Infiniti G35 (V35). Manual — part 359
DTC P0139, P0159 HO2S2
EC-317
C
D
E
F
G
H
I
J
K
L
M
A
EC
2.
CLEAR THE SELF-LEARNING DATA
With CONSULT-II
1.
Start engine and warm it up to normal operating temperature.
2.
Select “SELF-LEARNING CONT” in “WORK SUPPORT” mode
with CONSULT-II.
3.
Clear the self-learning control coefficient by touching “CLEAR”.
4.
Run engine for at least 10 minutes at idle speed.
Is the 1st trip DTC P0171, P0172, P0174 or P0175 detected?
Is it difficult to start engine?
Without CONSULT-II
1.
Start engine and warm it up to normal operating temperature.
2.
Turn ignition switch OFF.
3.
Disconnect mass air flow sensor harness connector, and restart
and run engine for at least 5 seconds at idle speed.
4.
Stop engine and reconnect mass air flow sensor harness con-
nector.
5.
Make sure DTC P0102 is displayed.
6.
Erase the DTC memory. Refer to
EMISSION-RELATED DIAGNOSTIC INFORMATION"
.
7.
Make sure DTC P0000 is displayed.
8.
Run engine for at least 10 minutes at idle speed.
Is the 1st trip DTC P0171, P0172, P0174 or P0175 detected?
Is it difficult to start engine?
Yes or No
Yes
>> Perform trouble diagnosis for DTC P0171, P0174 or P0172, P0175. Refer to
P0171, P0174 FUEL INJECTION SYSTEM FUNCTION"
or
EC-333, "DTC P0172, P0175 FUEL
No
>> GO TO 3.
SEF968Y
PBIB1077E
EC-318
DTC P0139, P0159 HO2S2
3.
CHECK HO2S2 GROUND CIRCUIT FOR OPEN AND SHORT
1.
Turn ignition switch OFF.
2.
Disconnect ECM harness connector.
3.
Disconnect heated oxygen sensor 2 harness connector.
4.
Check harness continuity between HO2S2 terminal 1 and ECM terminal 78.
Refer to Wiring Diagram.
5.
Also check harness for short to ground and short to power.
OK or NG
OK
>> GO TO 4.
NG
>> Repair open circuit or short to ground or short to power in harness or connectors.
4.
CHECK HO2S2 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1.
Check harness continuity between ECM terminal and HO2S2 terminal as follows.
Refer to Wiring Diagram.
2.
Check harness continuity between the following terminals and ground.
Refer to Wiring Diagram.
3.
Also check harness for short to power.
OK or NG
OK
>> GO TO 5.
NG
>> Repair open circuit or short to ground or short to power in harness or connectors.
Continuity should exist.
PBIB1908E
DTC
Terminals
Bank
ECM
Sensor
P0139
74
4
1
P0159
55
4
2
Continuity should exist.
DTC
Terminals
Bank
ECM
Sensor
P0139
74
4
1
P0159
55
4
2
Continuity should not exist.
DTC P0139, P0159 HO2S2
EC-319
C
D
E
F
G
H
I
J
K
L
M
A
EC
5.
CHECK HEATED OXYGEN SENSOR 2
Refer to
EC-319, "Component Inspection"
OK or NG
OK
>> GO TO 6.
NG
>> Replace malfunctioning heated oxygen sensor 2.
6.
CHECK INTERMITTENT INCIDENT
Refer to
EC-151, "TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT"
>> INSPECTION END
Component Inspection
NBS000QV
HEATED OXYGEN SENSOR 2
With CONSULT-II
1.
Turn ignition switch ON and select “DATA MONITOR” mode with
CONSULT-II.
2.
Start engine and warm it up to the normal operating tempera-
ture.
3.
Turn ignition switch OFF and wait at least 10 seconds.
4.
Start engine and keep the engine speed between 3,500 and
4,000 rpm for at least 1 minute under no load.
5.
Let engine idle for 1 minute.
6.
Select “FUEL INJECTION” in “ACTIVE TEST” mode, and select
“HO2S2 (B1)/(B2)” as the monitor item with CONSULT-II.
7.
Check “HO2S2 (B1)/(B2)” at idle speed when adjusting “FUEL INJECTION” to
±
25%.
“HO2S2 (B1)/(B2)” should be above 0.78V at least once when the “FUEL INJECTION” is +25%.
“HO2S2 (B1)/(B2)” should be below 0.18V at least once when the “FUEL INJECTION” is
−
25%.
CAUTION:
●
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7
in) onto a hard surface such as a concrete floor; use a new one.
SEF174Y
PBIB1672E
PBIB2163E
EC-320
DTC P0139, P0159 HO2S2
●
Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread
Cleaner tool J-43897-18 or J-43897-12 and approved anti-seize lubricant.
Without CONSULT-II
1.
Start engine and warm it up to the normal operating temperature.
2.
Turn ignition switch OFF and wait at least 10 seconds.
3.
Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1 minute under no load.
4.
Let engine idle for 1 minute.
5.
Set voltmeter probes between ECM terminal 74 [HO2S2 (B1) signal] or 55 [HO2S2 (B2) signal] and
ground.
6.
Check the voltage when revving up to 4,000 rpm under no load
at least 10 times.
(Depress and release accelerator pedal as soon as possible.)
The voltage should be above 0.78V at least once during this
procedure.
If the voltage is above 0.78V at step 6, step 7 is not neces-
sary.
7.
Keep vehicle at idling for 10 minutes, then check voltage. Or
check the voltage when coasting from 80 km/h (50 MPH) in D
position (A/T), 4th gear position (M/T).
The voltage should be below 0.18V at least once during this
procedure.
8.
If NG, replace heated oxygen sensor 2.
CAUTION:
●
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7
in) onto a hard surface such as a concrete floor; use a new one.
●
Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread
Cleaner tool J-43897-18 or J-43897-12 and approved anti-seize lubricant.
Removal and Installation
NBS000QW
HEATED OXYGEN SENSOR 2
Refer to
EM-25, "EXHAUST MANIFOLD AND THREE WAY CATALYST"
.
PBIB1607E