Infiniti G35 (V35). Manual — part 106
TROUBLE DIAGNOSIS
ATC-95
C
D
E
F
G
H
I
K
L
M
A
B
ATC
Low-pressure Side Sometimes Becomes Negative
Low-pressure Side Becomes Negative
DIAGNOSIS PROCEDURE FOR INSUFFICIENT COOLING
SYMPTOM: Insufficient cooling
1.
CHECK POWER SUPPLY FOR ECV (ELECTRONIC CONTROL VALVE)
1.
Disconnect compressor (ECV) connector.
2.
Turn ignition switch ON.
3.
Check voltage between compressor (ECV) harness connector
F34 terminal 3 and ground.
OK or NG
OK
>> GO TO 2.
NG
>> Check power supply circuit and 10A fuse [No. 12
located in the fuse block (J/B)]. Refer to
●
If fuse is OK, check harness for open circuit. Repair or replace if necessary.
●
If fuse is NG, check harness for short circuit and replace fuse.
Gauge indication
Refrigerant cycle
Probable cause
Corrective action
Low-pressure side sometimes
becomes negative.
●
Air conditioning system
does not function and does
not cyclically cool the com-
partment air.
●
The system constantly func-
tions for a certain period of
time after compressor is
stopped and restarted.
Refrigerant does not dis-
charge cyclically.
↓
Moisture is frozen at expan-
sion valve outlet and inlet.
↓
Water is mixed with refriger-
ant.
●
Drain water from refrigerant
or replace refrigerant.
●
Replace liquid tank.
AC354A
Gauge indication
Refrigerant cycle
Probable cause
Corrective action
Low-pressure side becomes nega-
tive.
Liquid tank or front/rear side of
expansion valve’s pipe is
frosted or wet with dew.
High-pressure side is closed
and refrigerant does not flow.
↓
Expansion valve or liquid tank
is frosted.
Leave the system at rest until
no frost is present. Start it
again to check whether or not
the malfunction is caused by
water or foreign particles.
●
If water is the cause, initially
cooling is okay. Then the
water freezes causing a
blockage. Drain water from
refrigerant or replace refrig-
erant.
●
If due to foreign particles,
remove expansion valve
and remove the particles
with dry and compressed air
(not shop air).
●
If either of the above meth-
ods cannot correct the mal-
function, replace expansion
valve.
●
Replace liquid tank.
●
Check lubricant for contami-
nation.
AC362A
3 – Ground
: Battery voltage
RJIA1553E
ATC-96
TROUBLE DIAGNOSIS
2.
CHECK ECV CONTROL SIGNAL
1.
Turn ignition switch OFF.
2.
Reconnect compressor (ECV) connector.
3.
Perform self-diagnosis. Refer to
.
4.
Set in self-diagnosis STEP-4 (Code No. 45). Refer to
"FUNCTION CONFIRMATION PROCEDURE"
5.
Confirm ECV control signal between display and A/C auto amp.
harness connector M31 terminal 27 and ground using an oscillo-
scope.
OK or NG
OK
>> Replace compressor.
NG
>> GO TO 3.
3.
CHECK CIRCUIT CONTINUITY BETWEEN ECV AND DISPLAY AND A/C AUTO AMP.
1.
Turn ignition switch OFF.
2.
Disconnect compressor (ECV) and display and A/C auto amp.
connector.
3.
Check continuity between compressor (ECV) harness connector
F34 terminal 2 and display and A/C auto amp. harness connec-
tor M31 terminal 27.
OK or NG
OK
>> GO TO 4.
NG
>> Repair harness or connector.
4.
CHECK ECV
Check continuity between compressor (ECV) connector F34 termi-
nals 2 and 3.
OK or NG
OK
>> Replace display and A/C auto amp.
NG
>> Replace compressor.
RJIA3521E
SJIA1765E
2 – 27
: Continuity should exist.
RJIA3522E
2 – 3
: Continuity should exist.
RJIA3523E
TROUBLE DIAGNOSIS
ATC-97
C
D
E
F
G
H
I
K
L
M
A
B
ATC
Insufficient Heating
NJS0003M
SYMPTOM: Insufficient heating
INSPECTION FLOW
*1
*2
ATC-52, "FUNCTION CONFIRMA-
TION PROCEDURE"
, see No. 1.
*3
ATC-52, "FUNCTION CONFIRMATION
PROCEDURE"
, see No. 5 to 7.
*4
ATC-71, "Air Mix Door Motor Circuit"
*5
ATC-52, "FUNCTION CONFIRMA-
TION PROCEDURE"
, see No. 14.
*6
*7
ATC-77, "Blower Motor Circuit"
*8
ATC-71, "Air Mix Door Motor Circuit"
*9
EC-227, "DTC P0117, P0118 ECT SEN-
SOR"
*10
CO-10, "Changing Engine Coolant"
*11
CO-15, "Checking Radiator Cap"
RJIA3524E
ATC-98
TROUBLE DIAGNOSIS
Noise
NJS0003N
SYMPTOM: Noise
INSPECTION FLOW
*1
.
*2
Compressor clutch,
*3
ATC-25, "Maintenance of Lubricant
Quantity in Compressor"
*4
*5
RJIA3108E