM.
EC-252
< COMPONENT DIAGNOSIS >
[VQ35HR]
P0327, P0328, P0332, P0333 KS
3.
Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> GO TO 3.
3.
DETECT MALFUNCTIONING PART
Check the following.
• Harness connectors F9, F201
• Harness for open or short between knock sensor and ECM
>> Repair open circuit or short to power in harness or connectors.
4.
CHECK KNOCK SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1.
Check the continuity between knock sensor harness connector and ECM harness connector.
2.
Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> GO TO 5.
5.
DETECT MALFUNCTIONING PART
Check the following.
• Harness connectors F9, F201
• Harness for open or short between ECM and knock sensor
>> Repair open circuit or short to ground or short to power in harness or connectors.
6.
CHECK KNOCK SENSOR
EC-252, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 7.
NO
>> Replace malfunctioning knock sensor.
7.
CHECK INTERMITTENT INCIDENT
GI-39, "Intermittent Incident"
>> INSPECTION END
Component Inspection
INFOID:0000000000956641
1.
CHECK KNOCK SENSOR
1.
Turn ignition switch OFF.
2.
Disconnect knock sensor harness connector.
3.
Check resistance between knock sensor terminals as follows.
NOTE:
DTC
Knock sensor
ECM
Continuity
Bank
Connector
Terminal
Connector
Terminal
P0327, P0328
1
F203
2
F102
72
Existed
P0332, P0333
2
F202
2
DTC
Knock sensor
ECM
Continuity
Bank
Connector
Terminal
Connector
Terminal
P0327, P0328
1
F203
1
F102
73
Existed
P0332, P0333
2
F202
1
69
P0327, P0328, P0332, P0333 KS
EC-253
< COMPONENT DIAGNOSIS >
[VQ35HR]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
It is necessary to use an ohmmeter which can measure more than 10 M
Ω
.
CAUTION:
Do not use any knock sensors that have been dropped or physically damaged. Use only new ones.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace malfunctioning knock sensor.
Terminals
Resistance
1 and 2
Approx. 532 - 588 k
Ω
[at 20
°
C (68
°
F)]
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.