Infiniti G35 (V35). Manual — part 793
WT-18
TROUBLE DIAGNOSIS
46 (PU/W)
Turn signal (right)
●
Ignition switch ON
●
Combination switch is turn signal
(right) ON
52 (B)
Ground
—
0 V
55 (W/R)
Battery power supply (F/L)
Always
Battery voltage (12 V)
Terminal
(Wire color)
Item
Condition
Voltage (V)
Approx. value
SKIA3009J
TROUBLE DIAGNOSIS
WT-19
C
D
F
G
H
I
J
K
L
M
A
B
WT
ID Registration Procedure
NES000BV
ID REGISTRATION WITH ACTIVATION TOOL
This procedure must be done after replacement of a transmitter or BCM.
1.
Perform “CONSULT-II Start Procedure”. Refer to
GI-37, "CONSULT-II Start Procedure"
.
2.
Touch “WORK SUPPORT” on “SELECT DIAG MODE” screen, and select “ID REGIST”.
3.
With the activation tool (J-45295) pushed against the front-left
transmitter position of the tire air valve, press the button then
keep 5 seconds.
4.
Register the IDs in order from FR LH, FR RH, RR RH to RR LH.
When ID registration of each wheel has been completed, turn
signal lamp (LH/ RH) blinks.
5.
After completing all ID registrations, press “END” to complete the procedure.
NOTE:
Be sure to register the IDs in order from FR LH, FR RH, RR RH, to RR LH, or the self-diagnostic results dis-
play will not function properly.
ID REGISTRATION WITHOUT ACTIVATION TOOL
This procedure must be done after replacement of a transmitter or BCM.
1.
Perform “CONSULT-II Start Procedure”. Refer to
GI-37, "CONSULT-II Start Procedure"
.
2.
Touch “WORK SUPPORT” on “SELECT DIAG MODE” screen, and select “ID REGIST”.
3.
Adjust the tire pressure to the values shown in the table below for ID registration, and drive the vehicle at
40 km/h (25 MPH) or more for a few minutes.
4.
After completing all ID registrations, press “END” to complete the procedure.
5.
Inflate all tires to proper pressure. Refer to
WT-38, "SERVICE DATA AND SPECIFICATIONS (SDS)"
Activation tire position
Turn signal lamp
CONSULT-II
1
Front LH
2 times flashing
“YET”
↓
“DONE”
2
Front RH
3
Rear RH
4
Rear LH
SEIA0460E
Tire position
Tire pressure kPa (kg/cm
2
, psi)
Front
−
Left
240 (2.4, 34)
Front
−
Right
220 (2.2, 31)
Rear
−
Right
200 (2.0, 29)
Rear
−
Left
180 (1.8, 26)
Activation tire position
CONSULT-II
Front LH
“YET”
↓
“DONE”
Front RH
Rear RH
Rear LH
WT-20
TROUBLE DIAGNOSIS
Transmitter Wake Up Operation
NES000BW
WITH ACTIVATION TOOL
1.
With the activation tool (J-45295) pushed against the front-left
transmitter, press the button for 5 seconds.
●
When ignition switch ON, as the low tire pressure warning
lamp blinks per the follow diagram, the respective transmitter
then must be woken up.
2.
Register the ID of wheel that warning lamp flashes. When wake up of registered wheel has been com-
pleted, turn signal lamp flashes two times.
3.
After completing wake up of all transmitters, make sure low tire pressure warning lamp goes out.
CONSULT-II Function (BCM)
NES000BY
CONSULT-II MAIN FUNCTION
CONSULT-II can display each diagnostic item using the diagnostic test modes shown following.
CONSULT-II SETTING PROCEDURE
Perform “CONSULT-II Start Procedure”. Refer to
GI-37, "CONSULT-II Start Procedure"
WORK SUPPORT MODE
Operation Procedure
1.
Perform “CONSULT-II Start Procedure”. Refer to
GI-37, "CONSULT-II Start Procedure"
2.
Touch “WORK SUPPORT”.
SEIA0460E
SEIA0378E
BCM diagno-
sis part
Mode
Function
Reference
Air pressure
monitor
WORK SUPPORT
This mode enables a technician to adjust some devices faster and
more accurately by following the indications on CONSULT-II.
SELF-DIAG
RESULTS
Self-diagnostic results can be read and erased quickly.
WT-21, "SELF-DIAG
RESULTS MODE"
DATA MONITOR
Input/Output data in the control unit can be read.
ACTIVE TEST
Diagnostic Test Mode in with CONSULT-II drives some actuators apart
from the control unit (BCM) and also shifts some parameters in a spec-
ified range.
TROUBLE DIAGNOSIS
WT-21
C
D
F
G
H
I
J
K
L
M
A
B
WT
3.
Select from “SELECT WORK ITEM”, screen of work support
made is displayed
ID Read
The registered ID number is displayed.
ID Regist
Refer to
WT-19, "ID Registration Procedure"
SELF-DIAG RESULTS MODE
Operation Procedure
1.
Perform “CONSULT-II Start Procedure”. Refer to
GI-37, "CONSULT-II Start Procedure"
.
2.
Touch “SELF-DIAG RESULTS”. Display shows malfunction experienced since the last erasing operation.
SEIA0583E
SEIA0584E