Volkswagen Golf / Golf GTI / Jetta. Manual — part 168
01-214
Evaluating display groups 22 to 24, display zones 3 and 4 - Ignition timing
retardation cyl. 1 to 6
Appears on
display
Possible cause
Corrective action
All cylinders
between
8.0...15.0 CA
and at the same
display values
Knock sensor
faulty
Connector
corroded
- Check knock sensors
Page 28-30
Knock sensor
incorrectly
tightened
- Loosen knock sensor and tighten to
20 Nm
Accessories on
engine loose
- Tighten accessories
Poor fuel quality
- Change type of fuel
One cylinder
deviates greatly from
the others
Connector
corroded
- Check knock sensors
Page 28-30
Engine damaged
Repair Manual, 2.8 Liter VR6 4V
Engine Mechanical, Engine Code(s):
BDF; Repair Group 15
- Check compression pressures:
Accessories on
engine loose
- Tighten accessories
Measured value (data) blocks
01-215
Display group 28 - Ignition - Knock control
Control module in function "04-Basic setting"
Vehicle stationary, engine running at increased idle speed (only with brake and
accelerator pedals depressed)
System in basic
setting 28
Indicated on display
xxxx
rpm
xxx.x
%
xxx.x
C
Text
1
2
3
4
Display zones
Specification
Evaluation
Result of knock control
diagnosis
(Test ON / Test OFF /
Sys. OK. / Sys. n.OK.)
Syst. OK.
---
Engine coolant temperature
85.0...110.0
C
Page 01-
195
Engine load
12.0...100.0 %
---
Engine speed
Approx. 2300
rpm
---
Measured value (data) blocks
01-216
Measured value blocks, display groups 30...33, 99 - Oxygen Sensor (O2S)
control, evaluating
Display group 30 - Oxygen Sensor (O2S) control
Engine running at idle
Read measured value
block 30
Indicated on display
xxx
xxx
---
---
1
2
3
4
Display zones
Specification Evaluation
No display
---
---
No display
---
---
Oxygen Sensor (O2S) control status after
Three Way Catalytic Converter (TWC)
Three Way Catalytic Converter
(TWC) temperature at least 380.0
C (
display group 34, display zone
2)
111
Page 01-
217
Oxygen Sensor (O2S) control status before
Three Way Catalytic Converter (TWC)
Three Way Catalytic Converter (TWC)
temperature at least 380.0 C (
display
group 34, display zone 2)
111
Page 01-
217
Note on display zone 2:
The 3rd character in the digit number block will not be set to 1 until in part load range.
Measured value (data) blocks
01-217
Significance of characters in 3 digit number block, display zones 1 and 2 - Status
of Oxygen Sensor (O2S) control before and after Three Way Catalytic Converter
(TWC)
Significance if display = 1
1 2 3
Significance
1 Oxygen Sensor (O2S) control active
1
Oxygen Sensor (O2S) operationally ready
1
Oxygen Sensor (O2S) heating on
Note:
Depending on the status of the Oxygen Sensor (O2S) control, 0 or 1 may appear
alternately in the 3 digit block, but the Oxygen Sensor (O2S) must always be
operationally ready.
The 1 set for the Oxygen Sensor (O2S) heating may sporadically be 0 because the
heating is pulsed.
Measured value (data) blocks