Infiniti I30 (A33). Manual — part 431
3
CHECK POWER SUPPLY CIRCUIT FOR INDICATOR LAMP
1. Disconnect security lamp connector.
2. Check voltage between indicator lamp terminal 1 and ground.
SEL653W
OK or NG
OK
©
Check harness for open or short between security indicator lamp and smart entrance
control unit.
NG
©
Check the following.
I
10A fuse [No. 12, located in fuse block (J/B)]
I
Harness for open or short between security indicator lamp and fuse
GI
MA
EM
LC
EC
FE
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
VEHICLE SECURITY (THEFT WARNING) SYSTEM
Trouble Diagnoses (Cont’d)
EL-393
DOOR KEY CYLINDER SWITCH CHECK
=NHEL0123S07
1
CHECK DOOR KEY CYLINDER SWITCH INPUT SIGNAL (LOCK/UNLOCK SIGNAL)
With CONSULT-II
Check front door key cylinder switch (“KEY CYL LK-SW”/“KEY CYL UN-SW”) in “DATA MONITOR” mode with CONSULT-
II.
SEL342W
Without CONSULT-II
Check voltage between smart entrance control unit harness connector M143 terminal 10 (OR/L) or 11 (OR/B) and ground.
SEL038Y
Refer to wiring diagram in EL-376.
OK or NG
OK
©
Door key cylinder switch is OK.
NG
©
GO TO 2.
2
CHECK DOOR KEY CYLINDER SWITCH
1. Disconnect door key cylinder switch connector.
2. Check continuity between door key cylinder switch connector terminals.
SEL650W
OK or NG
OK
©
Check the following.
I
Door key cylinder switch ground circuit
I
Harness for open or short between smart entrance control unit and door key cylinder
switch
NG
©
Replace door key cylinder switch.
VEHICLE SECURITY (THEFT WARNING) SYSTEM
Trouble Diagnoses (Cont’d)
EL-394
TRUNK LID KEY CYLINDER SWITCH CHECK
=NHEL0123S08
1
CHECK TRUNK LID KEY CYLINDER SWITCH INPUT SIGNAL (UNLOCK SIGNAL)
With CONSULT-II
Check trunk lid key cylinder switch (“TRUNK KEY SW”) in “DATA MONITOR” mode with CONSULT-II.
SEL358W
Without CONSULT-II
Check voltage between smart entrance control unit harness connector M143 terminal 12 (G/B) and ground.
SEL039Y
Refer to wiring diagram in EL-376.
OK or NG
OK
©
Trunk lid key cylinder switch is OK.
NG
©
GO TO 2.
2
CHECK TRUNK LID KEY CYLINDER SWITCH
1. Disconnect trunk lid key cylinder switch connector.
2. Check continuity between trunk lid key cylinder switch terminals.
SEL248W
OK or NG
OK
©
Check the following.
I
Trunk lid key cylinder switch ground circuit
I
Harness for open or short between smart entrance control unit and trunk lid key cylin-
der switch
NG
©
Replace trunk lid key cylinder switch.
GI
MA
EM
LC
EC
FE
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
VEHICLE SECURITY (THEFT WARNING) SYSTEM
Trouble Diagnoses (Cont’d)
EL-395
DOOR LOCK/UNLOCK SWITCH CHECK
NHEL0123S13
1
CHECK DOOR LOCK/UNLOCK SWITCH INPUT SIGNAL
With CONSULT-II
Check door lock/unlock switch (“LOCK SW DR/AS”/“UNLK SW DR/AS”) in “DATA MONITOR” mode with CONSULT-II.
SEL341W
Without CONSULT-II
1. Disconnect smart entrance control unit harness connector .
2. Check continuity between smart entrance control unit harness connector M143 terminal 4 (BR/Y) or 5 (GY) and ground.
SEL040Y
Refer to wiring diagram in EL-374.
OK or NG
OK
©
Door lock/unlock switch is OK.
NG
©
GO TO 2.
VEHICLE SECURITY (THEFT WARNING) SYSTEM
Trouble Diagnoses (Cont’d)
EL-396