Infiniti G35 (V35). Manual — part 96
TROUBLE DIAGNOSIS
ATC-55
C
D
E
F
G
H
I
K
L
M
A
B
ATC
10.
CHECK AMBIENT SENSOR
Press
(DEF) switch one time. Temperature detected by ambient
sensor is indicated on the display.
NOTE:
If the temperature indicated on the display greatly differs from the
actual temperature, check sensor circuit first, and then check sensor.
OK or NG
OK
>> GO TO 11.
NG
>> Go to Ambient Sensor Circuit. Refer to
11.
CHECK IN-VEHICLE SENSOR
Press
(DEF) switch for the second time. Temperature detected
by in-vehicle sensor is indicated on the display.
NOTE:
If the temperature indicated on the display greatly differs from the
actual temperature, check sensor circuit first, and then check sensor.
OK or NG
OK
>> GO TO 12.
NG
>> Go to In-vehicle Sensor Circuit. Refer to
12.
CHECK INTAKE SENSOR
Press
(DEF) switch for the third time. Temperature detected by
intake sensor is indicated on the display.
NOTE:
If the temperature indicated on the display greatly differs from the
actual temperature, check sensor circuit first, and then check sensor.
OK or NG
OK
>> GO TO 13.
NG
>> Go to Intake Sensor Circuit. Refer to
13.
CHECK MULTIPLEX COMMUNICATION ERROR
1.
Press recirculation
(REC) switch.
2.
Multiplex communication error between display and A/C auto
amp. and A/C and audio controller can be detected as self-diag-
nosis results.
(If plural errors occur, the display of each error will blink twice for
0.5 second intervals.)
Is multiplex communication error detected as self-diagnosis results?
YES
>> Go to multiplex communication circuit. Refer to
111, "Multiplex Communication Circuit"
.
NO
>> 1. Turn ignition switch OFF or AUTO. ECON switch ON.
2. INSPECTION END
RHA499G
RHA500G
RHA500GB
RJIA3485E
ATC-56
TROUBLE DIAGNOSIS
14.
CHECK MALFUNCTIONING SENSOR AND DOOR MOTOR
Refer to the following chart for malfunctioning code No.
(If two or more sensors malfunction, corresponding code Nos. blink respectively twice.)
(If two door motors malfunction, corresponding code Nos. blink respectively once.)
*1: Perform self-diagnosis STEP-2 under sunshine.
When performing indoors, aim a light (more than 60 W) at sunload sensor, otherwise code No.25 will indicate
despite that sunload sensor is functioning properly.
*2:
ATC-101, "DIAGNOSIS PROCEDURE FOR AMBIENT SENSOR"
*3:
ATC-104, "DIAGNOSIS PROCEDURE FOR IN-VEHICLE SENSOR"
.
*4:
ATC-109, "DIAGNOSIS PROCEDURE FOR INTAKE SENSOR"
*5:
ATC-106, "DIAGNOSIS PROCEDURE FOR SUNLOAD SENSOR"
*6:
ATC-73, "DIAGNOSIS PROCEDURE FOR AIR MIX DOOR MOTOR PBR"
>> INSPECTION END
Code No.
Malfunctioning sensor and door motor (Including circuits)
Reference page
21 /
−
21
Ambient sensor
*2
22 /
−
22
In-vehicle sensor
*3
24 /
−
24
Intake sensor
*4
25 /
−
25
Sunload sensor
*1
*5
26 /
−
26
With DUAL switch
Air mix door motor PBR (Driver side)
*6
Without DUAL switch
Air mix door motor PBR (Passenger side)
27 /
−
27
With DUAL switch only
Air mix door motor PBR (Passenger side)
PJIA0162E
TROUBLE DIAGNOSIS
ATC-57
C
D
E
F
G
H
I
K
L
M
A
B
ATC
15.
CHECK MALFUNCTIONING DOOR MOTOR POSITION SWITCH
Mode and/or intake door motor PBR(s) is/are malfunctioning.
(If two or more mode or intake door motors malfunction, corresponding code Nos. blink respectively twice.)
*1: If mode door motor harness connector is disconnected, the following display pattern will appear.
31
→
32
→
33
→
34
→
35
→
36
→
Return to 31
*2: If intake door motor harness connector is disconnected, the following display pattern will appear.
37
→
38
→
39
→
Return to 37
*3: FOOT position during automatic control. Refer to
ATC-59, "AUXILIARY MECHANISM: FOOT POSITION
*4:
ATC-70, "DIAGNOSIS PROCEDURE FOR MODE DOOR MOTOR"
.
*5:
ATC-76, "DIAGNOSIS PROCEDURE FOR INTAKE DOOR MOTOR"
.
>> INSPECTION END
Code No.
*1 *2
Mode or intake door position
Reference page
31
VENT
Mode door motor
*4
32
B/L 1
33
B/L 2
34
FOOT
*3
35
D/F
36
DEF
37
FRE
Intake door motor
*5
38
20% FRE
39
REC
PJIA0163E
ATC-58
TROUBLE DIAGNOSIS
AUXILIARY MECHANISM: TEMPERATURE SETTING TRIMMER
The trimmer compensates for differences in range of
±
3
°
C (
±
6
°
F) between temperature setting (displayed dig-
itally) and temperature felt by customer.
Operating procedures for this trimmer are as follows:
1.
Begin self-diagnosis STEP-5 mode. Refer to
ATC-51, "Self-diagnosis Function"
2.
Press (fan) UP switch to set system in auxiliary mode.
3.
Display shows “61” in auxiliary mechanism. It takes approximately 3 seconds to enable setting operation.
4.
Turn temperature control dial as desired. Temperature will change at a rate of 0.5
°
C (1.0
°
F) each time a
dial is turned.
When battery cable is disconnected or battery voltage is below 10 V, trimmer operation is canceled. Tempera-
ture set becomes that of initial condition, i.e. 0
°
C (0
°
F).
RJIA3486E