Infiniti I30 (A33). Manual — part 422
HORN REMINDER CHECK
=NHEL0195S09
1
CHECK HORN
Check if horn sounds with horn switch.
Does horn operate?
Yes
©
GO TO 2.
No
©
Check horn circuit.
2
CHECK HORN REMINDER OPERATION WITH CONSULT-II
With CONSULT-II
1. Select “ACTIVE TEST” in “MULTI REMOTE ENT” with CONSULT-II.
2. Select “MULTI REM HRN” and touch “ON”.
SEL348W
NOTE: If CONSULT-II is not available, skip this procedure and go to the next step.
OK or NG
OK
©
Horn reminder operation is OK.
NG
©
GO TO 4.
3
CHECK HORN REMINDER OPERATION WITHOUT CONSULT-II
Without CONSULT-II
1. Disconnect smart entrance control unit harness connector.
2. Apply ground to smart entrance control unit harness connector M144 terminal 42 (BR/Y).
SEL028Y
Refer to wiring diagram in EL-343.
Does horn sound?
Yes
©
Replace smart entrance control unit.
No
©
GO TO 4.
GI
MA
EM
LC
EC
FE
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont’d)
EL-357
4
CHECK VEHICLE SECURITY HORN RELAY-2
Check vehicle security horn relay-2.
OK or NG
OK
©
GO TO 5.
NG
©
Replace vehicle security horn relay-2.
5
CHECK POWER SUPPLY FOR VEHICLE SECURITY HORN RELAY-2
1. Disconnect vehicle security horn relay-2 harness connector.
2. Check voltage between vehicle security horn relay-2 harness connector E63 terminal 1 (G/R) and ground.
SEL031Y
Does battery voltage exist?
Yes
©
GO TO 6.
No
©
Check the following.
I
15A fuse [No. 61, located in fuse block (J/B)]
I
Harness for open or short between vehicle security horn relay-2 and fuse
6
CHECK VEHICLE SECURITY HORN RELAY-2
1. Disconnect vehicle security horn relay-2 harness connector.
2. Check voltage between vehicle security horn relay-2 harness connector E63 terminals 5 (G) and 3 (B).
SEL032Y
OK or NG
OK
©
Check harness for open or short between smart entrance control unit and vehicle secu-
rity horn relay-2.
NG
©
Check the following.
I
Harness for open or short between vehicle security horn relay-2 and fuse
I
Harness for open or short between vehicle security horn relay-2 and body grounds
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont’d)
EL-358
INTERIOR LAMP OPERATION CHECK
=NHEL0195S10
1
CHECK INTERIOR LAMP
Check if the interior lamp switch is in the “ON” position and the lamp illuminates.
Does interior lamp illuminate?
Yes
©
GO TO 2.
No
©
Check the following.
I
Harness for open or short between smart entrance control unit and interior lamp
I
Interior lamp
2
CHECK INTERIOR LAMP OPERATION
With CONSULT-II
1. Select “ACTIVE TEST” in “MULTI REMOTE ENT” with CONSULT-II.
2. Select “INT/IGN ILLUM” and touch “ON”.
SEL349W
Without CONSULT-II
Push unlock button of remote controller with all doors closed and driver’s door locked, and check voltage between smart
entrance control unit harness connector M144 terminal 31 (R/Y) and ground.
SEL029Y
Refer to wiring diagram in EL-341.
OK or NG
OK
©
System is OK.
NG
©
Check harness open or short between smart entrance control unit and interior lamp.
GI
MA
EM
LC
EC
FE
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont’d)
EL-359
KEY HOLE ILLUMINATION OPERATION CHECK
NHEL0195S13
1
CHECK KEY HOLE ILLUMINATION OPERATION
With CONSULT-II
1. Select “ACTIVE TEST” IN “MULTI REMOTE ENT” with CONSULT-II.
2. Select “INT/IGN ILLUM” and touch “ON”.
SEL350W
Without CONSULT-II
Push unlock button of remote controller with all doors closed and driver’s door locked, and check voltage between smart
entrance control unit harness connector M144 terminal 30 (R/Y) and ground.
SEL030Y
Refer to wiring diagram in EL-341.
OK or NG
OK
©
System is OK.
NG
©
Check the following.
I
Harness for open or short between smart entrance control unit and key hole illumina-
tion.
I
Key hole illumination
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont’d)
EL-360