Infiniti G35 (V35). Manual — part 391
DTC P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR
EC-445
C
D
E
F
G
H
I
J
K
L
M
A
EC
Wiring Diagram
NBS000TI
TBWM0815E
EC-446
DTC P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic Procedure
NBS000TJ
1.
CHECK GROUND CONNECTIONS
1.
Turn ignition switch OFF.
2.
Loosen and retighten two ground screws on the body. Refer to
OK or NG
OK
>> GO TO 2.
NG
>> Repair or replace ground connections.
2.
CHECK CONNECTOR
1.
Disconnect EVAP control system pressure sensor harness connector.
2.
Check sensor harness connector for water.
OK or NG
OK
>> GO TO 3.
NG
>> Repair or replace harness connector.
TER-
MINAL
NO.
WIRE
COLOR
ITEM
CONDITION
DATA (DC Voltage)
32
P
EVAP control system pres-
sure sensor
[Ignition switch: ON]
Approximately 1.8 - 4.8V
48
B/Y
Sensor power supply
(EVAP control system pres-
sure sensor)
[Ignition switch: ON]
Approximately 5V
67
B/W
Sensor ground
[Engine is running]
●
Warm-up condition
●
Idle speed
Approximately 0V
PBIB2192E
Water should not exist.
PBIB1086E
DTC P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR
EC-447
C
D
E
F
G
H
I
J
K
L
M
A
EC
3.
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT
1.
Turn ignition switch ON.
2.
Check voltage between EVAP control system pressure sensor
terminal 3 and ground with CONSULT-II or tester.
OK or NG
OK
>> GO TO 5.
NG
>> GO TO 4.
4.
DETECT MALFUNCTIONING PART
Check the following.
●
Harness connectors B1, M12
●
Harness connectors M72, F102
●
Harness for open or short between EVAP control system pressure sensor and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
5.
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND
SHORT
1.
Turn ignition switch OFF.
2.
Disconnect ECM harness connector.
3.
Check harness continuity between EVAP control system pressure sensor terminal 1 and ECM terminal
67.
Refer to Wiring Diagram.
4.
Also check harness for short to ground and short to power.
OK or NG
OK
>> GO TO 7.
NG
>> GO TO 6.
6.
DETECT MALFUNCTIONING PART
Check the following.
●
Harness connectors B1, M12
●
Harness connectors M72, F102
●
Harness for open or short between EVAP control system pressure sensor and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
Voltage: Approximately 5V
PBIB0138E
Continuity should exist.
EC-448
DTC P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR
7.
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND
SHORT
1.
Check harness continuity between ECM terminal 32 and EVAP control system pressure sensor terminal
2.
Refer to Wiring Diagram.
2.
Also check harness for short to ground and short to power.
OK or NG
OK
>> GO TO 9.
NG
>> GO TO 8.
8.
DETECT MALFUNCTIONING PART
Check the following.
●
Harness connectors B1, M12
●
Harness connectors M72, F102
●
Harness for open or short between EVAP control system pressure sensor and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
9.
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Refer to
EC-448, "Component Inspection"
OK or NG
OK
>> GO TO 10.
NG
>> Replace EVAP control system pressure sensor.
10.
CHECK INTERMITTENT INCIDENT
Refer to
EC-151, "TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT"
.
>> INSPECTION END
Component Inspection
NBS000TK
EVAP CONTROL SYSTEM PRESSURE SENSOR
1.
Remove EVAP control system pressure sensor with its harness connector connected from EVAP canister.
Always replace O-ring with a new one.
2.
Install a vacuum pump to EVAP control system pressure sensor.
3.
Turn ignition switch ON and check output voltage between ECM
terminal 32 and ground under the following conditions.
CAUTION:
●
Always calibrate the vacuum pump gauge when using it.
●
Do not apply below -93.3 kPa (-700 mmHg, -27.56 inHg) or
pressure over 101.3 kPa (760 mmHg, 29.92 inHg).
4.
If NG, replace EVAP control system pressure sensor.
Continuity should exist.
Applied vacuum kPa
(mmHg, inHg)
Voltage V
Not applied
1.8 - 4.8
-26.7 (-200, -7.87)
2.1 to 2.5V lower than above value