Infiniti QX56 (JA60). Manual — part 189
CHG
CHARGING SYSTEM
CHG-19
< COMPONENT DIAGNOSIS >
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
ABMIA1169GB
CHG-20
< SYMPTOM DIAGNOSIS >
CHARGING SYSTEM
SYMPTOM DIAGNOSIS
CHARGING SYSTEM
Symptom Table
INFOID:0000000005146566
Symptom
Reference
Battery discharged
Refer to
.
The charge warning lamp does not illuminate when the ignition
switch is set to ON.
The charge warning lamp does not turn OFF after the engine
starts.
The charging warning lamp turns ON when increasing the engine
speed.
CHG
GENERATOR
CHG-21
< ON-VEHICLE REPAIR >
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
ON-VEHICLE REPAIR
GENERATOR
Removal and Installation
INFOID:0000000005146567
REMOVAL
1. Disconnect the negative battery terminal. Refer to
PG-74, "Removal and Installation"
2. Remove the fan shroud. Refer to
CO-15, "Removal and Installation"
3. Remove the drive belt. Refer to
EM-13, "Removal and Installation"
.
4. Remove lower bracket, using power tools.
5. Remove the generator upper bolt, using power tools.
6. Disconnect the generator harness connectors.
7. Remove the generator.
INSTALLATION
Installation is in the reverse order of removal.
• Install the generator and check the tension of the drive belt. Refer to
CAUTION:
Tighten terminal nut carefully.
WKIA1390E
Terminal nut
: 10.8 N·m (1.1 kg-m, 8 ft-lb)
CHG-22
< SERVICE DATA AND SPECIFICATIONS (SDS)
GENERATOR
SERVICE DATA AND SPECIFICATIONS (SDS)
GENERATOR
Generator
INFOID:0000000005146568
Model
TG15S147
Manufacturer
Valeo
Nominal rating
14V-130A
Ground polarity
Negative
Minimum revolution under no-load
1,200 rpm
Hot output current (When 13.5 volts is applied)
More than 52A/1,500 rpm
More than 82A/1,800 rpm
More than 115A/2,500 rpm
More than 130A/5,000 rpm
Regulated output voltage
13.5V @ 5,000 rpm @ 20
°C
Adjustment range of power generation variable voltage control
11.4-15.6V