Volkswagen Golf / Golf GTI / Jetta. Manual — part 929

01-53

Display

group

number

Display

field

Designation

4

Footwell/defroster flap
motor -V85-

Flap position: air flow to
defroster vents.

Codes 0 to 4: -V85-
malfunctioning.

Codes 5 to 100: -V85- OK,
provided basic setting
(function 04) was
completed.

Codes 101 to 255: -V85-
malfunctioning)

005

1

AIr flow flap motor -V71-

Measured value codes: 0
to 255

(Permissible deviation
from specification 2)

2

AIr flow flap motor -V71-

Specification: 0 to 255

Continued on next page

Climatronic On Board Diagnostic (OBD) through m.y. 2001

13/2/2005

01-54

Display

group

number

Display

field

Designation

3

AIr flow flap motor -V71-

Flap stop: fresh air flow to
passenger compartment.

Codes 0 to 149: -V71-
malfunctioning.

Codes 150 to 250: -V71-
OK, provided basic setting
(function 04) was
completed.

Codes 251 to 255: -V71-
malfunctioning.

4

AIr flow flap motor -V71-

Flap position: recirculating
air flow in passenger
compartment.

Codes 0 to 4: -V71-
malfunctioning.

Codes 5 to 100: -V71-
OK, provided basic setting
(function 04) was
completed.

Codes 101 to 255: -V71-
malfunctioning.

Continued on next page

Climatronic On Board Diagnostic (OBD) through m.y. 2001

13/2/2005

01-55

Display

group

number

Display

field

Designation

006

1

Value calculated by
Climatronic control module
-J255- in C as displayed
in A/C control head -E87-.

Value is calculated from
temperature measurement
at fresh air intake duct
temperature sensor -G89-
and outside air temperature
sensor -G17-.

Value is less than
measured value from -G17-
and -G89- when the vehicle
has just been parked.

A malfunction is not
present if the measured
values of temperature
sensors -G17- and -G89-
display actual values.

The values are almost
equal when driving over a
longer distance.

-G17- or -G89- are
malfunctioning if the values
are extremely abnormal.

Continued on next page

Climatronic On Board Diagnostic (OBD) through m.y. 2001

13/2/2005

01-56

Display

group

number

Display

field

Designation

2

Fresh air intake duct
temperature sensor -
G89-.

Actual measured value
in C.

3

Outside air temperature
sensor -G17-.

Actual measured value
in C.

4

Sunlight photo sensor
G107-.

Measured value in %,
from 0 to 120.

007

1

Sender for outlet
temperature, center -
G191-.

Actual measured value
in C.

2

Sender for outlet
temperature, floor outlet
-G192-.

Actual measured value
in C.

3

Instrument panel
interior temperature
sensor -G56-.

Actual measured value
in C.

4

Not applicable.

Continued on next page

Climatronic On Board Diagnostic (OBD) through m.y. 2001

13/2/2005