Infiniti QX56 (JA60). Manual — part 598
BLOWER MOTOR CONTROL SYSTEM
HAC-49
< COMPONENT DIAGNOSIS >
[AUTOMATIC AIR CONDITIONER]
C
D
E
F
G
H
J
K
L
M
A
B
HAC
N
O
P
SYMPTOM: Blower motor operation is malfunctioning under starting
blower speed control.
1.
CHECK FUSES
Check 20A fuses [No. 24 and 27 (Located in the fuse and fusible link box)]. For fuse layout. Refer to
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> GO TO 7.
2.
CHECK FRONT BLOWER MOTOR POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect front blower motor connector.
3. Turn ignition switch ON.
4. Press the A/C switch.
5. Press the front blower control "+" switch to maximum speed.
6. Check voltage between front blower motor harness connector
M62 terminal 2 and ground.
Is the inspection result normal?
YES
>> GO TO 10.
NO
>> GO TO 3.
3.
CHECK FRONT BLOWER MOTOR RELAY (SWITCH SIDE) POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect front blower motor relay.
3. Turn ignition switch ON.
4. Check voltage between front blower motor relay harness con-
nector M107 terminal 5 and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair harness or connector.
AWIIA0174GB
Fuses are good.
2 - Ground
: Battery voltage
WJIA1331E
5 - Ground
: Battery voltage
WJIA1359E
HAC-50
< COMPONENT DIAGNOSIS >
[AUTOMATIC AIR CONDITIONER]
BLOWER MOTOR CONTROL SYSTEM
4.
CHECK FRONT BLOWER MOTOR RELAY
Turn ignition switch OFF.
Check front blower motor relay. Refer to
HAC-52, "Front Blower Motor Component Inspection"
.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace front blower motor relay.
5.
CHECK FRONT BLOWER MOTOR RELAY (SWITCH SIDE) CIRCUIT FOR OPEN
Check continuity between front blower motor relay harness connec-
tor M107 terminal 3 and front blower motor harness connector M62
terminal 2.
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> Repair harness or connector.
6.
CHECK FRONT BLOWER MOTOR RELAY (COIL SIDE) POWER SUPPLY
1. Turn ignition switch ON.
2. Check voltage between front blower motor relay harness con-
nector M107 terminal 2 and ground.
Is the inspection result normal?
YES
>> Repair front blower motor ground circuit or connector.
NO
>> Repair harness or connector.
7.
REPLACE FUSES
Replace fuses.
Does the fuse blow?
YES
>> • If fuse blows without activating the front blower motor, repair short between fuse and front
blower motor relay.
• If fuse blows activating the front blower motor, GO TO 8.
NO
>> Inspection End.
8.
CHECK FRONT BLOWER MOTOR POWER SUPPLY CIRCUIT FOR SHORT
1. Turn ignition switch OFF.
2. Disconnect front blower motor connector, front blower motor
relay and variable blower control connector.
3. Check continuity between variable blower control harness con-
nector M122 terminal 4 and ground.
Is the inspection result normal?
YES
>> GO TO 9.
NO
>> Repair harness or connector.
9.
CHECK FRONT BLOWER MOTOR
Check front blower motor. Refer to
HAC-52, "Front Blower Motor Component Inspection"
.
Is the inspection result normal?
3 - 2
: Continuity should exist.
WJIA1360E
2 - Ground
: Battery voltage
WJIA1363E
4 - Ground
: Continuity should not exist.
AWIIA0177ZZ
BLOWER MOTOR CONTROL SYSTEM
HAC-51
< COMPONENT DIAGNOSIS >
[AUTOMATIC AIR CONDITIONER]
C
D
E
F
G
H
J
K
L
M
A
B
HAC
N
O
P
YES
>> Replace variable blower control (front). Refer to
VTL-15, "Removal and Installation"
NO
>> Replace front blower motor. Refer to
VTL-12, "Removal and Installation"
10.
CHECK FRONT BLOWER MOTOR
Check front blower motor. Refer to
HAC-52, "Front Blower Motor Component Inspection"
.
Is the inspection result normal?
YES
>> GO TO 11.
NO
>> Replace front blower motor. Refer to
VTL-12, "Removal and Installation"
11.
CHECK BLOWER MOTOR GROUND CIRCUIT
1. Disconnect variable blower control connector.
2. Check continuity between front blower motor harness connector
M62 (B) terminal 1 and variable blower control harness connec-
tor M122 (A) terminal 2.
Is the inspection result normal?
YES
>> GO TO 12.
NO
>> Repair harness or connector.
12.
CHECK VARIABLE BLOWER CONTROL POWER SUPPLY CIRCUIT FOR OPEN
1. Disconnect front blower motor relay.
2. Check continuity between front blower motor relay harness con-
nector M107 (A) terminals 3 and variable blower control harness
connector M122 (B) terminal 4.
Is the inspection result normal?
YES
>> GO TO 13.
NO
>> Repair harness or connector.
13.
CHECK VARIABLE BLOWER CONTROL GROUND CIRCUIT
Check continuity between variable blower control harness connector
M122 terminal 1 and ground.
Is the inspection result normal?
YES
>> GO TO 14.
NO
>> Repair harness or connector.
14.
CHECK VARIABLE BLOWER CONTROL SIGNAL CIRCUIT
1 - 2
: Continuity should exist.
AWIIA0179ZZ
3 - 4
: Continuity should exist.
AWIIA0175ZZ
1 - Ground
: Continuity should exist.
AWIIA0180ZZ
HAC-52
< COMPONENT DIAGNOSIS >
[AUTOMATIC AIR CONDITIONER]
BLOWER MOTOR CONTROL SYSTEM
1. Reconnect all disconnected component connectors.
2. Disconnect A/C auto amp. connector.
3. Turn ignition switch ON.
4. Press the blower (+) switch to maximum speed.
5. Check voltage between A/C auto amp. harness connector M49
terminal 13 and ground.
Is the inspection result normal?
YES
>> Replace A/C auto amp. Refer to
NO
>> GO TO 15.
15.
CHECK VARIABLE BLOWER CONTROL SIGNAL CIRCUIT FOR OPEN
1. Disconnect variable blower control connector.
2. Check continuity between A/C auto amp. harness connector
M49 (B) terminal 13 and variable blower control harness con-
nector M122 (A) terminal 3.
Is the inspection result normal?
YES
>> Replace variable blower control. Refer to
.
NO
>> Repair harness or connector.
Front Blower Motor Component Inspection
INFOID:0000000005147703
COMPONENT INSPECTION
Check continuity between terminals by supplying 12 volts and
ground to coil side terminals of relay.
Front Blower Motor
13 - Ground
: Approx. 4.5V
AWIIA1129ZZ
13 - 3
: Continuity should exist.
AWIIA0178ZZ
WJIA1401E