Infiniti G35 (V35). Manual — part 198
TRUNK LID OPENER
BL-179
C
D
E
F
G
H
J
K
L
M
A
B
BL
7.
CHECK TRUNK LID OPENER SWITCH
1.
Disconnect trunk lid opener switch connector.
2.
Check continuity between trunk lid opener switch connector M84 terminals 1 and 2.
OK or NG
OK
>> GO TO 8.
NG
>> Replace trunk lid opener switch.
8.
CHECK TRUNK LID OPENER CANCEL SWITCH CIRCUIT
1.
Disconnect BCM connector.
2.
Turn on trunk lid opener switch.
3.
Check continuity between BCM connector M1 terminal 30 and
trunk lid opener cancel switch connector M56 terminal 1.
4.
Check continuity between BCM connector M1 terminal 30 and
ground.
OK or NG
OK
>> GO TO 9.
NG
>> Repair harness or connector.
9.
CHECK TRUNK LID OPENER SWITCH CIRCUIT
1.
Check continuity between trunk lid opener cancel switch con-
nector M56 terminal 2 and trunk lid opener switch connector
M84 terminal 1.
2.
Check continuity between trunk lid opener cancel switch con-
nector M56 terminal 2 and ground.
OK or NG
OK
>> GO TO 10.
NG
>> Repair harness or connector.
Terminals
Trunk lid opener switch
condition
Continuity
1
2
ON (Pushed)
Yes
OFF (Released)
No
PIIB9160E
30 (P) - 1 (P)
: Continuity should exist.
30 (P) - Ground
: Continuity should not exist.
PIIB7642E
Trunk lid opener cancel switch
(A)
Trunk lid opener switch (B)
Continuity
Connector
Terminal
Connector
Terminal
M56
2
M84
1
Yes
Trunk lid opener cancel switch (A)
Ground
Continuity
Connector
Terminal
M56
2
No
PIIB9161E
BL-180
TRUNK LID OPENER
10.
CHECK TRUNK LID OPENER SWITCH GROUND CIRCUIT
Check continuity between trunk lid opener switch connector M84 ter-
minal 2 and ground.
OK or NG
OK
>> Check condition of harness and connector.
NG
>> Repair or replace harness.
TRUNK DOES NOT OPEN WITH REAR COMBINATION LAMP LH (OUTSIDE TRUNK LID
OPENER SWITCH) / WITHOUT INTELLIGENT KEY
1.
CHECK TRUNK LID OPENER CANCEL SWITCH
Check trunk lid opener cancel switch position.
Does trunk lid opener cancel switch turn OFF (CANCEL)?
Yes
>> Turn on trunk lid opener cancel switch.
No
>> GO TO 2.
2.
CHECK TRUNK LID OPEN INPUT SIGNAL
With CONSULT-II
Check trunk lid opener switch (“TRNK OPNR SW”) in “DATA MONI-
TOR” mode with CONSULT-II.
●
When trunk lid opener switch is turned to “LOCK”.
Without CONSULT-II
1.
Remove key from ignition key cylinder.
2.
Turn on trunk lid opener cancel switch.
3.
Check voltage between BCM connector and ground.
OK or NG
OK
>> GO TO 3.
NG
>> GO TO 6.
Trunk lid opener switch (A)
Ground
Continuity
Connector
Terminal
M84
2
Yes
PIIB9162E
TRNK OPNR SW
: ON
PIIA9937E
Connector
Terminal
(Wire color)
Condition
Voltage [V]
(Approx.)
(+)
(–)
M1
30 (P)
Ground
Trunk lid opener switch ON
0
Trunk lid opener switch OFF
5
PIIA9334E
TRUNK LID OPENER
BL-181
C
D
E
F
G
H
J
K
L
M
A
B
BL
3.
CHECK TRUNK LID OPEN OUTPUT SIGNAL
Check voltage between BCM connector and ground.
OK or NG
OK
>> GO TO 4.
NG
>> Replace BCM. Refer to
BCS-16, "Removal and Installa-
4.
CHECK TRUNK LID LOCK ASSEMBLY (TRUNK LID OPENER ACTUATOR) CIRCUIT
1.
Disconnect BCM connector and trunk lid lock assembly (trunk lid opener actuator) connector.
2.
Check continuity between BCM harness connector B4 terminal
68 and trunk lid lock assembly (trunk lid opener actuator) har-
ness connector B419 terminal 2.
3.
Check continuity between BCM harness connector B4 terminal
68 and ground.
OK or NG
OK
>> GO TO 5.
NG
>> Repair harness or connector.
5.
CHECK TRUNK LID LOCK ASSEMBLY (TRUNK LID OPENER ACTUATOR) GROUND CIRCUIT
Check continuity between trunk lid lock assembly (trunk lid opener
actuator) connector B419 terminal 1 and ground.
OK or NG
OK
>> Replace trunk lid lock assembly (trunk lid opener actua-
tor).
NG
>> Repair harness or connector.
Connector
Terminal
(Wire color)
Condition
Voltage [V]
(Approx.)
(+)
(–)
B4
68 (G/W)
Ground
Trunk lid opener switch
ON
Battery voltage
Trunk lid opener switch
OFF
0
PIIB9157E
BCM (A)
Trunk lid lock assembly (trunk lid
opener actuator) (B)
Continuity
Connector
Terminal
Connector
Terminal
B4
68
B419
2
Yes
BCM (A)
Ground
Continuity
Connector
Terminal
B4
68
No
PIIB9158E
Trunk lid lock assembly (trunk lid
opener actuator) (A)
Ground
Continuity
Connector
Terminal
B419
1
Yes
PIIB9159E
BL-182
TRUNK LID OPENER
6.
CHECK TRUNK LID OPENER CANCEL SWITCH
1.
Turn ignition switch OFF.
2.
Disconnect trunk lid opener cancel switch connector.
3.
Check continuity between trunk lid opener cancel switch connector M56 terminals 1 and 2.
OK or NG
OK
>> GO TO 7.
NG
>> Replace trunk lid opener cancel switch.
7.
CHECK PASSENGER SIDE DOOR LOCK ASSEMBLY (DOOR UNLOCK SENSOR)
1.
Disconnect passenger side door lock assembly (door unlock sensor) connector.
2.
Check continuity between passenger side door lock assembly (door unlock sensor) connector D44 termi-
nals 2 and 3.
OK or NG
OK
>> GO TO 8.
NG
>> Replace passenger side door lock assembly (door
unlock sensor).
8.
CHECK TRUNK LID OPENER CANCEL SWITCH CIRCUIT
1.
Disconnect BCM connector.
2.
Check continuity between BCM connector M1 terminal 30 and
trunk lid opener cancel switch connector M56 terminal 1.
3.
Check continuity between BCM connector M1 terminal 30 and
ground.
OK or NG
OK
>> GO TO 9.
NG
>> Repair harness or connector.
Terminals
Trunk lid opener cancel
switch condition
Continuity
1
2
ON
Yes
OFF
No
PIIA7871E
Terminals
Passenger side door lock assem-
bly (door unlock sensor) condition
Continuity
2
3
UNLOCKED (ON)
Yes
LOCKED (OFF)
No
PIIB7418E
30 (P) - 1 (P)
: Continuity should exist.
30 (P) - Ground
: Continuity should not exist.
PIIB7642E