Volkswagen Golf / Golf GTI / Jetta. Manual — part 1030
2)
Distance impulse number is a constant used to
calculate speed indication and distance travelled.
Code for USA/CDN Golf/Jetta is always 2.
Distance impulse number can only be
read/confirmed using function 10, "Adaptation"
Page 01-43
.
Instrument cluster through m.y. 1999, On Board Diagnostic (OBD)
13/2/2005
01-33
Read Measuring Value Block (function
08)
Use this function to observe various instrument
cluster inputs.
The measuring value block is divided into 4
display groups, each containing 4 display fields.
- Connect VAG 1551, select operating mode 1
"Rapid data transfer", switch on ignition and
enter address word 17 "instrument cluster".
- Press -Q- button to confirm input.
- Press
button until "Select function"is
displayed.
Rapid data transfer
HELP
Select function XX
Indicated on display:
- Press buttons -0- and -8- to select "Read
Measuring Value Block" function 08.
Rapid data transfer Q
08 - Read Measuring Value Block
Indicated on display:
- Press -Q- button to confirm input.
Read Measuring Value Block HELP
Enter display group number XXX
Indicated on display:
- Using the Scan Tool (ST) button pad, enter the
required display group number (following
example shows display group 001).
- Press -Q- button to confirm input.
Read Measuring Value Block 1
1
2
3
4
Indicated on display: (1...4
Display fields)
Instrument cluster through m.y. 1999, On Board Diagnostic (OBD)
13/2/2005
01-34
Notes:
Interpreting display groups and evaluating
measured values in individual display fields
tables beginning
Page 01-35
.
With the printer switched on, the information on
the display is printed out.
To easily change between display groups,
proceed as follows:
Display
group
VAG 1551
VAG 1552
Higher
Press button
3
Press
button
Lower
Press button
1
Press
button
Skip
Press button
C
Press button
C
- Displayed after pressing C button.
Read Measuring Value Block HELP
Enter display group number XXX
Indicated on display:
Notes:
- Enter alternate display group number as needed
tables beginning
Page 01-35
.
Display fields always show actual values
transmitted from senders and sensors.
However, instrument cluster display values can
differ from those in the display fields due to
internal filtering.
Other display groups are possible, but are not
required for On Board Diagnostic program!
Instrument cluster through m.y. 1999, On Board Diagnostic (OBD)
13/2/2005
01-35
Display groups, interpreting
Display group 001
Read Measuring
Value Block 1
Indicated on
display
xxx
xxx
xxx xxx
1
2
3
4
Display
fields
Designation
Evaluating
display fields
Time
Clock time in hours
and minutes
Page 01-36
Oil pressure switch
0.9 bar
Oilp2<min
Oilp2 OK.
Engine speed (RPM)
Engine speed in rpm
Speed
Speed in km/h
Instrument cluster through m.y. 1999, On Board Diagnostic (OBD)