Infiniti I30 (A33). Manual — part 288
11
CHECK THROTTLE POSITION SENSOR
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Stop engine (ignition switch OFF).
3. Turn ignition switch ON.
4. Select “DATA MONITOR” mode with CONSULT-II.
5. Check voltage of “THRTL POS SEN” under the following conditions.
Voltage measurement must be made with throttle position sensor installed in vehicle.
SEF062Y
OK or NG
OK
©
GO TO 14.
NG
©
GO TO 13.
12
CHECK THROTTLE POSITION SENSOR
Without CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Stop engine (ignition switch OFF).
3. Turn ignition switch ON.
4. Check voltage between ECM terminal 91 (Throttle position sensor signal) and ground.
Voltage measurement must be made with throttle position sensor installed in vehicle.
MTBL0231
OK or NG
OK
©
GO TO 14.
NG
©
GO TO 13.
GI
MA
EM
LC
FE
AT
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P1130 SWIRL CONTROL VALVE CONTROL SOLENOID VALVE
Diagnostic Procedure (Cont’d)
EC-467
13
ADJUST CLOSED THROTTLE POSITION SWITCH
Adjust closed throttle position switch. Refer to “Basic Inspection”, EC-109.
MTBL0595
OK or NG
OK
©
GO TO 14.
NG
©
Replace throttle position sensor. To adjust it, perform “Basic Inspection”, EC-109.
14
CHECK CRANKSHAFT POSITION SENSOR (REF)-I
1. Turn ignition switch “OFF”.
2. Loosen the fixing bolts and remove the CKPS (REF).
3. Visually check the CKPS (REF) for chipping.
SEF585P
OK or NG
OK
©
GO TO 15.
NG
©
Replace crankshaft position sensor (REF).
15
CHECK CRANKSHAFT POSITION SENSOR (REF)-II
Check resistance between CKPS (REF) terminals 1 and 2.
SEF350X
OK or NG
OK
©
GO TO 16.
NG
©
Replace crankshaft position sensor (REF).
DTC P1130 SWIRL CONTROL VALVE CONTROL SOLENOID VALVE
Diagnostic Procedure (Cont’d)
EC-468
16
CHECK INTERMITTENT INCIDENT
Perform “TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT”, EC-144.
©
INSPECTION END
PROCEDURE C
NHEC0530S03
1
INSPECTION START
Do you have CONSULT-II?
Yes or No
Yes
©
GO TO 2.
No
©
GO TO 3.
2
CHECK SWIRL CONTROL VALVE CONTROL SOLENOID VALVE CIRCUIT
With CONSULT-II
1. Turn ignition switch “OFF”.
2. Select “SWIRL CONT SOL/V” in “ACTIVE TEST” mode with CONSULT-II.
3. Touch “ON” and “OFF” on CONSULT-II screen.
SEC012C
4. Make sure that clicking sound is heard from the swirl control valve control solenoid valve.
OK or NG
OK
©
GO TO 6.
NG
©
GO TO 3.
GI
MA
EM
LC
FE
AT
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P1130 SWIRL CONTROL VALVE CONTROL SOLENOID VALVE
Diagnostic Procedure (Cont’d)
EC-469
3
CHECK SWIRL CONTROL VALVE CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
1. Turn ignition switch “OFF”.
2. Disconnect swirl control valve control solenoid valve harness connector.
SEF272X
3. Turn ignition switch “ON”.
4. Check voltage between swirl control valve control solenoid valve terminal 1 and ground with CONSULT-II or tester.
SEF619X
OK or NG
OK
©
GO TO 5.
NG
©
GO TO 4.
4
DETECT MALFUNCTIONING PART
Check the following.
I
Harness connectors M46, F44
I
15A fuse
I
Harness for open or short between swirl control valve control solenoid valve and fuse
©
Repair harness or connectors.
5
CHECK SWIRL CONTROL VALVE CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN
AND SHORT
1. Turn ignition switch “OFF”.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 29 and terminal 2. Refer to Wiring Diagram.
Continuity should exist.
4. Also, check harness for short to ground and short to power.
OK or NG
OK
©
GO TO 6.
NG
©
Repair open circuit, short to ground or short to power in harness connectors.
DTC P1130 SWIRL CONTROL VALVE CONTROL SOLENOID VALVE
Diagnostic Procedure (Cont’d)
EC-470